GPC140-15G

GPC140-15G Datasheet


GPC140 Commercial/GPM140 Medical 140 Watt Global Performance Switchers

Part Datasheet
GPC140-15G GPC140-15G GPC140-15G (pdf)
Related Parts Information
GPC140-12 GPC140-12 GPC140-12
GPC140-15 GPC140-15 GPC140-15
GPC140-24 GPC140-24 GPC140-24
GPC140-28 GPC140-28 GPC140-28
GPC140-24G GPC140-24G GPC140-24G
GPC140-5G GPC140-5G GPC140-5G
GPC140-12G GPC140-12G GPC140-12G
GPC140-28G GPC140-28G GPC140-28G
PDF Datasheet Preview
GPC140 Commercial/GPM140 Medical 140 Watt Global Performance Switchers

FEATURES:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22 Class B Commercial models and CISPR 11 Class B Medical models
• Single outputs
• Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3
• Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601
marked to LVD

SPECIFICATIONS:

Ac Input 85-264 Vac, 47-63 Hz single phase.

Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load A

Hold-Up Time 20ms minimum from loss of ac input at full load, nominal line 115 Vac .

Output Power 140 W convection 160 W with air flow. Peak ratings are for 60 s maximum duration, 10% duty cycle.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on output Recovery after fault is automatic.

Overvoltage Protection Main outputs 130% ± 15% typical.

Efficiency 70% at full rated load, nominal input voltage, depending on model and load distribution.

Input Protection Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.

Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 60 A.

Temperature Coefficient 0.03%/°C typical on all outputs.

Thermal Shutdown Provided as a standard feature. Designed to protect unit from prolonged overtemperature.

Environmental Designed for 0 to 50°C operation at full rated output power derate output current and total output power by per °C above 50°C. See Environmental and Packaging Specifications on next page.

Power Fail TTL- or CMOS-compatible output goes low < V 5 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are available to the user through adjustment of built-in potentiometer.

Output Noise rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Transient Response Main µs typical response time for return to within of final value for a 50% load step change. A/µs. Maximum voltage deviation is Startup/ shutdown overshoot less than

Remote Sense Provided as a standard feature.

Voltage Adjustment Built-in potentiometer adjusts voltage

Overload Protection Factory set to begin power limiting at approximately 175 W.

EMI/EMC Compliance

All models include built-in EMI filtering to meet the
following emissions requirements:

EMI SPECIFICATIONS

COMPLIANCE LEVEL

Conducted Emissions GPC140 EN55022 Class B FCC Class B

Conducted Emissions GPM140 EN55011 Class B FCC Class B

Static Discharge

EN61000-4-2, 6 kV contact, 8 kV air

RF Field Susceptibility

EN61000-4-3, 3 V/meter

Fast Transients/Bursts

EN61000-4-4, 2 kV, 5 kHz