GNT30 MEDICAL SERIES SINGLE OUTPUT POWER SUPPLY
Part | Datasheet |
---|---|
![]() |
GNT30-12 (pdf) |
Related Parts | Information |
---|---|
![]() |
GNT30-24 |
![]() |
GNT30-15G |
![]() |
GNT30-28 |
![]() |
GNT30-24G |
![]() |
GNT30-28G |
![]() |
GNT30-48 |
![]() |
GNT30-5 |
![]() |
GNT30-48G |
![]() |
GNT30-15 |
![]() |
GNT30-5G |
![]() |
GNT30-12G |
PDF Datasheet Preview |
---|
GNT30 MEDICAL SERIES SINGLE OUTPUT POWER SUPPLY Low Power Medical Power Supplies 30 Watt AC/DC Universal Input Power Supply • 90-264 Vac input range • Overvoltage and short circuit protection • Approved to UL, CSA and EN Standards • Small 50 mm x 80 mm footprint • Class II input available G2T30 The GNT30 Series is a 30 W universal input AC/DC Power supply in a very small footprint. With the medical approvals the GNT30 is ideal for a variety of medical device applications including, small single board computers, battery charging, and running small motors, pumps, and solenoids. The series with full approval to EN60601-1 Standard improves design-in time, and reduces end system compliance costs. All specifications are typical at nominal input, full load at 25 OC unless otherwise stated SPECIFICATIONS OUPUT SPECIFICATIONS Output Power 150 l.f.m. airflow Total Regulation Turn-on time Transient response A/ms 50% load deviation Temperature Coefficient Overvoltage protection Short Circuit protection Power cycling 30 Watts max. See note 4 See table s max. max. dev. 1 ms recovery to 1% +/-0.03%/oC 125% +/-10% Yes INPUT SPECIFICATIONS Input Voltage range Universal input Input frequency Input surge current Ground Leakage current Input current Input fuse 132 Vac 60 Hz 120 Vac 230 Vac F1,F2 100-240 nom 90 - 264 max Vac 55 Hz +/- 10 Hz 32 A max. 100 mA 180 mA single fault A EMC INFORMATION Conducted emissions EN55011 Radiated emissions EN55011 Line freq. harmonics EN61000-3-2 Voltage fluctuations EN61000-3-3 ESD Air EN61000-4-2 ESD Contact EN61000-4-2 Level B Level A Complies 8 kV contact 6 kV air Radiated immunity Fast Transients EFT Line surge immunity Conducted immunity Power freq. mag. field Voltage dip immunity EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 3 V/m 2 kV 1 kV diff /2 kV cm 3 Vrms 3 A/m 5 cycles 40 % vnom Watts. |
More datasheets: AT29LV040A-15JU | 3UYC | 10106 | GNT30-24 | GNT30-15G | GNT30-28 | GNT30-24G | GNT30-28G | GNT30-48 | GNT30-5 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived GNT30-12 Datasheet file may be downloaded here without warranties.