GLC65 Commercial/GLM65 Medical
65 Watt Multiple Output Global Performance Switchers

MULTIPLE OUTPUT GLOBAL PERFORMANCE SWITCHERS

Summary:
• 65 Watt Wide Range Input
• High Efficiency Up to 90%
• Universal input 90-264 Vac
• 2-year warranty
• Also available in single outputs
• Conducted EMI complies with FCC Class B and

CISPR 22 Class B Commercial models and CISPR 11 Class B Medical models
• Exempt from line harmonics standard EN61000-3-2
• Commercial Approved to UL1950, CSA-C22.2 No. 950,
• Medical Approved to UL2601-1, CSA No. and EN60601-1• Medical Approved to UL2601-1, CSA No.
• RoHS Compliant G suffix
• marked to LVD

SPECIFICATIONS

Ac Input 90-264 Vac, 47-63 Hz single phase.

Output Power Total continuous output power is 60 W, 75 W peak for 60 s 10% duty cycle. Total continuous rating with 150 LFM of air is 70 W.

Input Current Units are exempt from input current harmonic requirements of EN61000-3-2 when output power is less than 62W. Maximum input current at minimum input voltage and output overload will be less than A.

Inrush Current Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A.

Input Protection Internal AC fuse provided on all units. Designed to blow only if a catastrophic failure occurs in the unit -- Fuse does not blow on short circuit or unsustained overload.

Holdup Time Output voltage stays within regulation for 20 ms from loss of ac input at 65 W load, from 120 Vac input.

Efficiency 80% minimum.

Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit and will automatically recover after removal of fault.

Overvoltage Protection Built in with firing point set. OVP firing reduces output to less than 50% of nominal voltage in less than 50 ms.

Output Noise rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply with load terminated with 1uF capacitor.

Transient Response Main Output - 500 us typical response time for return to within of final value for a 50% load step within the regulation limits of minimum and maximum load, A/us. Maximum voltage deviation is

Minimum Load No minimum load required on any output. However, regulation limits may be exceeded if extreme conditions are applied. Contact factory for assistance.

Temperature Coefficient 0.03%°C typical on all outputs.

Voltage Adjustment Units provided with one potentiometer capable of adjusting all 3 outputs a minimum of +/- 5% from nominal setting.

EMI / EMC Compliance All models include built-in EMI filtering to meet EMC requirements of IEC601-1-2.

PERFORMANCE

EMC STANDARD

Conducted Emissions GLC65 Conducted Emissions GLM65 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Conducted RF Susceptibility Voltage Sags & Surges Line Frequency Harmonics

EN55022 Class B FCC Class B EN55011 Class B FCC Class B EN61000-4-2, Level 3 EN61000-4-3, Level 3 EN61000-4-4, Level 3 EN61000-4-5, Level 3 EN61000-4-6, 3V, 80% EN61000-4-11 EN61000-3-2 Class A >62Wout

Exempt <62Wout

GLC65 Commercial - Safety SL Power Electronics Corp declares under our sole responsibility that all models are in conformity with the applicable requirements of EN60950 following the provisions of the Low Voltage Directive 73/23/EEC. All models are approved to UL1950 with no D3 deviations , CSA22.2 No. 950-95 3rd edition, Level 3, IEC950, EN60950. CB certificate available.

Commercial Leakage Current Less then 500 uA 120 Vac. Less then mA 240 Vac.

GLM65 Medical - Safety Approvals All models are certified to be in compliance with the applicable requirements of UL2601-1, CSA No. IEC 601-1 1988 , EN 60601-1:

Medical Leakage Current 80 uA under normal conditions 132 Vac 60 Hz . Maximum under single fault conditions 264 Vac 60 Hz is 180 uA.

All specifications are typical at nominal input, full load at 25OC unless otherwise stated