CD4024BC 7-Stage Ripple Carry Binary Counter

CD4024BC 7-Stage Ripple Carry Binary Counter

The CD4024BC is a 7-stage ripple-carry binary counter. Buffered outputs are externally available from stages 1 through The counter is reset to its logical “0” stage by a logical “1” on the reset input. The counter is advanced one count on the negative transition of each clock pulse.
s Wide supply voltage range 3.0V to 15V s High noise immunity VDD typ. s Low power TTL compatibility Fan out of 2 driving 74L
or 1 driving 74LS s High speed 12 MHz typ.
input pulse rate VDD − VSS = 10V s Fully static operation
Ordering Code:

Order Number Package Number

Package Description

CD4024BCM

M14A
14-Lead Small Outline Integrated Circuit SOIC , JEDEC MS-012, Narrow

CD4024BCN

N14A
14-Lead Plastic Dual-In-Line Package PDIP , JEDEC MS-001, Wide
Devices also available in Tape and Reel. Specify by appending the suffix letter “X” to the ordering code.

Connection Diagram

Top View
2002 Fairchild Semiconductor Corporation DS005957

CD4024BC

Logic Diagrams

Flip-flop logic 1 of 7 identical stages .

Block Diagram

Input Logic

CD4024BC

Absolute Maximum Ratings Note 1

Note 2

DC Supply Voltage VDD Input Voltage VIN Storage Temperature Range TS Power Dissipation PD

Dual-In-Line Small Outline Lead Temperature Soldering, 10 seconds TL
to +18 VDC to VDD VDC
−65°C to +150°C
700 mW 500 mW
260°C

Recommended Operating Conditions Note 1

DC Supply Voltage VDD
+3 to +15 VDC

Input Voltage VIN
0 to VDD VDC

Operating Temperature Range TA
−55°C to +125°C

Note 1 “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed, they are not meant to imply that the devices should be operated at these limits. The table of “Recommended Operating Conditions” and “Electrical Characteristics” provides conditions for actual device operation.

Note 2 VSS = 0V unless otherwise specified.

DC Electrical Characteristics Note 2

Parameter

Conditions

Quiescent Device Current

VDD = 5V

VDD = 10V

VDD = 15V

LOW Level Output Voltage
|lO|<1 µA

VDD = 5V

VDD = 10V

VDD = 15V

HIGH Level Output Voltage
|lO|<1 µA