The AT29BV010A is a 2.7-volt only in-system Flash Programmable and Erasable Read Only Memory Flash . Its 1 megabit of memory is organized as 131,072 words by 8 bits. Manufactured with Atmel’s advanced nonvolatile CMOS EEPROM technology, the device offers access times to 120 ns, and a low 54 mW power dissipation. When the device is deselected, the CMOS standby current is less than 40 µA. The device endurance is such that any sector can typically be written to in excess

Part Datasheet
AT29BV010A-15JI AT29BV010A-15JI AT29BV010A-15JI (pdf)
Related Parts Information
AT29BV010A-20JC AT29BV010A-20JC AT29BV010A-20JC
AT29BV010A-20TC AT29BV010A-20TC AT29BV010A-20TC
AT29BV010A-12TC AT29BV010A-12TC AT29BV010A-12TC
AT29BV010A-12TI AT29BV010A-12TI AT29BV010A-12TI
AT29BV010A-15JC AT29BV010A-15JC AT29BV010A-15JC
AT29BV010A-12JI AT29BV010A-12JI AT29BV010A-12JI
AT29BV010A-15TC AT29BV010A-15TC AT29BV010A-15TC
AT29BV010A-15TI AT29BV010A-15TI AT29BV010A-15TI
AT29BV010A-12JC AT29BV010A-12JC AT29BV010A-12JC
AT29BV010A-25JC AT29BV010A-25JC AT29BV010A-25JC
AT29BV010A-25JI AT29BV010A-25JI AT29BV010A-25JI
AT29BV010A-25TC AT29BV010A-25TC AT29BV010A-25TC
AT29BV010A-25TI AT29BV010A-25TI AT29BV010A-25TI
PDF Datasheet Preview
• Single Supply Voltage, Range 2.7V to 3.6V
• Single Supply for Read and Write
• Software Protected Programming
• Fast Read Access Time - 120 ns
• Low Power Dissipation
15 mA Active Current 40 µA CMOS Standby Current
• Sector Program Operation Single Cycle Reprogram Erase and Program 1024 Sectors 128 Bytes/Sector Internal Address and Data Latches for 128 Bytes
• Two 8K Bytes Boot Blocks with Lockout
• Fast Sector Program Cycle Time - 20 ms Max.
• Internal Program Control and Timer
• DATA Polling for End of Program Detection
• Typical Endurance > 10,000 Cycles
• CMOS and TTL Compatible Inputs and Outputs
• Commercial and Industrial Temperature Ranges

The AT29BV010A is a 2.7-volt only in-system Flash Programmable and Erasable Read Only Memory Flash . Its 1 megabit of memory is organized as 131,072 words by 8 bits. Manufactured with Atmel’s advanced nonvolatile CMOS EEPROM technology, the device offers access times to 120 ns, and a low 54 mW power dissipation. When the device is deselected, the CMOS standby current is less than 40 µA. The device endurance is such that any sector can typically be written to in excess
1-megabit 128K x 8 Single 2.7-volt Battery-Voltage Flash Memory

AT29BV010A

Pin Configurations

Pin Name A0 - A16

Function Addresses

CE OE WE I/O0 - I/O7

Chip Enable Output Enable Write Enable Data Inputs/Outputs

No Connect

PLCC Top View
4 A12 3 A15 2 A16 1 NC 32 VCC 31 WE 30 NC

A7 5 A6 6 A5 7 A4 8 A3 9 A2 10 A1 11 A0 12 I/O0 13
29 A14 28 A13 27 A8 26 A9 25 A11 24 OE 23 A10 22 CE 21 I/O7

TSOP Top View Type 1

A11 1 A9 2 A8 3

A13 4 A14 5 NC 6 WE 7 VCC 8 NC 9 A16 10 A15 11 A12 12

A7 13 A6 14 A5 15 A4 16
32 OE 31 A10 30 CE 29 I/O7 28 I/O6 27 I/O5 26 I/O4 25 I/O3 24 GND 23 I/O2 22 I/O1 21 I/O0 20 A0 19 A1 18 A2 17 A3

I/O1 14 I/O2 15 GND 16 I/O3 17 I/O4 18 I/O5 19 I/O6 20

Block Diagram
of 10,000 times. The programming algorithm is compatible with other devices in Atmel’s Low Voltage Flash family of products.

To allow for simple in-system reprogrammability, the AT29BV010A does not require high input voltages for programming. The device can be operated with a single 2.7V to 3.6V supply. Reading data out of the device is similar to reading from an EPROM. Reprogramming the AT29BV010A is performed on a sector basis 128 bytes of data are loaded into the device and then simultaneously programmed.

During a reprogram cycle, the address locations and 128 bytes of data are captured at microprocessor speed and internally latched, freeing the address and data bus for other operations. Following the initiation of a program cycle, the device will automatically erase the sector and then program the latched data using an internal control timer. The end of a program cycle can be detected by DATA polling of I/O7. Once the end of a program cycle has been detected, a new access for a read or program can begin.

Device Operation

READ The AT29BV010A is accessed like an EPROM. When CE and OE are low and WE is high, the data stored at the memory location determined by the address pins is asserted on the outputs. The outputs are put in the high impedance state whenever CE or OE is high. This dual-line control gives designers flexibility in preventing bus contention.

SOFTWARE DATA PROTECTION PROGRAMMING The AT29BV010A has 1024 individual sectors, each 128 bytes. Using the software data protection feature, byte loads are used to enter the 128 bytes of a sector to be programmed. The AT29BV010A can only be programmed or reprogrammed using the software data protection feature. The device is programmed on a sector basis. If a byte of data within the sector is to be changed, data for the entire 128-byte sector must be loaded into the device. The data in any byte that is not loaded during the programming of its sector will be indeterminate. The AT29BV010A automatically does a sector erase prior to loading the data into the sector. An erase command is not required.

Software data protection protects the device from inadvertent programming. A series of three program commands to specific addresses with specific data must be presented to the device before programming may occur. The same three program commands must begin each program operation. All software program commands must obey the sector program timing specifications. Power transitions will not reset the software data protection feature however, the software feature will guard against inadvertent program cycles during power transitions.
2 AT29BV010A

AT29BV010A

Any attempt to write to the device without the 3-byte command sequence will start the internal write timers. No data will be written to the device however, for the duration of tWC, a read operation will effectively be a polling operation.

After the software data protection’s 3-byte command code is given, a byte load is performed by applying a low pulse on the WE or CE input with CE or WE low respectively and OE high. The address is latched on the falling edge of CE or WE, whichever occurs last. The data is latched by the first rising edge of CE or WE.

The 128 bytes of data must be loaded into each sector. Any byte that is not loaded during the programming of its sector will be indeterminate. Once the bytes of a sector are loaded into the device, they are simultaneously programmed during the internal programming period. After the first data byte has been loaded into the device, successive bytes are entered in the same manner. Each new byte to be programmed must have its high to low transition on WE or CE within 150 µs of the low to high transition of WE or CE of the preceding byte. If a high to low transition is not detected within 150 µs of the last low to high transition, the load period will end and the internal programming period will start. A7 to A16 specify the sector address. The sector address must be valid during each high to low transition of WE or CE . A0 to A6 specify the byte address within the sector. The bytes may be loaded in any order sequential loading is not required.

HARDWARE DATA PROTECTION Hardware features protect against inadvertent programs to the AT29BV010A in the following ways a VCC sense if VCC is below 2.0V typical , the program function is inhibited b VCC power on delay once VCC has reached the VCC sense level, the device will automatically time out 10 ms typical before programming c Program inhibit holding any one of OE low, CE high or WE high inhibits program cycles and d Noise filter pulses of less than 15 ns typical on the WE or CE inputs will not initiate a program cycle.

INPUT LEVELS While operating with a 2.7V to 3.6V power supply, the address inputs and control inputs OE, CE and WE may be driven from 0 to 5.5V without adversely affecting the operation of the device. The I/O lines can only be driven from 0 to VCC + 0.6V.

PRODUCT IDENTIFICATION The product identification mode identifies the device and manufacturer as Atmel. It may be accessed by hardware or software operation. The hardware operation mode can be used by an external programmer to identify the correct programming algorithm for the Atmel product. In addition, users may wish to use the software product identification mode to identify the part i.e., using the device code , and have the system software use the appropriate sector size for program operations. In this manner, the user can have a common board design for 256K to 4-megabit densities and, with each density’s sector size in a memory map, have the system software apply the appropriate sector size.

For details, see Operating Modes for hardware operation or Software Product Identification. The manufacturer and device code is the same for both methods of identification.

DATA POLLING The AT29BV010A features DATA polling to indicate the end of a program cycle. During a program cycle an attempted read of the last byte loaded will result in the complement of the loaded data on I/O7. Once the program cycle has been completed, true data is valid on all outputs and the next cycle may begin. DATA polling may begin at any time during the program cycle.

TOGGLE BIT In addition to DATA polling the AT29BV010A provides another method for determining the end of a program or erase cycle. During a program or erase operation, successive attempts to read data from the device will result in I/O6 toggling between one and zero. Once the program cycle has completed, I/O6 will stop toggling
and valid data will be read. Examining the toggle bit may begin at any time during a program cycle.
Ordering Information
tACC

ICC mA

Active

Standby
Ordering Code AT29BV010A-12JC AT29BV010A-12TC AT29BV010A-12JI AT29BV010A-12TI AT29BV010A-15JC AT29BV010A-15TC AT29BV010A-15JI AT29BV010A-15TI AT29BV010A-20JC AT29BV010A-20TC AT29BV010A-25JC AT29BV010A-25TC AT29BV010A-25JI AT29BV010A-25TI AT29BV010A-30JC AT29BV010A-30TC AT29BV010A-30JI AT29BV010A-30TI

Note:

Not recommended for New Designs.

Package 32J 32T 32J 32T 32J 32T 32J 32T 32J 32T 32J 32T 32J 32T 32J 32T 32J 32T

Operation Range

Commercial 0° to 70°C

Industrial -40° to 85°C Commercial 0° to 70°C

Industrial -40° to 85°C Commercial 0° to 70°C Commercial 0° to 70°C

Industrial -40° to 85°C Commercial 0° to 70°C

Industrial -40° to 85°C

Package Type
32-lead, Plastic J-leaded Chip Carrier PLCC
32-lead, Thin Small Outline Package TSOP
12 AT29BV010A

Packaging Information
32J PLCC

AT29BV010A

PIN NO. 1 IDENTIFIER
e D1 D

B1 E2

A2 A1 A
0.51 0.020 MAX 3X

COMMON DIMENSIONS Unit of Measure = mm

This package conforms to JEDEC reference MS-016, Variation AE. Dimensions D1 and E1 do not include mold protrusion.

Allowable protrusion is mm per side. Dimension D1 and E1 include mold mismatch and are measured at the extreme material condition at the upper or lower parting line. Lead coplanarity is mm maximum.

SYMBOL MIN NOM MAX NOTE

Note 2

Note 2
10/04/01

TITLE 2325 Orchard Parkway 32J, 32-lead, Plastic J-leaded Chip Carrier PLCC R San Jose, CA 95131
32T TSOP

PIN 1
0º ~ 8º c

Pin 1 Identifier

SEATING PLANE

GAGE PLANE

This package conforms to JEDEC reference MO-142, Variation BD. Dimensions D1 and E do not include mold protrusion. Allowable
protrusion on E is mm per side and on D1 is mm per side. Lead coplanarity is mm maximum.

COMMON DIMENSIONS Unit of Measure = mm

SYMBOL A A1 A2 D D1 E L L1 b c e

MIN NOM MAX