KLDR17.5T

KLDR17.5T Datasheet


Compared to other UL Listed fuses, Class CC fuses are the most current limiting, rating for rating. Because they are physically compact, they provide this superior protection in a fraction of the space required by other fuse classes. For example, when 600V three-pole, 30 ampere Class R fuse blocks are replaced by Littelfuse Class CC fuse blocks, panel mounting space is reduced approximately This is especially important when a panel contains many fuses to protect multiple circuit components. APPLICATIONS Three Types of Class CC Fuses, Specifically Designed to Protect Different Types of Components 1 Motor protection CCMR series dual-element, timedelay fuses specifically designed to protect motor circuits up to 40 HP**. 2 Small transformer protection control power transformers KLDR series, time-delay fuses designed to withstand the high magnetizing inrush of transformers. 3 General purpose protection of equipment requiring fast overload protection KLKR series, fast-acting fuses used for protection of equipment containing solidstate devices or other electronic components requiring fast response on overloads. SAFETY s 200,000 A.I.R. Reliable interruption of all overcurrents up

Part Datasheet
KLDR17.5T KLDR17.5T KLDR17.5T (pdf)
Related Parts Information
KLDR.125T KLDR.125T KLDR.125T
KLDR.500T KLDR.500T KLDR.500T
KLDR.250T KLDR.250T KLDR.250T
KLDR.200T KLDR.200T KLDR.200T
KLDR.300T KLDR.300T KLDR.300T
KLDR.150T KLDR.150T KLDR.150T
KLDR.800T KLDR.800T KLDR.800T
KLDR.187T KLDR.187T KLDR.187T
KLDR.100T KLDR.100T KLDR.100T
KLDR6.25T KLDR6.25T KLDR6.25T
KLDR2.25T KLDR2.25T KLDR2.25T
KLDR.400T KLDR.400T KLDR.400T
KLDR1.12T KLDR1.12T KLDR1.12T
KLDR.750T KLDR.750T KLDR.750T
KLDR.600T KLDR.600T KLDR.600T
KLDR1.25T KLDR1.25T KLDR1.25T
PDF Datasheet Preview
Class CC Fuses
600 VAC s 1/10 60 Amperes

Compared to other UL Listed fuses, Class CC fuses are the most current limiting, rating for rating. Because they are physically compact, they provide this superior protection in a fraction of the space required by other fuse classes. For example, when 600V three-pole, 30 ampere Class R fuse blocks are replaced by Littelfuse Class CC fuse blocks, panel mounting space is reduced approximately This is especially important when a panel contains many fuses to protect multiple circuit components. APPLICATIONS Three Types of Class CC Fuses, Specifically Designed to Protect Different Types of Components 1 Motor protection CCMR series dual-element, timedelay fuses specifically designed to protect motor circuits up to 40 HP**. 2 Small transformer protection control power transformers KLDR series, time-delay fuses designed to withstand the high magnetizing inrush of transformers. 3 General purpose protection of equipment requiring fast overload protection KLKR series, fast-acting fuses used for protection of equipment containing solidstate devices or other electronic components requiring fast response on overloads. SAFETY s 200,000 A.I.R. Reliable interruption of all overcurrents up
to 200,000 amperes. s Extremely current limiting Reduces damage caused by
heating and magnetic effects of short-circuit currents stops damaging short-circuit currents faster than any mechanical protective device. SPACE SAVING s Class CC fuses are the smallest 600V, 200,000 A.I.R. fuses approved for branch circuit protection. ECONOMICAL s Current limiting design often permits use of readily available, less costly equipment.
**Consult the Motor Protection Tables in the Fuseology section for specific motor sizing information

SPECIFICATIONS Voltage Ratings AC 600 Volts

DC 250 500 Volts CCMR † 300 Volts KLDR 300 Volts KLKR

Interrupting Ratings AC 200,000 amperes rms symmetrical

DC 20,000 amperes Ampere Range CCMR 2/10 60 amperes

KLDR 1/10 30 amperes KLKR 1/10 30 amperes Approvals AC Standard 248-4, Class CC UL Listed 1/10-30 Amps File No E81895 Standard 248, Class CD UL Listed 35-60 Amps File No E71611 CSA Certified 1/10-60 Amps File No LR29862 DC Littelfuse Self-certified

RECOMMENDED FUSE BLOCKS L60030C series L60060C series for CCMR

Refer to Fuse Block section of this catalog for additional information.
†Refer to the section for additional information.
0-30A
35-60A

REF.

Class CC Fuses
600 VAC s 1/10 60 Amperes

CCMR Series

For space-saving protection of motor circuits up to 40 HP**, we recommend Littelfuse CCMR series fuses. These fuses are the only true dual-element time-delay CC fuses specifically engineered for motor branch circuit protection. They provide Type II protection no damage to both NEMArated and the more sensitive IEC International Electromechanical Commission type motor circuit components.

CCMR series fuses are now available in larger sizes from 35 to 60 amperes! No other 600V fuse is available with this current carrying capacity in a package this small.
**Consult the Motor Protection Tables in the Fuseology section for specific motor sizing information

For more information on CCMR series Class CC fuses, see the CCMR series pages in the section of this catalog.
1/10 30A UL Listed Time-Delay Class CC
35 60A UL Listed Class CD

AMPERE RATINGS
10 35
12 40
15 45
20 60

Example part number series & amperage CCMR 30

KLDR Series

KLDR fuses are time-delay fuses specif- AMPERE RATINGS

Control Centers . When the time delay of KLDR fuses is adequate to carry motor starting current, they provide ex-

Example part number series &
amperage :

KLDR
cellent protection of motor branch cir-
cuits containing IEC or NEMA rated
motor controllers or contactors.
More datasheets: MAXREFDES121C# | ELI121-CRW | IXFN280N07 | KLDR.125T | KLDR.500T | KLDR.250T | KLDR.200T | KLDR.300T | KLDR.150T | KLDR.800T


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived KLDR17.5T Datasheet file may be downloaded here without warranties.

Datasheet ID: KLDR17.5T 646477