C6200 Generator Controller
Part | Datasheet |
---|---|
![]() |
C6200.0010 (pdf) |
Related Parts | Information |
---|---|
![]() |
C6200.0020 |
PDF Datasheet Preview |
---|
C6200 Generator Controller auxiliary functions • RS485 Modbus communication • CAN bus for optional user interface • Direct control of electronic governors • Increase/ decrease pulse outputs for speed and voltage control 29 30 31 AUX SUPPLY 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 CONTROL C/B PROT UNLOAD C/B LOAD CLOSE TRIP 54 55 56 58 59 60 61 62 63 64 65 66 67 PROGRAMMABLE OUTPUTS ANA OUT ALARM 12345678 C6200 GENCONTROLLER RS232 123456 SYNC BUSBAR VOLTAGE GENERATOR VOLTAGE GENERATOR CURRENT 7 8 9 10 11 12 13 14 12345678 RS485 CANBUS PROGRAMMABLE ANA PAR INPUTS IN LINES 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Figure Front of C6200 Application C6200 is a combined synchronizer and loadsharer for paralleling of generators. The unit can be used in any application where generator should run in parallel with each other or with the grid. For easy commissioning the unit includes a synchroscope on the front panel. 8 sets of programmable auxiliary inputs and outputs are available. They can be used for auxiliary functions like external commands for start synchronizing or load ramp functions. RS485 Modbus communication allows read out of the status of the unit or external control of the unit e.g. by a PLC. An analogue output can be used for indication of actual measurement values such as load or frequency of the generator. A User Interface Unit S6500 can be connected through CAN bus. Easy accessible modular connectors are furnished on the front side of the unit. Speed Control For synchronizing and active load sharing kW C6200 offers two sets of outputs for speed control: In case the engine is equipped with an electronic governor, the analogue outputs can be used for control of the speed. The output signal can be a voltage, current or PWM signal. It is possible to program the output signals regarding level and reference, so they can be adapted to virtually any governor in the market such as GAC or Woodward. In case it alternatively is desired to control the speed through a motorized potentiometer or the servomotor of a conventional governor a set of open collector outputs can be used. Voltage Control For voltage matching and reactive load sharing kVAr C6200 offers two sets of outputs for voltage control The Automatic Voltage Regulator AVR of the alternator can be controlled by an analogue signal voltage, current or PWM signal . It is possible to program the output signals regarding level and reference, so they can be adapted to virtually any AVR on the market. In case a motorized potentiometer shall be used for control of the AVR a set of open collector outputs can be used. The open collector outputs will then control relays which will control the motorized potentiometer. |
More datasheets: 9142083016 | 9142083017 | DBMY17W2PNMK52 | KSC2982DTF | KSC2982BTF | KSC2982ATF | KSC2982CTF | DCM-37P-L | MDM-21SCBR | C6200.0020 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived C6200.0010 Datasheet file may be downloaded here without warranties.