Laird Part Number 387000866
Part | Datasheet |
---|---|
![]() |
387000866 (pdf) |
PDF Datasheet Preview |
---|
Tunnel Series Thermoelectric Assembly Americas Europe Asia: The Tunnel Series thermoelectric assembly is a thermoelectric based air conditioner designed to temperature control small chambers used in analytical and medical diagnostic instruments. The unique design offers premium fans pushing air density heat sinks to minimize the number of air flow paths required to operate. The design utilizes custom thermoelectric modules to maximize cooling capacity with a high coefficient of performance. Moisture resistant insulation is used to keep condensation from penetrating the TEM cavity. The units operate on DC and are designed for an indoor lab use environment. Laird Part Number 387000866 • Compact form factor • Improved sealing for moisture protection • Reliable operation • RoHS compliant • Analytical storage compartment temperature control • Medical diagnostic chamber refrigeration SPECIFICATIONS TEA Model Heat Transfer, Cold Side Heat Transfer, Hot Side Cooling Power TEM Input Power Voltage, Nominal Current, Nominal Fan Input Power Voltage, Nominal Current, Nominal Dimension L x W x H Weight Operating Temperature Packaging DAT,029,12,02,00,00 Direct Air 29 W and Ta=35°C, Tolerance ± 10% 12 VDC Amps T=0°C 12 VDC Amps x 65 x mm 0.52kg to 50°C Individual cardboard box PERFORMANCE CURVES TEM module performance at Th = 35°C Qc vs dT dT °C ISOMETRIC DRAWINGS ELECTRICAL CONNECTIONS OBJECT TEM + TEM FAN HOT SIDE + FAN HOT SIDE WIRE TYPE AWG #20 COLOR Red Black White Green TERMINAL RECEPTICLE HOUSING TE Connectivity TE Connectivity POLE 1 2 3 4 PLUG HOUSING TE Connectivity INSTALLATION INSTRUCTIONS For operation below dew point, recommend to position unit in vertical direction with wires facing down to allow for condensation to run off of unit. Drip tray may be required to collect moisture from surfaces at temperatures below dew point. TE should not be used as part of the structure and is recommended to be protected from external forces. The input power to TEA should be protected with fuse. Fuse rating should withstand 150% of nominal current rating for 60 seconds. This is valid at Ta=35°C. Fuse ratings for other ambient temperatures x°C can be calculated with the formula I [x°C] = I This is valid when regulating with an On/Off regulation. At rapid temperature cycling where this is applicable, there can be a need for even higher fuse ratings. Max ripple current on supply power should be Switching power to TEMs at frequencies between 0.01Hz to 5KHz may degrade reliability and shorten life. SERVICE • Units are generally maintenance free, however occasionally it is recommended to clean the heat sinks and fans of debris. This is best done with compressed air. |
More datasheets: KSC1187OTA | KSC1187YBU | KSC1187OBU | KSC1187YTA | LX2205 EVAL KIT | RMDM-25SBS | BTS121ANKSA1 | BTS121AE3045ANTMA1 | MM74C73N | MIKROE-2649 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 387000866 Datasheet file may be downloaded here without warranties.