IDT72P51339 IDT72P51349 IDT72P51359 IDT72P51369
Part | Datasheet |
---|---|
![]() |
IDT72P51369L5BB8 (pdf) |
Related Parts | Information |
---|---|
![]() |
IDT72P51359L5BB |
![]() |
IDT72P51369L6BBI8 |
![]() |
IDT72P51369L6BBI |
![]() |
IDT72P51369L6BB8 |
![]() |
IDT72P51369L6BB |
![]() |
IDT72P51369L5BB |
![]() |
IDT72P51359L6BBI8 |
![]() |
IDT72P51359L6BBI |
![]() |
IDT72P51359L6BB8 |
![]() |
IDT72P51359L5BB8 |
![]() |
IDT72P51349L6BBI8 |
![]() |
IDT72P51349L6BBI |
![]() |
IDT72P51339L6BB8 |
![]() |
IDT72P51339L5BB |
![]() |
IDT72P51359L6BB |
![]() |
IDT72P51339L6BB |
![]() |
IDT72P51349L6BB8 |
![]() |
IDT72P51339L6BBI |
![]() |
IDT72P51339L6BBI8 |
![]() |
IDT72P51349L5BB8 |
![]() |
IDT72P51349L6BB |
![]() |
IDT72P51349L5BB |
![]() |
IDT72P51339L5BB8 |
PDF Datasheet Preview |
---|
1.8V MULTI-QUEUE FLOW-CONTROL DEVICES 8 QUEUES 36 BIT WIDE CONFIGURATION 589,824 bits 1,179,648 bits 2,359,296 bits 4,718,592 bits IDT72P51339 IDT72P51349 IDT72P51359 IDT72P51369 • Choose from among the following memory density options IDT72P51339 Total Available Memory = 589,824 bits IDT72P51349 Total Available Memory = 1,179,648 bits IDT72P51359 Total Available Memory = 2,359,296 bits IDT72P51369 Total Available Memory = 4,718,592 bits • Configurable from 1 to 8 Queues • Default configuration of 8 or 4 symmetrical queues • Default multi-queue device configurations IDT72P51339 2,048 x 36 x 8Q IDT72P51349 4,096 x 36 x 8Q IDT72P51359 8,192 x 36 x 8Q IDT72P51369 16,384 x 36 x 8Q • Default configuration can be augmented via the queue address bus • Number of queues and individual queue sizes may be configured at master reset though serial programming • 200 MHz High speed operation 5ns cycle time • 3.6ns access time • Independent Read and Write access per queue • User Selectable Bus Matching Options: FUNCTIONAL BLOCK DIAGRAM x36 in to x36 out x18 in to x36 out x9 in to x36 out x36in to x18out x18 in to x18 out x9 in to x18 out x36in to x9out x18 in to x9 out x9 in to x9 out • User selectable I/O 1.5V HSTL, 1.8V eHSTL, or 2.5V LVTTL • 100% Bus Utilization, Read and Write on every clock cycle • Selectable First Word Fall Through FWFT or IDT standard mode of operation • Ability to operate on packet or word boundaries • Mark and Re-Write operation • Mark and Re-Read operation • Individual, Active queue flags OR / EF, IR / FF, PAE, PAF, PR • 8 bit parallel flag status on both read and write ports • Direct or polled operation of flag status bus • Expansion of up to 64 queues and/or 32Mb logical configura- tion using up to 8 multi-queue devices in parallel • JTAG Functionality Boundary Scan • Available in a 256-pin PBGA, 1mm pitch, 17mm x 17mm • HIGH Performance submicron CMOS technology • Industrial temperature range -40°C to +85°C is available • Green parts available, see Ordering Information MULTI-QUEUE FLOW-CONTROL DEVICE WRITE CONTROL WADEN FSTR WRADD WEN 8 WCLK Din x36, 18 or x9 DATA IN FF/IR PAFn WRITE FLAGS IDT and the IDT logo are trademarks of Integrated Device Technology, Inc COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES 1 Integrated Device Technology, Inc. All rights reserved. Product specifications subject to change without notice. READ CONTROL RADEN ESTR RDADD 8 REN RCLK RCS Qout x36, x18 or x9 DATA OUT READ FLAGS EF/OR PR PAE PAEn 8 PRn 6716 drw01 AUGUST 2005 DSC-6716/3 IDT72P51339/72P51349/72P51359/72P51369 1.8V, MQ FLOW-CONTROL DEVICES 8 QUEUES 36 BIT WIDE CONFIGURATION 589, 824, 1,179,648, 2,359,296, and 4,718,592 COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES Table of Contents Features 1 Description 5 Pin configuration 7 Detailed Description 8 Pin Descriptions 10 Pin number table 16 Recommended DC operating conditions 17 Absolute maximum ratings 17 DC electrical characteristics 18 AC electrical characteristics 20 Functional description 22 Serial Programming 23 Default Programming 23 Parallel Programming 23 Queue Description 25 Configuration of the IDT Multi-queue flow-control device 25 Standard mode operation 26 Read Queue Selection and Read Operation 27 Switching Queues on the Write Port 29 Switching Queues on the Read Port 31 Flag Description 42 PAFn Flag Bus Operation 42 Full Flag Operation 42 Empty or Output Ready Flag Operation EF/OR 42 Almost Full Flag 43 Almost Empty Flag 43 Packet Ready Flag 47 Packet Mode Demarcation bits 49 JTAG Interface 82 JTAG AC electrical characteristics 86 Ordering Information 87 List of Tables Table 1 Device programming mode comparison 22 Table 2 Setting the queue programming mode during master reset 22 Table 3 Mode Configuration 25 Table 4 Write Address Bus, WRADD[7:0] 26 Table 5 Read Address Bus, RDADD[7:0] 27 Table 6 Write Queue Switch Operation 30 Table 7 Read Queue Switch Operation 32 Table 8 Same Queue Switch 32 Table 9 Flag operation boundaries and Timing 45 Table 10 Packet Mode Valid Byte for x36 bit word configuration 48 Table 11 Bus-Matching Set-Up 52 AUGUST 4, 2005 IDT72P51339/72P51349/72P51359/72P51369 1.8V, MQ FLOW-CONTROL DEVICES 8 QUEUES 36 BIT WIDE CONFIGURATION 589, 824, 1,179,648, 2,359,296, and 4,718,592 COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES List of Figures Figure Multi-Queue Flow-Control Device Block Diagram 6 Figure 2a. AC Test Load 19 Figure 2b. Lumped Capacitive Load, Typical Derating 19 Figure Reference Signals 22 Figure Device Programming Hierarchy 24 Figure IDT Standard mode illustrated Read Port 25 Figure First Word Fall Through FWFT mode illustrated Read Port 25 Figure Write Port Switching Queues Signal Sequence 29 Figure Switching Queues Bus Efficiency 29 Figure Simultaneous Queue Switching 30 Figure Read Port Switching Queues Signal Sequence 31 Figure Switching Queues Bus Efficiency 31 Figure Simultaneous Queue Switching 32 Figure MARK and Re-Write Sequence 33 Figure MARK and Re-Read Sequence 33 Figure MARKing a Queue in Packet Mode - Write Queue MARK 34 Figure MARKing a Queue in Packet Mode - Read Queue MARK 34 Figure UN-MARKing a Queue in Packet Mode - Write Queue UN-MARK 35 Figure UN-MARKing a Queue in Packet Mode - Read Queue UN-MARK 35 Figure MARKing a Queue in FIFO Mode - Write Queue MARK 37 Figure MARKing a Queue in FIFO Mode - Read Queue MARK 37 Figure UN-MARKing a Queue in FIFO Mode - Write Queue UN-MARK 38 Figure UN-MARKing a Queue in FIFO Mode - Read Queue UN-MARK 38 Figure Leaving a MARK active on the Write Port 39 Figure Leaving a MARK active on the Read Port 39 Figure Inactivating a MARK on the Write Port Active 40 Figure Inactivating a MARK on the Read Port Active 40 Figure 36bit to 36bit word configuration 49 Figure 36bit to 18bit word configuration 49 Figure 36bit to 9bit word configuration 49 Figure 18bit to 36bit word configuration 50 Figure 18bit to 18bit word configuration 50 Figure 18bit to 9bit word configuration 50 Figure 9bit to 36bit word configuration 51 Figure 9bit to 18bit word configuration 51 Figure 9bit to 9bit word configuration 51 Figure Bus-Matching Byte Arrangement 53 Figure Master Reset 54 Figure Default Programming 55 Figure Parallel Programming 56 Figure Queue Programming via Write Address Bus 57 Figure Queue Programming via Read Address Bus 57 Figure Serial Port Connection for Serial Programming 57 Figure Serial Programming 58 Figure Write Queue Select, Write Operation and Full Flag Operation 59 Figure Write Queue Select and Mark 60 Figure Write Operations in First Word Fall Through mode 61 Figure Full Flag Timing in Expansion Configuration 62 Figure Read Queue Select, Read Operation IDT mode 63 Figure Read Queue Select, Read Operation FWFT mode 64 Figure Read Queue Select and Mark IDT mode 65 Figure Output Ready Flag Timing In FWFT Mode 66 Figure Read Queue Selection with Read Operations IDT mode 67 Figure Read Queue Select, Read Operation and OE Timing 68 Figure Writing in Packet Mode during a Queue change 69 AUGUST 4, 2005 IDT72P51339/72P51349/72P51359/72P51369 1.8V, MQ FLOW-CONTROL DEVICES 8 QUEUES 36 BIT WIDE CONFIGURATION 589, 824, 1,179,648, 2,359,296, and 4,718,592 COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES List of Figures Continued Figure Reading in Packet Mode during a Queue change 70 Figure Writing Demarcation Bits Packet Mode 71 Figure Data Output Receive Packet Mode of Operation 72 Figure Almost Full Flag Timing and Queue Switch 73 Figure Almost Full Flag Timing 73 Figure Almost Empty Flag Timing and Queue Switch FWFT mode 74 Figure Almost Empty Flag Timing 74 Figure PAEn/PRn - Direct Mode - Status Word Selection 75 Figure PAFn - Direct Mode - Status Word Selection 75 Figure PAEn - Direct Mode, Flag Operation 76 Figure PAFn - Direct Mode, Flag Operation 77 Figure PAFn Bus - Polled Mode 78 Figure Expansion using ID codes 79 Figure Expansion using WCS/RCS 80 Figure Expansion Connection Read Chip Select RCS 81 Figure Expansion Connection Write Chip Select WCS 81 Figure Boundary Scan Architecture 82 Figure TAP Controller State Diagram 83 Figure Standard JTAG Timing 86 AUGUST 4, 2005 IDT72P51339/72P51349/72P51359/72P51369 1.8V, MQ FLOW-CONTROL DEVICES 8 QUEUES 36 BIT WIDE CONFIGURATION 589, 824, 1,179,648, 2,359,296, and 4,718,592 COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES The IDT72P51339/72P51349/72P51359/72P51369 multi-queue flow-control devices are single chips with up to 32 discrete configurable FIFO queues. All queues within the device have a common data input bus, write port and a common data output bus, read port . Data written into the write port is directed to a specific queue via an internal de-multiplex operation, addressed by the write address bus WRADD . Data read from the read port is accessed from a specific queue via an internal multiplex operation, addressed by the read address bus RDADD . Data writes and reads can be performed at high speeds up to 200MHz, with access times of 3.6ns. Data write and read operations are totally independent of each other, a queue maybe selected on the write port and a different queue on the read port or both ports may select the same queue simultaneously. The device provides Full flag and Empty flag status for the queue selected for write and read operations respectively. Also a Programmable Almost Full and Programmable Almost Empty flag for each queue is provided. Two 8 bit programmable flag busses are available, providing status of queues not selected for write or read operations. When 8 or less queues are configured in the device these flag busses provide an individual flag per queue, when more than 8 queues are used, either a Polled or Direct mode bus operation provides the flag busses with all queues status. Bus Matching is available on this device, either port can be 9 bits, 18 bits or 36 bits wide. When Bus Matching is used the device ensures the logical transfer of data throughput in a Little Endian manner. A packet mode of operation is also provided. Packet mode provides a packet ready flag output PR indicating when at least one or more packets of data within a queue is available for reading. The Packet Ready indicator is generated upon detection of the start and end of packet demarcation bits. The multi-queue device then provides the user with an internally generated packet ready status per queue. The user has full flexibility configuring queues within the device, being able to program the total number of queues between 1 and 32, the individual queue depths being independent of each other. The programmable flag positions are also user programmable. All programming is done via a dedicated serial port. If the user does not wish to program the multi-queue device, a default option is available that configures the device in a predetermined manner. A Master Reset must be provided to the device. A Master Reset latches in configuration/setup pins and must be performed before further programming of the device can take place. On the rising edge of master reset the device operating mode is set, the device programming mode serial, parallel or default is set and the expansion configuration device type master or slave is set. The multi-queue flow-control device has the capability of operating its I/O in either 2.5V LVTTL, 1.5V HSTL or 1.8V eHSTL mode. The type of I/O is selected via the IOSEL input. The core supply voltage VDD to the multi-queue is 1.8V, however the output levels can be set independently via a separate supply, VDDQ. A JTAG test port is provided, here the multi-queue flow-control device has a fully functional Boundary Scan feature, compliant with IEEE Standard Test Access Port and Boundary Scan Architecture. See Figure 1, Multi-Queue Flow-Control Device Block Diagram for an outline of the functional blocks within the device. AUGUST 4, 2005 IDT72P51339/72P51349/72P51359/72P51369 1.8V, MQ FLOW-CONTROL DEVICES 8 QUEUES 36 BIT WIDE CONFIGURATION 589, 824, 1,179,648, 2,359,296, and 4,718,592 COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES 8 WRADD WADEN WCLK WEN WCS ORDERING INFORMATION Device Type Power Speed Package G Process / Temperature Range BLANK I 1 Commercial 0°C to +70°C Industrial -40°C to +85°C Green Plastic Ball Grid Array PBGA, BB256-1 Commercial Only Clock Cycle Time tCLK Commercial and Industrial Speed in Nanoseconds Low Power 72P51339 589,824 bits 1.8V Multi-Queue Flow-Control Device 72P51349 1,179,648 bits 1.8V Multi-Queue Flow-Control Device 72P51359 2,359,296 bits 1.8V Multi-Queue Flow-Control Device 72P51369 4,718,592 bits 1.8V Multi-Queue Flow-Control Device 6716 drw79 NOTES Industrial temperature range product for the 6ns is available as a standard device. All other speed grades available by special order. Green parts are available. For specific speeds contact your sales office. DATASHEET DOCUMENT HISTORY 02/04/2005 08/01/2005 pg. pgs. 1, 3, 7, 9, 11, 13, 15, 17, 18, 20, 21, 25-28, 30-32, 45, 54-56, 58-66, 73, 74, 78, 80 and CORPORATE HEADQUARTERS 6024 Silver Creek Valley Road San Jose, CA 95138 for SALES 800-345-7015 or 408-284-8200 fax 408-284-2775 for Tech Support 408-360-1533 email: |
More datasheets: PB-1240-6SA0 | JNW350R41-18TZ | JNW350R631-18Z | JNW350R841-18TZ | BTS52352LAUMA1 | IDT72P51359L5BB | IDT72P51369L6BBI8 | IDT72P51369L6BBI | IDT72P51369L6BB8 | IDT72P51369L6BB |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived IDT72P51369L5BB8 Datasheet file may be downloaded here without warranties.