ST015PV2BPCF

ST015PV2BPCF Datasheet


Part Datasheet
ST015PV2BPCF ST015PV2BPCF ST015PV2BPCF (pdf)
Related Parts Information
ST006BG2SPRF ST006BG2SPRF ST006BG2SPRF
ST025PG1BPCF ST025PG1BPCF ST025PG1BPCF
ST050PG2BPCF ST050PG2BPCF ST050PG2BPCF
ST100PG1SPGF ST100PG1SPGF ST100PG1SPGF
ST005PG1SPCF ST005PG1SPCF ST005PG1SPCF
ST200PG1SPRF ST200PG1SPRF ST200PG1SPRF
ST100PG1SPRF ST100PG1SPRF ST100PG1SPRF
ST150PG2SPGF ST150PG2SPGF ST150PG2SPGF
ST100PG2BPGF ST100PG2BPGF ST100PG2BPGF
ST250PG1SPGF ST250PG1SPGF ST250PG1SPGF
ST250PG1SPRF ST250PG1SPRF ST250PG1SPRF
ST150PG2SPCF ST150PG2SPCF ST150PG2SPCF
ST150PG2BPRF ST150PG2BPRF ST150PG2BPRF
ST150PG2BPCF ST150PG2BPCF ST150PG2BPCF
ST150PG1SPGF ST150PG1SPGF ST150PG1SPGF
ST100PG2SPGF ST100PG2SPGF ST100PG2SPGF
ST100PG2BPCF ST100PG2BPCF ST100PG2BPCF
ST100PG1SPCF ST100PG1SPCF ST100PG1SPCF
ST025PG2BPCF ST025PG2BPCF ST025PG2BPCF
ST015PG2SPGF ST015PG2SPGF ST015PG2SPGF
ST005PG2SPGF ST005PG2SPGF ST005PG2SPGF
ST010PG2SPGF ST010PG2SPGF ST010PG2SPGF
ST250PG2BPCF ST250PG2BPCF ST250PG2BPCF
ST005PG2BPGF ST005PG2BPGF ST005PG2BPGF
ST005PG1SPGF ST005PG1SPGF ST005PG1SPGF
ST0R4BG1SPGF ST0R4BG1SPGF ST0R4BG1SPGF
ST015PG2BPCF ST015PG2BPCF ST015PG2BPCF
ST010BG2SPGF ST010BG2SPGF ST010BG2SPGF
PDF Datasheet Preview
Stainless Steel Pressure Sensors

ST Series

FEATURES
• Amplified output which

TYPICAL APPLICATIONS
• Pneumatic equipment
• Air compressors
• Air filtration monitoring
• Industrial controls

The Model ST pressure transducer combines Honeywell's proven silicon pressure sensing with the latest in ASIC technology in a rugged, industrial package. High value, coupled with outstanding performance, make this an ideal transducer for industrial control applications such as air compressors and pneumatic equipment. Temperature compensated, calibrated, and amplified, the ST has pressure ranges from 0 psi to psi to 0 psi to 250 psi.

The ST offers three standard output options for user flexibility, which are as follows a Vdc to Vdc ratiometric output from Vdc excitation, a Vdc to Vdc regulated output from Vdc to Vdc excitation, or a 4 mA to 20 mA output from Vdc to Vdc. The ST transducer delivers full scale accuracy BFSL over a wide temperature range of -40 °C to 100 °C [-40 °F to 212 °F] and utilizes a proven industry standard connector for high reliability.

WARNING

PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury.

WARNING

MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury.

Sensing and Control

Stainless Steel Pressure Sensors

ST Series

SPECIFICATIONS Pressure Ranges 1
psig 0 to 100, 150, 200, and 250
bar 0 to and Physical

Proof Pressure

Burst Pressure

Material in contact with media Weight Environmental 2
psi bar], 3 X rated range >150 psi bar], 2 X rated range psi bar], 5 X rated range >100 psi bar], 3 X rated range 300 series stainless steel or brass, internal seal, silicon, polyetherimide
oz gm]

Shock Vibration

Electrical 3
50 g’s peak [5 milliseconds]

Figure Curve AK, Table 514.2-V, Random Vibration Test [Overall g
rms = minimum]

Voltage

Current

Null Offset Span Excitation Ratiometric Regulated Supply Current Source nominal Sink nominal Supply Rejection Ratio Output Impedance Performance 3 Response Time EMI/RFI

Electrical Connection

Accuracy

Total Error Band

Compensated Operating and Storage Temperature Range

Vdc to Vdc] Vdc ±250 mV Vdc max.] Vdc to Vdc mA typical mA max.] mA 20 µA zero output 90 decibels 25 max.

MA 16 mA [4 mA to 20 mA] Vdc to Vdc

N/A N/A N/A N/A N/A
< 500 µs Exceeds CE heavy industrial [30v/m radiated 150 kHz to 1 gHz] Packard Metri-PackTM requires mating connector P/N3685901 order separately F.S.O. best fit straight line includes non-linearity, hysteresis, nonrepeatability. Thermal errors are not included. ±2% F.S.O. Includes zero offset error, span error, thermal effect on zero and thermal effect on span, non-linearity, hysteresis, non-repeatability Range -40 °C to 100 °C [-40 °F to 212 °F]

Contact the factory to discuss other pressure ranges. Meets IEC-68-2 or MIL-STD 810C. All specifications are measured at 25 °C [77 °F] and at rated excitation unless otherwise specified.
2 Honeywell
• Sensing and Control
More datasheets: ST025PG2BPCF | ST015PG2SPGF | ST005PG2SPGF | ST010PG2SPGF | ST250PG2BPCF | ST005PG2BPGF | ST005PG1SPGF | ST0R4BG1SPGF | ST015PG2BPCF | ST010BG2SPGF


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived ST015PV2BPCF Datasheet file may be downloaded here without warranties.

Datasheet ID: ST015PV2BPCF 636542