Part | Datasheet |
---|---|
![]() |
DC010NDC4 (pdf) |
Related Parts | Information |
---|---|
![]() |
DC030NDR5 |
![]() |
DC2R5BDR5 |
![]() |
DC010NGR5 |
![]() |
DC010NDR4 |
![]() |
DC010NGC4 |
![]() |
DC075BDR5 |
![]() |
DC001NDC4 |
![]() |
DC030NDC4 |
![]() |
DC2R5BDC4 |
![]() |
DC005NDC4 |
![]() |
DC002NDC4 |
PDF Datasheet Preview |
---|
Silicon Pressure Sensors Ultra Low Pressure Sensing DC Series FEATURES • Ultra Low Pressure Sensing, down to mBar • ASIC Technology • Available in Gage and Differential Pressure Ranges • Available in Ratiometric and Regulated • Temperature Compensated over 0 °C to 50°C [32 °F to 122 °F] • Combined Linearity and Hysteresis error < % Span TYPICAL APPLICATIONS • Medical Instrumentation • HVAC • Environmental Controls • Portable Monitors GENERAL DESCRIPTION The DC Series pressure sensors combine SURSENSE precision high sensitivity silicon sensing capabilities with the latest in Application Specific Integrated Circuitry ASIC technology to produce one of the most precise, reliable pressure sensors in the market. The SURSENSE technology provides Dynamic Self Compensation which substantially reduces offset errors due to changes in temperature, stability to warm up, long term instability and position sensitivity. When operated with an unregulated Vdc to Vdc supply the DC sensors provides a ratiometric to Vdc output Vdc span . WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Silicon Pressure Sensors Ultra Low Pressure Sensing DC Series ELECTRICAL SPECIFICATIONS Ouput Pressure Reference Excitation Vdc C4 Ratiometric R4 Regulated R5 Regulated Gage Differential Gage Differential Gage Differential 5 7 to 16 7 to 16 7 to 16 7 to 16 Offset 1 Voltage Vdc Output Span Vdc 4 ±2 4 ±2 5 Supply Current max. 4 mA 4 mA 8 mA 8 mA 8 mA 8 mA Output Source Current max. mA Output Sink Current null max. 20 uA 20 uA 20 uA 20 uA 20 uA 20 uA PERFORMANCE SPECIFICATIONS 2 Pressure Ranges in H2O 1 in H2O mBar 2 in H2O 5 mBar in H2O 5 in H2O 10 mBar 10 in H2O 25 mBar 20 in H2O 50 mBar 30 in H2O 75 mBar 140 cm H2O Overpressure 100 in H2O 100 in H2O 250 mBar 100 in H2O 250 mBar 100 in H2O 150 in H2O 375 mBar 150 in H2O 375 mBar 300 in H2O 750 mBar 450 in H2O 1125 mBar 1125 cm H2O Offset Position Sensitivity ±10 mV ±10 mV ±10 mV ±10 mV ±10 mV ±10 mV ±5 mV ±5 mV ±1 mV ±1 mV ±1 mV ±1 mV ±1 mV ±1 mV ±1 mV Total Error Typical % % % % % % % % % % % % % % % Total Error 3 Max. % % % % % % % % % % % % % % % Accuracy 4 |
More datasheets: NAND02GW3B2DZA6E | DC030NDR5 | DC2R5BDR5 | DC010NGR5 | DC010NDR4 | DC010NGC4 | DC075BDR5 | DC001NDC4 | DC030NDC4 | DC2R5BDC4 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived DC010NDC4 Datasheet file may be downloaded here without warranties.