DC002NDC4

DC002NDC4 Datasheet


Part Datasheet
DC002NDC4 DC002NDC4 DC002NDC4 (pdf)
Related Parts Information
DC030NDR5 DC030NDR5 DC030NDR5
DC2R5BDR5 DC2R5BDR5 DC2R5BDR5
DC010NGR5 DC010NGR5 DC010NGR5
DC010NDR4 DC010NDR4 DC010NDR4
DC010NGC4 DC010NGC4 DC010NGC4
DC075BDR5 DC075BDR5 DC075BDR5
DC001NDC4 DC001NDC4 DC001NDC4
DC030NDC4 DC030NDC4 DC030NDC4
DC2R5BDC4 DC2R5BDC4 DC2R5BDC4
DC010NDC4 DC010NDC4 DC010NDC4
DC005NDC4 DC005NDC4 DC005NDC4
PDF Datasheet Preview
Silicon Pressure Sensors Ultra Low Pressure Sensing

DC Series

FEATURES
• Ultra Low Pressure

Sensing, down to mBar
• ASIC Technology
• Available in Gage and Differential Pressure Ranges
• Available in Ratiometric and Regulated
• Temperature Compensated over 0 °C to 50°C [32 °F to 122 °F]
• Combined Linearity and Hysteresis error < % Span

TYPICAL APPLICATIONS
• Medical Instrumentation
• HVAC
• Environmental Controls
• Portable Monitors

GENERAL DESCRIPTION The DC Series pressure sensors combine SURSENSE precision high sensitivity silicon sensing capabilities with the latest in Application Specific Integrated Circuitry ASIC technology to produce one of the most precise, reliable pressure sensors in the market. The SURSENSE technology provides Dynamic Self Compensation which substantially reduces offset errors due to changes in temperature, stability to warm up, long term instability and position sensitivity.

When operated with an unregulated Vdc to Vdc supply the DC sensors provides a ratiometric to Vdc output Vdc span .

WARNING

PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury.

WARNING

MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Silicon Pressure Sensors Ultra Low Pressure Sensing

DC Series

ELECTRICAL SPECIFICATIONS

Ouput

Pressure Reference

Excitation Vdc

C4 Ratiometric R4 Regulated R5 Regulated

Gage Differential Gage Differential Gage Differential
5 7 to 16 7 to 16 7 to 16 7 to 16

Offset 1 Voltage Vdc

Output Span Vdc
4 ±2 4 ±2 5

Supply Current max.
4 mA 4 mA 8 mA 8 mA 8 mA 8 mA

Output Source Current max. mA

Output Sink Current null max.
20 uA 20 uA 20 uA 20 uA 20 uA 20 uA

PERFORMANCE SPECIFICATIONS 2

Pressure Ranges
in H2O 1 in H2O mBar 2 in H2O 5 mBar in H2O 5 in H2O 10 mBar 10 in H2O 25 mBar 20 in H2O 50 mBar 30 in H2O 75 mBar 140 cm H2O

Overpressure
100 in H2O 100 in H2O 250 mBar 100 in H2O 250 mBar 100 in H2O 150 in H2O 375 mBar 150 in H2O 375 mBar 300 in H2O 750 mBar 450 in H2O 1125 mBar 1125 cm H2O

Offset Position Sensitivity ±10 mV ±10 mV ±10 mV ±10 mV ±10 mV ±10 mV
±5 mV ±5 mV ±1 mV ±1 mV ±1 mV ±1 mV ±1 mV ±1 mV ±1 mV

Total Error Typical
% % % % % % % % % % % % % % %

Total Error 3 Max.
% % % % % % % % % % % % % % %

Accuracy 4
More datasheets: DC2R5BDR5 | DC010NGR5 | DC010NDR4 | DC010NGC4 | DC075BDR5 | DC001NDC4 | DC030NDC4 | DC2R5BDC4 | DC010NDC4 | DC005NDC4


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived DC002NDC4 Datasheet file may be downloaded here without warranties.

Datasheet ID: DC002NDC4 636437