MW005-Series Power Modules 36 Vdc to 75 Vdc Inputs 5 W
Part | Datasheet |
---|---|
![]() |
MW005BK (pdf) |
Related Parts | Information |
---|---|
![]() |
MW005C |
![]() |
MW005A |
![]() |
MW005B |
PDF Datasheet Preview |
---|
Data Sheet April 2008 MW005-Series Power Modules 36 Vdc to 75 Vdc Inputs 5 W The MW005-Series Power Modules use advanced surfacemount technology and deliver high-quality, efficient, and compact dc-dc conversion in a nonconductive case. n Telecommunications n Digital circuitry n Distributed power architecture Options n Standard long pins mm ± mm in. ± in. n Pin lengths mm ± mm in. ± in. n Small size mm x mm x mm in. x in. x in. n Wide input-voltage range 36 Vdc to 75 Vdc n Load regulation max MW005A, B, C n Line regulation max MW005A, B, C n Input-to-output isolation n No external filtering required n Operating ambient temperature range °C to +85 °C n PC-board mountable n High reliability n Overcurrent protection, unlimited duration n Output overvoltage protection n UL* 1950 Recognized, CSA† C22.2 No. 950-95 Certified, VDE 0805 EN60950, IEC950 Licensed n CE mark meets 73/23/EEC and 93/68/EEC n Meets FCC and VDE Class B limits for radiated emissions * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Associa- tion. This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. The CE mark is placed on selected products. The MW005A, B, C, BK, and CL Power Modules are dc-dc converters that operate over a wide input-voltage range of 36 Vdc to 75 Vdc and provide precisely regulated dc outputs. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings of 5 W at typical full-load efficiencies of 82% 80% for the MW005A . The modules are encapsulated in nonconductive cases that mount on printed-circuit boards. In a natural convection environment, the modules are rated to full load at 70 °C with no heat sinking or external filtering. The modules can be used up to with derated output power with an external input capacitor with no external capacitor . MW005-Series Power Modules 36 Vdc to 75 Vdc Inputs 5 W Data Sheet April 2008 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Device Input Voltage: Continuous Transient 2 ms Operating Ambient Temperature 60 ft./min. natural convection Storage Temperature I/O Isolation Voltage VI, trans Tstg 80 100 85 100 500 Unit Vdc V °C °C Vdc Electrical Specifications Unless otherwise indicated, specifications apply to all devices over all operating input voltage, resistive load, and temperature conditions. Table Input Specifications Ordering Information Table Device Codes Input Voltage 36 V 36 V 36 V 36 V 36 V Output Voltage 5V 12 V 15 V ±12 V ±15 V Output Power Device Code MW005A MW005B MW005C MW005BK MW005CL Comcode 106233901 106233919 106233927 106233935 106233943 Optional features maybe ordered using device code suffixes shown below. Please contact your Group Account Manager or Application Engineer for pricing and availability of options. Table Device Options Option Standard long pins mm ± mm in. ± in. Pin lengths mm ± mm in. ± in. Device Code Suffix Lineage Power MW005-Series Power Modules 36 Vdc to 75 Vdc Inputs 5 W Notes Data Sheet April 2008 Lineage Power Data Sheet April 2008 Notes MW005-Series Power Modules 36 Vdc to 75 Vdc Inputs 5 W Lineage Power MW005-Series Power Modules 36 Vdc to 75 Vdc Inputs 5 W Data Sheet April 2008 A sia-Pacific Head qu art ers T el +65 6 41 6 4283 World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D riv e, Mes quite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower.co m Eu ro pe, M id dle-East an d Afric a He ad qu arters T el +49 8 9 6089 286 Ind ia Head qu arters T el +91 8 0 28411633 Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information. 2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Res er ved. April 2008 DS99-116EPS Replaces DS99-115EPS |
More datasheets: LTDL-TA16A | MK24-A-1 | FTL-1419-3D | LTL-4238 | KSC2233 | ICS953202BG | DDM-50P-M | DEMM9PEA101 | MW005C | MW005A |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived MW005BK Datasheet file may be downloaded here without warranties.