JFC050C, JFC075C, JFC100C Power Modules dc-dc Converters 18 to 36 Vdc Input 15 Vdc Output 50 W to 100 W
Part | Datasheet |
---|---|
![]() |
JFC100C1 (pdf) |
PDF Datasheet Preview |
---|
Data Sheet April 2008 JFC050C, JFC075C, JFC100C Power Modules dc-dc Converters 18 to 36 Vdc Input 15 Vdc Output 50 W to 100 W The JFC-Series Power Modules use advanced, surfacemount technology and deliver high-quality, efficient, compact dc-dc conversion. n Redundant and/or distributed power architectures n Workstations n Computer equipment n Communications equipment Options n Heat sinks available for extended operation n Choice of primary remote on/off logic configura- tions n Delayed current-limit shutdown The JFC-Series Power Modules are dc-dc converters that operate over an input voltage range of 18 Vdc to 36 Vdc and provide a precisely regulated dc output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 50 W to 100 W at typical full-load efficiencies of The sealed modules have metal baseplates for excellent thermal performance. Threaded-through holes are provided for easy mounting or adding a heat sink for high-temperature applications. Listed above are the enhanced features for convenience and flexibility in redundant and/or distributed power applications. n Small size mm x mm x mm in. x in. x in. n High power density n High efficiency 85% typical n Low output noise n Constant frequency n Metal baseplate n 2:1 input voltage range n Anti-rollback circuit n Overcurrent protection n Primary and secondary remote on/off n Remote sense n Output voltage set-point adjustment n Output overvoltage protection n Synchronization n Forced load sharing parallelable n Output current monitor n Current-limit set-point adjustment n Overtemperature protection n Power good signal n Thermal warning signal n Adjustable output voltage n Case ground pin n ISO* 9001 Certified manufacturing facilities n UL†1950 Recognized, C22.2 No. 950-95 Certified, and VDE 0805 EN60950, IEC950 Licensed * ISO is a registered trademark of the International Organization of Standardization. † UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Assn. JFC050C, JFC075C, JFC100C Power Modules dc-dc Converters 18 to 36 Vdc Input, 15 Vdc Output 50 W to 100 W Data Sheet April 2008 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Unit Input Voltage continuous I/O Isolation Voltage for 1 minute 1500 Operating Case Temperature See Thermal Considerations section. Storage Temperature Tstg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Table Input Specifications Parameter Operating Input Voltage Maximum Input Current VI = 0 V to 75 V IO = IO, max JFC050C JFC075C JFC100C See Figure Inrush Transient Input Reflected-ripple Current, Peak-to-peak 5 Hz to 20 MHz, 12 µH source impedance see Figure Input Ripple Rejection 120 Hz Unit II, max II, max II, max mAp-p Fusing Considerations CAUTION This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a maximum rating of 20 A see Safety Considerations section . Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information. The temperature at this location should not exceed 100 °C. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table. Although the maximum case temperature of the power modules is 100 °C, you can limit this temperature to a lower value for extremely high reliability. JFC050C, JFC075C, JFC100C Power Modules dc-dc Converters 18 to 36 Vdc Input, 15 Vdc Output 50 W to 100 W Data Sheet April 2008 Thermal Considerations continued Introduction continued For additional information regarding this module, refer to the Thermal Management JC-, JFC-, JW-, and JFWSeries 50 W to 150 W Board-Mounted Power Modules Technical Note TN97-008EPS . Heat Transfer Without Heat Sinks Increasing airflow over the module enhances the heat transfer via convection. Figure 19 shows the maximum power that can be dissipated by the module without exceeding the maximum case temperature versus local ambient temperature TA for natural convection through 4 m/s 800 ft./min. . Note that the natural convection condition was measured at m/s to m/s 10 ft./min. to 20 ft./min. however, systems in which this power module may be used typically generate a natural convection airflow rate of m/s 60 ft./min. due to other heat dissipating components in the system. The use of Figure 19 is shown in the following example. Example What is the minimum airflow necessary for a JFC100C operating at VI = 28 V, an output current of A, and a maximum ambient temperature of 40 °C? Solution Given VI = 28 V IO = A TA = 40 °C Determine PD Use Figure PD = W Determine airflow v Use Figure v = m/s 350 ft./min. POWER DISSIPATION, PD W m/ s800 ft./min m/ s700 ft./min m/ s600 ft./min m /5s00 ft./min m /4s00 ft./min m/ s300 ft./min m/ s200 ft./min m/ s100 ft./min m/s NAT. CONV. 20 ft./min. 0 10 20 30 40 50 60 70 80 90 100 LOCAL AMBIENT TEMPERATURE, TA 8-1150 C .a Figure Forced Convection Power Derating with No Heat Sink Either Orientation POWER DISSIPATION, PD W VI = 36 V VI = 28 V VI = 18 V OUTPUT CURRENT, IO A 8-1782 C Figure JFC050C Power Dissipation vs. Output Current at 25 °C Lineage Power Data Sheet April 2008 Ordering Information Table Device Codes Input Voltage 28 V 28 V 28 V 28 V 28 V 28 V Output Voltage V Output Power 50 W 75 W 100 W 50 W 75 W 100 W Remote On/Off Logic Negative Positive Device Code JFC050C1 JFC075C1 JFC100C1 JFC050C JFC075C JFC100C Data Sheet April 2008 Comcode TBD 108008947 TBD Optional features can be ordered using the suffixes shown in Table The suffixes follow the last letter of the device code and are placed in descending order. For example, the device codes for a JFC100C module with the following options are shown below: Positive logic Negative logic Negative logic and delayed current-limit shutdown JFC100C3 JFC100C31 JFC100C1 Table Device Options Option Negative remote on/off logic and no delayed current-limit shutdown Positive remote on/off logic and no delayed current-limit shutdown Negative remote on/off logic and delayed current-limit shutdown Suffix 31 3 1 Lineage Power JFC050C, JFC075C, JFC100C Power Modules dc-dc Converters 18 to 36 Vdc Input, 15 Vdc Output 50 W to 100 W Ordering Information continued Table Device Accessories Accessory 1/4 in. transverse kit heat sink, thermal pad, and screws 1/4 in. longitudinal kit heat sink, thermal pad, and screws 1/2 in. transverse kit heat sink, thermal pad, and screws 1/2 in. longitudinal kit heat sink, thermal pad, and screws 1 in. transverse kit heat sink, thermal pad, and screws 1 in. longitudinal kit heat sink, thermal pad, and screws 1/2 in. transverse kit heat sink, thermal pad, and screws 1/2 in. longitudinal kit heat sink, thermal pad, and screws Comcode 407243989 407243997 407244706 407244714 407244722 407244730 407244748 407244755 Dimensions are in millimeters and inches . Data Sheet April 2008 1/4 IN. 1/2 IN. 1 IN. 61 1/2 IN. 8-2832 C Figure Longitudinal Heat Sink 1/4 IN. 1/2 IN. 1 IN. 1/2 IN. Figure Transverse Heat Sink 8-2833 C A sia-Pacific Head qu art ers T el +65 6 41 6 4283 World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D riv e, Mesquite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower.co m Eu ro pe, M id dle-East an d Afric a He ad qu arters Tel +49 8 9 6089 286 Ind ia Head qu arters Tel +91 8 0 28411633 Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information. 2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Res er ved. April 2008 DS99-131EPS Replaces DS97-466EPS |
More datasheets: FST16230A | FST16230 | SD5610-001 | SD5600-001 | FTLX1441E2 | BSC883N03LSGATMA1 | DSP56L307EVM | DEMM9SZF225 | MIKROE-2453 | MIKROE-2575 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived JFC100C1 Datasheet file may be downloaded here without warranties.