Shelf J2007001 L014 CC109157657
Part | Datasheet |
---|---|
![]() |
J2007001L007A (pdf) |
Related Parts | Information |
---|---|
![]() |
J2007001L005 |
![]() |
J2007001L007 |
PDF Datasheet Preview |
---|
GE Critical Power Quick Start Guide CP Converter Shelf System Shelf J2007001 L014 CC109157657 DC input from left and right L015 150042727 DC input from left only Converters CP2000DC54PEZ CC109162104 CP2500DC54PEZ CC109170528 Controller CP841_3C3R CC109145331 No vertical spacing is required, allow a minimum 2 inch clearance at back of shelf for rectifier airflow. Refer to Compact Power Line CPL Brochure for details and accessories. Tools required: Wire cutters and strippers Cable crimpers Torque wrench - 0-65 in-lb 0-10Nm Sockets - 5/16”, 7/16, etc. Screwdrivers - Philips #1 and #2, Flat small Step 1 - Mount Shelf Reposition mounting ears as required - 8 screws each. Torque to 25 in-lb 2.8Nm - Phillips screwdriver. Attach shelf to the frame using a minimum of four screws two on each side - 12-24 provided . Torque to 35 in-lb 4Nm - 5/16” socket. Step 3 - Connect -48V Output and Output Return Lugs - 1/4” on 5/8” centers not provided . Torque to 65 in-lb Nm - 7/16” socket. Step 4 - Connect DC Inputs • Feed each input from 80A breaker shelf rating limited Step 2 - Connect Chassis Ground Some applications may rely on frame mounting screws for shelf ground omitting the chassis ground cable. Minimum 6 AWG wire is recommended. Lugs - 1/4” on 5/8” centers not provided . Torque to 65 in-lb Nm - 7/16” socket. Lugs - 1/4” on 5/8” centers not provided . Torque to 65 in-lb Nm - 7/16” socket CAUTION Verify DC Input voltage and polarity with a voltmeter before proceeding. Note Input Feed Returns must be externally connected to DC Reference CO ground. Output Return Ground -48V Output DC Inputs - Converter Inputs 4 3 POS NEG NEG POS Chassis Ground L014 shown L015 has all DC input feeds from the right as viewed from the rear CP Converter Shelf - Quick Start Guide Document 850033106 r04 2015 April J4 1-Wire Battery Temp and Voltage Monitor J1 Alarms and Inputs - page 4 J5 LAN Port J2 External Alarm Inputs - page 4 RS-232 Craft port • Specifications and ordering information are in the Compact Power Line CPL Brochure available at • Equipment and subassembly ports are suitable for connection to intra-building or unexposed wiring or cabling; can be connected to shielded intra-building cabling grounded at both ends. • Grounding / Bonding Network Connect to an Isolated Ground Plane Isolated Bonding Network or an Integrated Ground Plane Mesh- Bonding Network or Common Bonding Network . • Installation Environment - Install in Network Telecommunication Facilities, OSP, or where NEC applies. • DC return may be either Isolated DC return DC-I or Common DC return DC-C . Reference Documents These documents are available at Document 850035894 CC848836981 Title Galaxy Pulsar Edge Quick Start Guide Galaxy Pulsar Edge Controller Family Product Manual Compact Power Line CPL Brochure GE ● 6C01PSChoilonhveRrdt.e●r SPhlaenlof,-TQX u75ic0k74St●ar1t-G8u88id-5e46-3243 Documewnwt 8w5.g0e0c3ri3ti1ca0l6powr0e4r.co2m015 April |
More datasheets: LTL-2H3VYKNT | LTL-2H3VFKNT | LTL-2H3VHKNT | LTL-2H3VAKNT | LTL-2P3VRKNT | MDM-21PH006P | HR30-6JB-6S | DBMAME25SF0 | J2007001L005 | J2007001L007 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived J2007001L007A Datasheet file may be downloaded here without warranties.