CLP0212 Open Frame Power Supply
Part | Datasheet |
---|---|
![]() |
CLP0212FPXX5Z03A (pdf) |
Related Parts | Information |
---|---|
![]() |
CLP0212FPEX3Z01A |
![]() |
CLP0212FPEX5Z03A |
![]() |
CLP0212FPEX5Z01A |
![]() |
CLP0212FPXX3Z01A |
![]() |
CLP0212FPXX5Z01A |
PDF Datasheet Preview |
---|
Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input 12Vdc output 200W Output Power • Telecommunications equipment • Embedded Computing • Storage Systems • Industrial equipment • Compact size mm x mm x mm 2 in x 4 in x in with density of 18W/in3 • Universal AC Input Range 90 264VAC • Output voltage of 12V adjustable ±5% • Maximum output current of 12Vout 200W • Standby output of 5V or 3.3V 0.25A • High efficiency with 80 Gold Certification • Full load capability at 50ºC and 1m/s 200LFM airflow with derating at higher temperatures or lower airflows • Remote ON/OFF • Output overcurrent protection non-latching • Overtemperature protection • Output overvoltage protection • Up to 12ms of holdup time • Parallellable with current sharing • Active power factor corrected input • Conducted EMI - meets CISPR22 EN55022 and FCC Class A requirements • Compliant to RoHS II EU “Directive 2011/65/EU” • UL and cUL approved to UL/CSA60950-1, TUV EN60950-1 , CE Mark for LVD and CB Report available • ISO** 9001 and ISO 14001 certified manufacturing facilities In a smal l 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energy efficiency. W i t h i t s m a l s i z e , t he CLP series is specifically designed to handle power challenges associated with tight space and low airflow. Offering a leading 18W/in3 power density in a 1U high, fan- less form factor, the CLP series addresses a broad range of applications in new products from communications, computing and data storage original equipment manufacturers OEMs . It delivers greater than 90 percent typical power efficiency and full load output at with higher temperature operation possible at derated output. The CLP series utilizes a unique design approach at this power level, leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction PFC circuits. Protection features include overcurrent OCP , overvoltage OVP , and overtemperature OTP . * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards February 14, 2017 2017 General Electric Company. All rights reserved. CLP0212 Open Frame Power Supply 90 - 264Vac input 12Vdc output 200W Output Power Data Sheet Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Unit Input Voltage - Continuous For up to 10 seconds max. Input Voltage Continuous CATV Powering trapezoidal waveform Note Output power is limited to 100W Operating Ambient Temperature see Thermal Considerations section CLP0212FPEX5Z01A, C CLP0212FPEX5Z02A CLP0212FPEX5Z03A, C in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 65W CLP0212FPEX5Z02A in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 110W CLP0212FPEX5Z03A, C Storage Temperature VRMS 55† 55† Humidity non-condensing Altitude 5000 Startup at -40ºC is limited to 80% of maximum load 160W for all versions, except the CLP0212FPEX5Z02A which can start up at full load. Ordering Information Please contact your GE Sales Representative for pricing, availability and optional features. Table Device Codes Device Code Input Voltage Range Output Voltage Output Current On/Off Control Standby Supply CLP0212FPXX5Z01A* 90 264Vac 12.0Vdc 16.7A Negative Logic Temperature Range -25 to 70ºC CLP0212FPXX3Z01A* 90 264Vac 12.0Vdc 16.7A Negative Logic -25 to 70ºC CLP0212FPEX5Z01A* 90 264Vac 12.0Vdc 16.7A Negative Logic -40 to 70ºC CLP0212FPEX5Z02A* 90 264Vac 12.0Vdc 8.34A Absent Not accessible -40 to 70ºC CLP0212FPEX5Z03A* 90 264Vac 12.0Vdc 16.7A Absent Not accessible -40 to 70ºC CLP0212FPXX5Z03A* 90 264Vac 12.0Vdc 16.7A Absent Not accessible -25 to 70ºC CLP0212FPEX5Z01C 90 264Vac 12.0Vdc 16.7A Negative Logic -40 to 70ºC CLP0212FPEX5Z03C 90 264Vac 12.0Vdc 16.7A Absent Not accessible -40 to 70ºC Comcode 150032000 150032001 150032002 150032003 150032004 150032005 150038518 150038520 * Not recommended for new designs Contact Us For more information, call us at USA/Canada +1 877 546 3243, or +1 972 244 9288 Asia-Pacific: Europe, Middle-East and Africa: GE Critical Power reserves the right to make changes to the product s or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product s or information. February 14, 2017 2017 General Electric Company. All International rights reserved. Version |
More datasheets: VGF0136AH | VGF0136AB | VGB0124AY7A | DBMMY25PF179 | RC1587T15 | RC1587T33 | RC1587T | SX15AD4 | DAM15SK52 | CLP0212FPEX3Z01A |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived CLP0212FPXX5Z03A Datasheet file may be downloaded here without warranties.