CLP0212FPEX5Z03A

CLP0212FPEX5Z03A Datasheet


CLP0212 Open Frame Power Supply

Part Datasheet
CLP0212FPEX5Z03A CLP0212FPEX5Z03A CLP0212FPEX5Z03A (pdf)
Related Parts Information
CLP0212FPEX3Z01A CLP0212FPEX3Z01A CLP0212FPEX3Z01A
CLP0212FPXX5Z03A CLP0212FPXX5Z03A CLP0212FPXX5Z03A
CLP0212FPEX5Z01A CLP0212FPEX5Z01A CLP0212FPEX5Z01A
CLP0212FPXX3Z01A CLP0212FPXX3Z01A CLP0212FPXX3Z01A
CLP0212FPXX5Z01A CLP0212FPXX5Z01A CLP0212FPXX5Z01A
PDF Datasheet Preview
Data Sheet

CLP0212 Open Frame Power Supply
90 - 264Vac input 12Vdc output 200W Output Power
• Telecommunications equipment
• Embedded Computing
• Storage Systems
• Industrial equipment
• Compact size mm x mm x mm 2 in x 4 in x in with density of 18W/in3
• Universal AC Input Range 90 264VAC
• Output voltage of 12V adjustable ±5%
• Maximum output current of 12Vout 200W
• Standby output of 5V or 3.3V 0.25A
• High efficiency with 80 Gold Certification
• Full load capability at 50ºC and 1m/s 200LFM airflow
with derating at higher temperatures or lower airflows
• Remote ON/OFF
• Output overcurrent protection non-latching
• Overtemperature protection
• Output overvoltage protection
• Up to 12ms of holdup time
• Parallellable with current sharing
• Active power factor corrected input
• Conducted EMI - meets CISPR22 EN55022 and FCC

Class A requirements
• Compliant to RoHS II EU “Directive 2011/65/EU”
• UL and cUL approved to UL/CSA60950-1, TUV

EN60950-1 , CE Mark for LVD and CB Report available
• ISO** 9001 and ISO 14001 certified manufacturing
facilities

In a smal l 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energy efficiency. W i t h i t s m a l s i z e , t he CLP series is specifically designed to handle power challenges associated with tight space and low airflow. Offering a leading 18W/in3 power density in a 1U high, fan- less form factor, the CLP series addresses a broad range of applications in new products from communications, computing and data storage original equipment manufacturers OEMs . It delivers greater than 90 percent typical power efficiency and full load output at with higher temperature operation possible at derated output. The CLP series utilizes a unique design approach at this power level, leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction PFC circuits. Protection features include overcurrent OCP , overvoltage OVP , and overtemperature OTP .
* UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards

February 14, 2017
2017 General Electric Company. All rights reserved.

CLP0212 Open Frame Power Supply
90 - 264Vac input 12Vdc output 200W Output Power

Data Sheet

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Device

Unit

Input Voltage - Continuous

For up to 10 seconds max.

Input Voltage Continuous CATV Powering trapezoidal waveform Note Output power is limited to 100W

Operating Ambient Temperature
see Thermal Considerations section

CLP0212FPEX5Z01A, C

CLP0212FPEX5Z02A CLP0212FPEX5Z03A, C
in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 65W

CLP0212FPEX5Z02A
in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 110W

CLP0212FPEX5Z03A, C

Storage Temperature

VRMS
55†
55†

Humidity non-condensing Altitude
5000

Startup at -40ºC is limited to 80% of maximum load 160W for all versions, except the CLP0212FPEX5Z02A which can start up at full load.
Ordering Information

Please contact your GE Sales Representative for pricing, availability and optional features.

Table Device Codes

Device Code

Input Voltage Range

Output Voltage

Output Current

On/Off Control

Standby Supply

CLP0212FPXX5Z01A* 90 264Vac 12.0Vdc 16.7A Negative Logic

Temperature Range
-25 to 70ºC

CLP0212FPXX3Z01A* 90 264Vac 12.0Vdc 16.7A Negative Logic -25 to 70ºC

CLP0212FPEX5Z01A* 90 264Vac 12.0Vdc 16.7A Negative Logic -40 to 70ºC

CLP0212FPEX5Z02A* 90 264Vac 12.0Vdc 8.34A

Absent

Not accessible -40 to 70ºC

CLP0212FPEX5Z03A* 90 264Vac 12.0Vdc 16.7A

Absent

Not accessible -40 to 70ºC

CLP0212FPXX5Z03A* 90 264Vac 12.0Vdc 16.7A

Absent

Not accessible -25 to 70ºC

CLP0212FPEX5Z01C 90 264Vac 12.0Vdc 16.7A Negative Logic -40 to 70ºC

CLP0212FPEX5Z03C 90 264Vac 12.0Vdc 16.7A

Absent

Not accessible -40 to 70ºC

Comcode 150032000 150032001 150032002 150032003 150032004 150032005 150038518 150038520
* Not recommended for new designs

Contact Us

For more information, call us at

USA/Canada +1 877 546 3243, or +1 972 244 9288

Asia-Pacific:

Europe, Middle-East and Africa:

GE Critical Power reserves the right to make changes to the product s or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product s or information.

February 14, 2017
2017 General Electric Company. All International rights reserved.

Version
More datasheets: VGF0136AB | VGB0124AY7A | DBMMY25PF179 | RC1587T15 | RC1587T33 | RC1587T | SX15AD4 | DAM15SK52 | CLP0212FPEX3Z01A | CLP0212FPXX5Z03A


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived CLP0212FPEX5Z03A Datasheet file may be downloaded here without warranties.

Datasheet ID: CLP0212FPEX5Z03A 645615