CC030-Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc Inputs, 30 W
Part | Datasheet |
---|---|
![]() |
CC030A-M (pdf) |
Related Parts | Information |
---|---|
![]() |
CC030C-M |
PDF Datasheet Preview |
---|
Data Sheet March 2008 CC030-Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc Inputs, 30 W The CC030-Series Power Modules use advanced, surfacemount technology and deliver high-quality, compact, dc-dc conversion at an economical price. Options n Choice of remote on/off logic configuration n Case ground pin n Short pins mm ± mm in. ± in. n Small size mm x mm x mm in. x in. x in. n Low output noise n Constant frequency n Industry-standard pinout n Metal case n 2:1 input voltage range n High efficiency 81% typical n Positive remote on/off logic n Remote sense n Adjustable output voltage 90% to 110% of VO, nom n UL* 1950 Recognized, CSA† C22.2 No. 950-95 Certified, 0805 EN60950, IEC950 Licensed n Within FCC Class A Radiated Limits n Distributed power architectures n Communication equipment n Computer equipment The CC030-Series Power Modules are dc-dc converters that operate over an input voltage range of 18 Vdc to 36 Vdc and provide precisely regulated outputs. The outputs are isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings of 30 W at a typical full-load efficiency of The power modules feature remote on/off, output sense both negative and positive leads , and output voltage adjustment from 90% to 110% of the nominal output voltage. For diskdrive applications, the CC030B Power Module provides a motor-start surge current of 3 A. The modules are PC board-mountable and encapsulated in metal cases. The modules are rated to full load at 100 °C case temperature. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. CC030-Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc Inputs, 30 W Data Sheet March 2008 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Unit Input Voltage continuous Operating Case Temperature See Thermal Considerations section. Storage Temperature Tstg I/O Isolation Voltage Continuous Transient 1 min Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Table Input Specifications Parameter Unit Operating Input Voltage Maximum Input Current VI = 0 V to 75 V IO = IO, max see Figure Inrush Transient II, max Input Reflected-Ripple Current, Peak-to-Peak Hz to 20 MHz, 12 source impedance see Figure 14 and Design Considerations. mAp-p Input Ripple Rejection 120 Hz Fusing Considerations CAUTION This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a maximum rating of 5 A in series with the input see Safety Considerations section . Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information. Lineage Power Data Sheet March 2008 Ordering Information For assistance with ordering options, contact your Lineage Power Account Manager or Field Application Engineer. Table Device Codes Input Voltage 24 V 24 V 24 V Output Voltage 5V 12 V 15 V Output Power 30 W 30 W 30 W Device Code Comcode 107587172 107587180 107587198 Table Device Options Option Short pins mm ± mm in. ± in. Case ground pin Negative Remote On/Off Comcode 8 Lineage Power CC030-Series Power Modules dc-dc Converters 18 Vdc to 36 Vdc Inputs, 30 W Data Sheet March 2008 A sia-Pacific Head qu art ers T el +65 6 41 6 4283 World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D riv e, Mesquite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower.co m Eu ro pe, M id dle-East an d Afric a He ad qu arters Tel +49 8 9 6089 286 Ind ia Head qu arters Tel +91 8 0 28411633 Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information. 2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Res er ved. March 2008 DS98-225EPS Replaces DS98-224EPS |
More datasheets: HER102-AP | HER104-AP | HER107-TP | HER102-TP | HER101-AP | HER108-AP | HER108-TP | HER103-AP | NAND08GW3D2AN6E | CC030C-M |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived CC030A-M Datasheet file may be downloaded here without warranties.