AXH010A0S0R9-SR
Part | Datasheet |
---|---|
![]() |
AXH010A0Y9-SRZ (pdf) |
Related Parts | Information |
---|---|
![]() |
AXH010A0Y93-SR |
![]() |
AXH010A0P93-SR |
![]() |
AXH010A0P9-SRZ |
![]() |
AXH010A0Y93-SRZ |
![]() |
AXH010A0Y-SR |
![]() |
AXH010A0Y-SRZ |
![]() |
AXH010A0P93-SRZ |
![]() |
AXH010A0G-SRZ |
![]() |
AXH010A0Y9-SR |
![]() |
AXH010A0P9-SR |
![]() |
AXH010A0G9-SR |
![]() |
AXH010A0D93-SR |
![]() |
AXH010A0D93-SRZ |
![]() |
AXH010A0G-SR |
![]() |
AXH010A0G9-SRZ |
![]() |
AXH010A0G93-SRZ |
![]() |
AXH010A0F9-SRZ |
![]() |
AXH010A0M9-SRZ |
![]() |
AXH010A0F93-SR |
![]() |
AXH010A0F93-SRZ |
![]() |
AXH010A0M93-SRZ |
![]() |
AXH010A0F9-SR |
![]() |
AXH010A0F-SR |
![]() |
AXH010A0P-SRZ |
![]() |
AXH010A0D9-SRZ |
![]() |
AXH010A0M-SRZ |
![]() |
AXH010A0PZ |
![]() |
AXH010A0M9-SR |
![]() |
AXH010A0F-SRZ |
PDF Datasheet Preview |
---|
Data Sheet March 28, 2008 Austin LynxTM SMT Non-Isolated dc-dc Power Modules Vdc - Vdc Input, Vdc - Vdc Output, 10 A n Workstations,Servers and Desktop computers n Distributed Power Architectures n Telecommunications Equipment n LANs/WANs n Data processing Equipment n Latest generation IC’s DSP, FPGA, ASIC and Micropro- cessor-powered applications. n Compatible with RoHS EU Directive 200295/EC n Compatible in Pb- free or SnPb reflow environment n Delivers up to 10A output current n High efficiency 95% at 3.3V full load n Small size and low profile: 33 mm x mm x mm in x in x in n Light Weight oz 6.5 g n Cost-efficient open frame design n High reliability MTBF > 10M hours at 25 °C n Constant switching frequency 300 KHz typical n Output overcurrent protection with auto-restart n Overtemperature protection n Surface Mount Package,Tape and Reel n Adjustable output voltage -5% to +10% for 0.9V output n Remote On/Off n Wide Operating temperature range:-40 °C to +85 °C n UL* 60950 Recognized, CSA† C22.2 No. 60950-00 Certified, and 0805 IEC60950, 3rd edition Licensed Options n Remote Sense Austin Lynx power modules are non-isolated dc-dc converters that can deliver 10 A of output current with full load efficiency of 95% at V output. These open frame modules in surface-mount-package enable designers to develop cost-and space efficient solutions. Standard features include remote ON/OFF, output voltage adjustment, overcurrent and overtemperature protection. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. § This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. The CE mark is placed on selected products. ** ISO is a registered trademark of the Internation Organization of Standards Document Name FDS02-034EPS ver.1.6 PDF Name Austin Lynx SMT Data Sheet March 28, 2008 Austin LynxTM SMT Non-Isolated dc-dc Power Modules Vdc - Vdc Input, Vdc - Vdc Output, 10 A Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliabiltiy. Parameter Input Voltage:Continuous Device Unit Operating Ambient Temperature See Thermal Considerations section Storage Temperature Tstg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Unit Operating Input Voltage AXH010A0S0R9-SR AXH010A0S1R0-SR AXH010A0P-SR AXH010A0M-SR AXH010A0Y-SR AXH010A0D-SR AXH010A0G-SR AXH010A0F-SR Maximum Input Current VI = 0 V to 75 V IO = IO, max II, max Input Reflected Ripple Current, peak-peak 5 Hz to 20 MHz, 1µH source impedance TA = 25 °C;CIN =200µF Input Ripple Rejection 120 Hz Remote Sense Austin Lynx SMT power modules offer an option for a Remote-Sense function. When the Device Code description includes a suffix “3”, pin 3 is added to the module and the Remote-Sense is an active feature. See the Ordering Infor- Lineage Power Overtemperature Protection To provide additional protection in a fault condition, the unit is equipped with a nonlatched thermal shutdown circuit. The shutdown circuit engages when Q1 or Q2 shown in Figure 24 exceeds approximately 110 °C. The unit attempts to restart when Q1 or Q2 cool down and cycles on and off while the fault condition exists. Recovery from shutdown is accomplished when the cause of the overtemperature condition is removed. Overcurrent Protection To provide protection in a fault condition, the unit is equipped with internal overcurrent protection. The unit operates normally once the fault condition is removed. The power module will supply up to 170% of rated current for less than seconds before it enters thermal shutdown. Data Sheet March 28, 2008 Austin LynxTM SMT Non-Isolated dc-dc Power Modules Vdc - Vdc Input, Vdc - Vdc Output, 10 A Thermal Considerations The power module operates in a variety of thermal environments however, sufficient cooling should be provided to help ensure reliable operation of the unit. Heat is removed by conduction, convection, and radiation to the surrounding environment. The thermal data presented is based on measurements taken in a wind tunnel. The test setup shown in Figure 25 was used to collect data for Figures 26 and Note that the airflow is parallel to the short axis of the module as shown in Figure The derating data applies to airflow along either direction of the module’s short axis. Wind Tunnel PWBs Pin 6 Power Module Air flow Probe Location for measuring airflow and ambient temperature AIRFLOW Figure Temperature Measurement Location. The temperature at either location should not exceed 110 °C. The output power of the module should not exceed the rated power for the module VO, set x IO, max . Convection Requirements for Cooling To predict the approximate cooling needed for the module, refer to the Power Derating curves in Figures 26 and These derating curves are approximations of the ambient temperatures and airflows required to keep the power module temperature below its maximum rating. Once the module is assembled in the actual system, the module’s temperature should be checked as shown in Figure 24 to ensure it does not exceed 110 °C. Proper cooling can be verified by measuring the power module’s temperature at Q1-pin 6 and Q2-pin 6 as shown in Figure Figure Thermal Test Setup. Output Current IO A m/s 400 ft./min. m/s 200 ft./min. m/s 100 ft./min. NATURAL CONVECTION Ambient Temperature TA Figure Typical Power Derating Vs Output Current for VIN. OUTPUT CURRENT, IO A m/s 400 ft./min. m/s 200 ft./min. m/s 100 ft./min. NATURAL CONVECTION AMBIENT TEMPERATURE, TA Lineage Power Figure Typical Power Derating Vs Output Current for 5.0VIN. Data Sheet March 28, 2008 Austin LynxTM SMT Non-Isolated dc-dc Power Modules Vdc - Vdc Input, Vdc - Vdc Output, 10 A Layout Considerations Copper paths must not be routed beneath the power module. Surface Mount Information Pick and Place Area Although the module weight is minimized by using openframe construction, the modules have a relatively large mass compared to conventional surface-mount components. To optimize the pick-and-place process, automated vacuum equipment variables such as nozzle size, tip style, vacuum pressure, and placement speed should be considered. Austin Lynx SMT modules have a flat surface which serves as a pick-and-place location for automated vacuum equipment. The module’s pick-and-place location is identified by the target symbol on the top label as shown in Figure allowed to fuse the plating on the connection to ensure a reliable solder joint. There are several types of SMT reflow technologies currently used in the industry. These surface mount power modules can be reliably soldered using natural forced convection, IR radiant infrared , or a combination of convection/IR. For reliable soldering the solder reflow profile should be established by accurately measuring the modules CP connector temperatures. Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table Device Codes without TRIM Input Voltage Output Voltage Output Current 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A Efficiency 83 85 86 88 90 91 92 95 88 90 92 95 Connector Type Device Code Comcodes AXH010A0R0S9-SR AXH010A0R1S0-SR AXH010A0P-SR AXH010A0M-SR AXH010A0Y-SR AXH010A0D-SR AXH010A0G-SR AXH010A0F-SR AXH010A0M-SRZ AXH010A0Y-SRZ AXH010A0G-SRZ AXH010A0F-SRZ 108967597 108967605 108967571 108967563 108967589 108967530 108967555 108967548 CC109104915 CC109104956 CC109104907 CC109106886 Table Device Codes with TRIM Input Voltage Output Voltage Output Current 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A Efficiency 83 85 86 88 90 91 92 95 86 88 90 92 95 Connector Type Device Code Comcodes AXH010A0R0S99-SR AXH010A0R1S09-SR AXH010A0P9-SR AXH010A0M9-SR AXH010A0Y9-SR AXH010A0D9-SR AXH010A0G9-SR AXH010A0F9-SR AXH010A0P9-SRZ AXH010A0M9-SRZ AXH010A0Y9-SRZ AXH010A0G9-SRZ AXH010A0F9-SRZ 108966177 108966110 108966144 108966136 108966169 108966102 108966128 108966094 CC109105896 CC109101417 CC109101425 CC109102935 CC109106878 Lineage Power Data Sheet March 28, 2008 Austin LynxTM SMT Non-Isolated dc-dc Power Modules Vdc - Vdc Input, Vdc - Vdc Output, 10 A Ordering Information continued Optional remote sense feature can be ordered using suffix 3 shown in Table For example, a AXH010A0Y-SR with remote sense is AXH010A0Y3-SR Table Device Options Remote Sense RoHS Compliant Option Suffix 3 -Z A sia-Pacific Head qu art ers T el +65 6 41 6 4283 World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D rive, Mesquite, T X 75149, U SA +1-800-526-7819 Outs id e U .S.A +1- 97 2-2 84 -2626 ag ep ower.co m e-m ail tech sup lin ea gep ower.co m Eu ro pe, M id dle-East an d Afric a He ad qu arters T el +49 8 9 6089 286 Ind ia Head qu arters T el +91 8 0 28411633 Lineage Power reserves the right to make changes to the produc t s or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct s or information. 2008 Lineage Power Corpor ation, Mesquite, Texas All International Rights Res er ved. Document Name FDS02-034EPS ver.1.6 PDF Name Austin Lynx SMT |
More datasheets: MAX4090EXT+ | MAX4090AAUT+ | IXFN150N10 | BTS824R | MSWSE-040-10 | MK23-35-B-2 | AXH010A0Y93-SR | AXH010A0P93-SR | AXH010A0P9-SRZ | AXH010A0Y93-SRZ |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived AXH010A0Y9-SRZ Datasheet file may be downloaded here without warranties.