Fluke 1750
Part | Datasheet |
---|---|
![]() |
FLUKE-1750/B (pdf) |
PDF Datasheet Preview |
---|
Fluke 1750 Three-Phase Power Recorder Technical Data Never miss capturing a the exclusive threshold-free measurement system, it’s automatic. Capture every measurement, every event, on every cycle, all the time with the Fluke 1750 Power Recorder. Outstanding accuracy and resolution provide complete visibility into your installation or distribution system. • Power quality that meets the standard: All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, har- monics, etc. • Quick and reliable PDA wire- less “front panel interface” provides the ability to verify setup without a laptop along with a window into what the instrument is recording, even in awkward test locations. • Threshold-free setup Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to worry about missed information due to incorrect set-up. • Captures everything Cross-channel and current triggering capture every measurement, on every channel, every time. • Intuitive PC software Easily analyze data and generate reports. Automated EN50160 reporting and compliance. • Plug and play Set up in minutes with self- identifying current probes and single-lead voltage connections. • No need to reconnect wires Swap channels internally with the wireless PDA or PC when connections are not correct. • Measure every parameter voltage and current on three phases, neutral, and ground. • 5 MHz, 8000 Vpk waveform capture Get a detailed picture of even the shortest events. • Quickly retrieve data With included SD memory card or via the 100BaseT high-speed Ethernet connection. Long-term analysis Uncover or intermittent issues monitor critical equipment, capturing power quality events to correlate with equipment malfunction Power quality surveys Quantify power quality throughout a facility, documenting results with professional reports Quality of service compliance Validate incoming power quality at the service entrance Equipment Installation/Commissioning Benchmark power system prior to install to insure quality of service Easy to use The recorder automatically detects, scales, and powers current probes without needing batteries. Requiring only single-lead voltage connections enables safe and quick setups. Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range no more uncertainty that data is being recorded. The Fluke 1750 has an exclusive capture algorithm which makes certain all events are captured without the tedious setups and blind spots associated with threshold driven equipment. The PDA wirelessly interfaces with the recorder, allowing quick setup and with waveform displays, meter screens, and phasor diagrams. The built-in wireless technology allows you to control multiple instruments from a distance easily, without the need for a laptop computer laptops can also be used when desired . Ordering information Fluke 1750 Three-Phase Power Recorder Includes: • 1750 acquisition unit • PDA wireless “front panel interface” and charger power plug adapters • 4 - 400 A current probes 3140R • 5 test leads and clips • SD memory card • Fluke Power View and Fluke Power Analyze software • Power cord with international plug set • Ethernet cable • Color localization set • Printed Getting Started manual • Product CD with software and users manual PDF • Soft carrying case Fluke 1750/B Three-Phase Basic Power Recorder Includes items above with the exception of the 4 - 400 A current probes 3140R Fluke offers a full suite of power quality test tools to locate, predict, prevent and troubleshoot power problems. • Handheld troubleshooters for in- stant analysis • Ready-to-use power loggers • Comprehensive power quality re- corders • Power calibrators and standards backed by Fluke metrology expertise The Fluke power quality set of products offers the highest level of performance and maintains the Fluke promise of rugged and reliable test tools. 8 Fluke Corporation Fluke 1750 Three-Phase Power Recorder Fluke. Keeping your world up and Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call In the U.S.A. 800 443-5853 or Fax 425 446-5116 In Europe/M-East/Africa +31 0 40 2675 200 or Fax +31 0 40 2675 222 In Canada 800 -36-FLUKE or Fax 905 890-6866 From other countries +1 425 446-5500 or Fax +1 425 446-5116 Web access: 2006-2009 Fluke Corporation. is a registered trademark of Microsoft Corporation. subject to change without notice. Printed in U.S.A. 10/2009 2428201F D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation. Pub-ID 11578-eng |
More datasheets: FH10A-24S-1SHB | FH10A-16S-1SHB | FH10A-14S-1SHB | FH10A-12S-1SHB | FH10A-8S-1SHB | FH10A-26S-1SHB | PTFB191501EV1XWSA1 | PTFB191501EV1R250XTMA1 | PTFB191501FV1XWSA1 | PTFB191501FV1R250XTMA1 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived FLUKE-1750/B Datasheet file may be downloaded here without warranties.