TECHNICAL DATA

Fluke 1732 and 1734 Three-Phase Electrical Energy Loggers

Energy logging is now within your where you’re wasting energy, optimize your facility’s energy use and reduce your bill

The new Fluke 1732 and 1734 Three-Phase Electrical Energy loggers introduce a new simplicity to discovering sources of electrical energy waste. Discover when and where energy in your facility is being consumed from the service entrance to individual circuits. Access and share data remotely with your team via the Fluke app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins.

Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.

KEY MEASUREMENTS Automatically capture and log voltage, current, power, power factor, energy and associated values

FLUKE COMPATIBLE* View data locally on the instrument, via Fluke app and desktop software or through your facilities’ WiFi infrastructure.

CONVENIENT INSTRUMENT POWERING Power instrument directly from the measured circuit

HIGHEST SAFETY RATING IN THE INDUSTRY 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
• Measure all three phases With included 3 flexible current
probes.
• Comprehensive logging More than 20 separate logging
• Optimized user interface Quick, guided, graphical setup
ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty.
• Bright, color touch screen Perform convenient in-the-field
analysis and data checks with full graphical display.
• Optimized user interface Capture the right data every
time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
• Complete “in-the-field” setup through the front panel
or Fluke Connect No need to return to the workshop for download and setup or to take a computer to the electrical panel.
• Fully integrated logging Connect other Fluke Connect devices
to the Fluke 1734 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module.*
• Energy Analyze Plus application software Download and
analyze every detail of energy consumption with our automated reporting.
*Not all models are available in all countries. Check with your local Fluke representative.

Fluke-Direct.com

Load studies Discover how much energy individual pieces of equipment are consuming when they are operating at minimum and maximum capacity. Check capacity of circuits prior to adding additional loads various standards exist for this process in the US the NEC 22087 is the recommended standard . Load studies can also identify situations where you may be exceeding the allowable load on the circuit or when an agreed peak demand applies from the utility. For convenience, some load studies simply measure current which makes installation of the measuring equipment quick and easy. It is often recommended that load surveys be performed for 30 days so that all typical load conditions are encountered during the test.

Energy assessments quantify energy consumption before, and after improvements, to justify energy saving devices

Energy surveys Users often ask where measurements should be taken for an energy survey. The answer is multiple points within the facility. Start at the main service feeders compare the power and energy measured here with the readings from the utility meter to ensure you’re receiving the correct charges. Then move downstream to the larger loads these should be easy to identify by the current rating of the electrical panels downstream of the service entrances. Measuring at many points will allow a full picture of energy usage across the facility to be developed. The next question users typically have is how long an energy survey should last. This of course depends on the facility, but it is recommended that you measure for a period that matches a typical facility activity period. If the facility operates over a five day work week with down time on the weekend, a seven day survey will most likely capture typical conditions. If the facility operates

Conduct multiple studies with one instrument download while studies are in progress via USB stick or Fluke Connect mobile app.

Suitable for NEC 220 load studies
at a constant level for 24 hours a day, 365 days a year, a single day could be reasonably representative as long as you avoid a period where there may be planned maintenance.

To capture a full picture of the facilities energy usage it is not necessarily required to have measurements made simultaneously at every consumption point in the facility. To get a comprehensive picture, spot measurements can be made and then compared on a sliding time timescale. For example, you could compare the service entrance results from a typical Tuesday between 6:00 am and 12:00 pm with those of a larger load in the facility. Typically there will be some correlation between these profiles.

Logging related analog measurements When conducting energy studies, it is useful to log related analog measurements such as temperature, voltage, current or pressure. These variables provide a better overall picture of operating conditions and allow you to correlate asset performance data with energy consumption. Correlating these variables provides more of the data you need to make cost saving performance adjustments. With the Fluke 1734, up to two Fluke Connect wireless modules can be used to capture these measurements, and the values will be automatically logged along with power and energy readings.

Use up to two Fluke Connect wireless modules with the Fluke 1734 to capture analog measurements

F l u ke - D i re c t 2 Fluke Corporation Fluke 1732 and 1734 Three-Phase Electrical Energy Loggers
.com

Applications continued

Power and energy logging When a piece of equipment is operated it instantaneously consumes a specific amount of power in watts W or kilowatts kW . This power is accumulated over the operating time and expressed as energy consumed in kilowatt hours kWh . Energy is what your electric utility charges for there will be a standard charge from the utility per kilowatt hour. Utilities may have other additional charges, such as peak demand, which is the maximum power demand over a defined period of time, often 15 or 30 minutes.

There may also be power factor charges, which are based on the effects of the inductive or capacitive loads in the facility. Optimizing peak demand and power factor often results in lower monthly electricity bills. The 1733 and Fluke 1734 Three Phase Electrical Energy loggers have the capability to measure and characterize these effects enabling you to analyze the results and save money.

Easy to use
Ordering information**

FLUKE-1732/B Energy Logger, Basic version excludes current probes FLUKE-1732/EUS Energy Logger, EU and US version includes current probes FLUKE-1732/INTL Energy Logger, International version includes current probes FLUKE-1734/B Energy Logger, with Fluke excludes current probes FLUKE-1734/EUS Energy Logger, EU/US with Fluke Connect includes current probes FLUKE-1734/INTL Energy Logger, International with Fluke Connect includes current probes FLUKE-1734/WINTL Energy Logger, International wireless version includes current probes

Fluke 1732 includes Instrument, power supply, voltage test leads, alligator clips 4x , 12 in 1,500A flexible current probe 3x , soft case, Energy Analyze Plus software, line cords, color coding set and documentation on USB flash drive

Fluke 1734 includes Instrument, power supply, voltage test leads, alligator clips 4x , 12 in 1,500A flexible current probe 3x , soft case, Energy Analyze Plus software, magnetic hanging strap, magnetic voltage probes 4x , WiFi/BLE adapter**, line cords, color coding set and documentation on USB flash drive
**Not all models are available in all countries. Check with your local Fluke representative.

Preventive maintenance simplified. Rework eliminated.

Save time and improve the reliability of your maintenance data by wirelessly syncing measurements using the Fluke system.
• Eliminate data-entry errors by saving measurements directly from the
tool and associating them with the work order, report or asset record.
• Maximize uptime and make confident maintenance decisions with data
you can trust and trace.
• Access baseline, historical and current measurements by asset.
• Move away from clipboards, notebooks and multiple spreadsheets with
a wireless one-step measurement transfer.
• Share your measurement data using ShareLiveTM video calls and emails.
• The Fluke 1732 and 1734 Three-Phase Electrical Energy Loggers are
part of a growing system of connected test tools and equipment maintenance software. Visit the website to learn more about the Fluke Connect system.

All trademarks are the property of their respective owners. WiFi or cellular service required to share data. Smartphone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Phone support details can be viewed at fluke.com/phones. Smart phone wireless service and data plan not included with purchase. Fluke Connect is not available in all countries.

F l u ke - D i re c t 10 Fluke Corporation Fluke 1732 and 1734 Three-Phase Electrical Energy Loggers
.com
More datasheets: FYMD8820 | SPD30N03S2L20GBTMA1 | KSA1150YTA | KSA1150OTA | CA3102R20-29SF80 | DDMM50PF225 | SGP5N60RUFDTU | BM03B-ACHSS-GAN-TF(LF)(SN) | BM02B-ACHSS-GAN-TF(LF)(SN) | DAMAM-15P-F0


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived FLUKE-1732/B Datasheet file may be downloaded here without warranties.

Datasheet ID: FLUKE-1732/B 635332