CR-P2

CR-P2 Datasheet


Cell Type CR-P2

Part Datasheet
CR-P2 CR-P2 CR-P2 (pdf)
PDF Datasheet Preview
Cell Type CR-P2

Typical Characteristics

Specifications

Nominal Capacity*1
1400mAh

Nominal Voltage

Standard Discharge Current
10mA

Max. Discharge Current

Continuous*2 Pulse*3
1500mA 3500mA

Temperature Range

Weight
34.8mm

Dimensions
19.5mm
35.8mm
*1 Nominal capacity is determined to an end voltage of 4.0V when the battery is allowed to discharge at a standard current level at 23oC.
*2 Current value is determined to be the level at which 50% of the nominal capacity is obtained with an end voltage of 4.0V at 23 oC.
*3 Current value for obtaining 2.0V cell voltage when pulse is applied for 15seconds at 50% discharge depth at 23 oC.

Pulse Discharge Characteristics of CR-P2

Pulse 1.2A*3s on/7s off In itia l

Cell Voltage V
2 3 oC
-2 0oC

Pulse Discharge Characteristics of CR-P2

Pulse 0.9A*3s on/27s off Initia l
2 3o C

Cell Voltage V
-2 0o C
800 1000 1200 1400 1600 1800

Number of Cycles

Discharge Characteristics of CR-P2

Load 400ohm T e mp. 2 3oC In itia l 6
200 400 600 800 1000 1200 1400 1600 1800 2000

Number of Cycles

Cell Voltage V
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140

Duration hour

Just measured data, not guaranteed.