B88069X0400S102

B88069X0400S102 Datasheet


FS04X-1JM Ordering code B88069X0400S102

Part Datasheet
B88069X0400S102 B88069X0400S102 B88069X0400S102 (pdf)
PDF Datasheet Preview
Switching Spark Gap
FS04X-1JM Ordering code B88069X0400S102

Nominal breakdown voltage VN

Initial values Static breakdown voltage VS 1 2 First ignition value VS, FTE after 24 hours in darkness Following ignition values selection limits Following ignition values VS, FIV Breakdown voltage VB measuring time 200 ms 4 First ignition value VB, FTE Following ignition values VB, FIV

Electrical life time 3 Breakdown voltage VB First ignition value VB, FTE initial after 24 hours in darkness First ignition value VB, FTE after 24 hours in darkness Following ignition values VB, FIV

Switching operations at - 40 °C at - 40 °C at +25 °C at +25 °C at +125 °C

Ignition time tI 60 ms 5 Ignition time tI 200 ms Ignition time tI 60 ms Ignition time tI 200 ms Ignition time tI 60 ms

Test circuit parameters Open circuit voltage V0 Loading resistance R Discharge capacitance C Inductance L Discharge peak current IP

General technical data Insulation resistance at 100 V Early ignition values below 340 V Breakdown time Maximum switching frequency Maximum loading current Weight

Marking, blue
1 At delivery AQL 0,65 level II, DIN ISO 2859 2 Page 2, Fig. 1 and 2 3 Page 2, Fig. 3 and 4 Page 2, Fig. 3 and 4, 100 % outgoing inspection 5 After storage in darkness for 30 days
360 420
350 430
340 460
460 500 340 460
60 000 100 000 100 000 200 000 200 000

Ignitions
~ 500
> 100
400 WWY O
400 - Nominal voltage

WW - Calendar week of production
- Year of production
- Non radioactive

AB E / AB PM

Issue 05,

Switching Spark Gap
FS04X-1JM Ordering code B88069X0400S102

Fig. 1 QC- test circuit 100% outgoing inspection

I = const
0,22µF

DUT VS

DUT device under test ICU ignition control unit sensitivity 10 30 µA Discharge current 10 20 mA

Fig. 3 QC- test circuit sampling inspection at 25 °C

Fig. 2 Explanation of measurands

VS, FTE VS, FIV
t - VN
dVS/dt ~ dVN/dt

Fig. 4 Explanation of measurands

VB, FTE Range of VB, FIV

VB Early ignition

VB, FTE
tI 1s

Not to scale Dimensions in mm Non controlled document

EPCOS AG Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI German Electrical and Electronic Manufacturers' Association , unless otherwise agreed.

AB E / AB PM

Issue 05,
More datasheets: H-843 | 305-044-520-202 | EKSFDCAWD | EYSFDCAWD | 17-10019 | 17-10012 | 17-10009 | 2N5953 | 2N5953_J35Z | 3254J/2H3P


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B88069X0400S102 Datasheet file may be downloaded here without warranties.

Datasheet ID: B88069X0400S102 511749