B65840D2000X

B65840D2000X Datasheet


Series/Type B65839, B65840

Part Datasheet
B65840D2000X B65840D2000X B65840D2000X (pdf)
PDF Datasheet Preview
Ferrites and accessories

EP7 Core and accessories

Series/Type B65839, B65840

The following products presented in this data sheet are being withdrawn.
Ordering Code

Substitute Product

Date of Withdrawal Deadline Last Orders

Last Shipments

B65840D2000X000
2013-05-29
2013-08-31
2013-11-30

For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at

EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

EPCOS AG is a TDK Group Company.
• To IEC 61596
• For transformers featuring high inductance and low overall height
• For power applications
• Delivery mode sets

Magnetic characteristics per set l/A = le = mm Ae = mm2 Amin = mm2 Ve = 162 mm3

Approx. weight g/set

EP 7 Core

Gapped

Material AL value
approx.
63 ±3%
100 ±3%
160 ±5%
200 ±6%
250 ±7%
63 ±3%
100 ±3%
160 ±5%
200 ±6%
250 ±7%
63 ±3%
100 ±3%
160 ±5%

B65839
∗ gapped one-sided

FEP0004-T
Ordering code

B65839A0063A038 B65839A0100A038 B65839A0160J038 B65839A0200C038 B65839A0250E038 B65839A0063A057 B65839A0100A057 B65839A0160J057 B65839A0200C057 B65839A0250E057 B65839A0063A045 B65839A0100A045 B65839A0160J045

Please read Cautions and warnings and

Important notes at the end of this document.09/06

Core
200 ±6%
250 ±7%
63 ±3%
100 ±3%
160 ±5%
200 ±6%
250 ±7%

Ungapped

Material AL value

B65839 B65839A0200C045 B65839A0250E045 B65839A0063A087 B65839A0100A087 B65839A0160J087 B65839A0200C087 B65839A0250E087
Ordering code

W/set
1500 1820

B65839A0000R057
1500 1820

B65839A0000R045
2000 2430

B65839A0000R030
3000 3640

B65839A0000R065
5200 6310

B65839A0000Y038
5800 7040

B65839A0000Y066
1100 1330 < 200 mT, 100 kHz, 100 B65839A0000R087

Please read Cautions and warnings and

Important notes at the end of this document.09/06

Accessories Coil former

Material GFR thermosetting plastic UL 94 V-0, insulation class to IEC 60085 F max. operating temperature 155 °C , color code green Vyncolit/X611 [E167521 M ], VYNCOLIT NV

Solderability to IEC 60068-2-20, test Ta, method 1 aging 3 235 °C, 2 s Resistance to soldering heat to IEC 60068-2-20, test Tb, method 1B 350 °C, s Winding see Data Book 2007, chapter “Processing notes, Squared pins.

B65840

Cap yoke

With ground terminal, made of stainless spring steel tinned , mm thick

Coil former
Ordering code

Sections 1

AN mm2
lN mm

AR value

Terminals

B65840B1006D001

B65840B1006D002

Cap yoke

B65840D2000X000

Please read Cautions and warnings and

Important notes at the end of this document.09/06

Coil former
pin 1

Marking

Cap yoke

View A
9,6 min. 0,4
8,2 min. 6,6 min.

Hole arrangement View in mounting direction

Accessories

Ground

Preliminary data

SMD coil former with gullwing terminals

FEP0005-Z-E
1_0 ,1
3,8 5,6

FEP0006-U

B65840

Material GFR liquid crystal polymer UL 94 V-0 , color code black Sumika Super E4008 [E54705 M ], SUMITOMO CHEMICAL CO LTD

Solderability to IEC 60068-2-58, test Td, method 6 Group 3 245 °C, 3 s

Resistance to soldering heat to IEC 60068-2-58, test Td, method 6 Group 3 255 °C, 10 s permissible soldering temperature for wire-wrap connection on coil former 400 °C, 1s

Sections AN

AR value
Terminals Ordering code

B65840N1106T001

Please read Cautions and warnings and

Important notes at the end of this document.09/06

Recommended PCB layout

FEK0475-T-E

Please read Cautions and warnings and

Important notes at the end of this document.09/06

Ferrites and accessories Cautions and warnings Mechanical stress and mounting Ferrite cores have to meet mechanical requirements during assembling and for a growing number of applications. Since ferrites are ceramic materials one has to be aware of the special behavior under mechanical load. As valid for any ceramic material, ferrite cores are brittle and sensitive to any shock, fast changing or tensile load. Especially high cooling rates under ultrasonic cleaning and high static or cyclic loads can cause cracks or failure of the ferrite cores. For detailed information see Data Book 2007, chapter “General Definitions,

Effects of core combination on AL value Stresses in the core affect not only the mechanical but also the magnetic properties. It is apparent that the initial permeability is dependent on the stress state of the core. The higher the stresses are in the core, the lower is the value for the initial permeability. Thus the embedding medium should have the greatest possible elasticity. For detailed information see Data Book 2007, chapter “General Definitions,

Heating up Ferrites can run hot during operation at higher flux densities and higher frequencies.

NiZn-materials The magnetic properties of NiZn-materials can change irreversible in high magnetic fields.

Processing notes The start of the winding process should be soft. Else the flanges may be destroid. To strong winding forces may blast the flanges or squeeze the tube that the cores can no more
be mount. To long soldering time at high temperature >300 °C may effect coplanarity or pin
arrangement. Not following the processing notes for soldering of the J-leg terminals may cause solderability
problems at the transformer because of pollution with Sn oxyd of the tin bath or burned insulation of the wire. For detailed information see Data Book 2007, chapter “Processing notes, The dimensions of the hole arrangement have fixed values and should be understood as a recommendation for drilling the printed circuit board. For dimensioning the pins, the group of holes can only be seen under certain conditions, as they fit into the given hole arrangement. To avoid problems when mounting the transformer, the manufacturing tolerances for positioning the customers’ drilling process must be considered by increasing the hole diameter.
09/06 7

Important notes

The following applies to all products named in this publication Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health e.g. in accident prevention or life-saving systems , it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer e.g. installation of protective circuitry or redundancy that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions e.g. because they are classed as “hazardous” . Useful information on this will be found in our Material Data Sheets on the Internet Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association ZVEI .
09/06 8

The trade names EPCOS, EPCOS-JONES, Baoke, Alu-X, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIFERRIT, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at
09/06 9
More datasheets: STK17TA8-RF25 | STK17TA8-RF45 | STK17TA8-RF25ITR | STK17TA8-RF25TR | STK17TA8-RF45ITR | STK17TA8-RF45TR | 2942 | FDPF8N50NZ | FDPF8N50NZT | ZX3CD2S1M832TA


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B65840D2000X Datasheet file may be downloaded here without warranties.

Datasheet ID: B65840D2000X 511602