B57276K March 2013
Part | Datasheet |
---|---|
![]() |
B57276K0123A028 (pdf) |
PDF Datasheet Preview |
---|
NTC thermistors for temperature measurement Probe assemblies Series/Type Date: B57276K March 2013 EPCOS AG Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Temperature measurement Probe assemblies B57276K K276 Applications Washing machines Dish washers Tumble-dryers Water boilers Features Suitable for use in corrosive environments Compact stainless steel case RAST or RAST 5 connector Cost-effective ready-to-use sensor UL approval E69802 VDE approval DIN EN 60539-1 2002 Options Alternative resistance ratings, rated temperatures and resistance tolerances available on request. RAST 5 plug terminals or RAST connector with bar available on request. Type Z276, Z277 and Z278 with different geometry and faster response time available on request. Delivery mode Bulk Dimensional drawings Dimensions A max. RAST connector 1204 3243 RAST 5 connector 1082 3243 Plug terminal mm Approx. weight 9 g Approx. weight 9 g Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 10 Temperature measurement Probe assemblies B57276K K276 General technical data Climatic category Max. power Resistance tolerance Dissipation factor Thermal time constant Heat capacity Insulation resistance Test voltage IEC 60068-1 at 25 °C in water in water V = 100 V DC t = 1 s P25 Cth Rins Vtest 10/100/56 500 ±2 approx. 20 approx. 20 approx. 500 > 1000 3750 mW % mW/K s mJ/K V AC Electrical specification and ordering codes RAST connector 1204 3243 RAST 5 connector 1082 3243 4829 11981 4829 11981 No. of R/T B25/100 characteristic K Ordering code 2003 2901 3980 ±1% B57276K0482A007 3760 B57276K0123A028 2003 2901 3980 B57276K0482A009 3760 B57276K0123A024 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 10 Temperature measurement Probe assemblies B57276K K276 Reliability data Test Storage in dry heat Storage in damp heat, steady state Rapid temperature cycling Endurance Long-term stability empirical value Robustness of terminations Standard Test conditions IEC 60068-2-2 IEC 60068-2-78 IEC 60068-2-14 DIN 46 249 Storage at upper category temperature T 100 °C t 1000 h Temperature of air 40 °C Relative humidity of air 93% Duration 56 days Lower test temperature °C Upper test temperature 100 °C Number of cycles 10 Pmax 500 mW t 1000 h Temperature 100 °C t 10000 h Pull-out force both connectors together F = 50 N typical < 2% < 2% < 3% Remarks No visible damage No visible damage No visible damage No visible damage No visible damage No visible damage Note Contact of NTC thermistors with any liquids and solvents shall be prevented. It must be ensured that no water enters the NTC thermistors e.g. through plug terminals . Avoid dewing and condensation unless thermistor is specified for these conditions. Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 10 Temperature measurement Probe assemblies R/T characteristics R/T No. T °C To be replaced by a number in ordering Platzhalter für Zahl im Bestellnummern- codes, type designations etc. code oder für die Typenbezeichnung. To be replaced by a letter. Platzhalter für einen Buchstaben. All dimensions are given in mm. Alle Maße sind in mm angegeben. The commas used in numerical values Verwendete Kommas in Zahlenwerten denote decimal points. bezeichnen Dezimalpunkte. Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 10 Important notes The following applies to all products named in this publication: Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health e.g. in accident prevention or lifesaving systems , it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer e.g. installation of protective circuitry or redundancy that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions e.g. because they are classed as hazardous . Useful information on this will be found in our Material Data Sheets on the Internet Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association ZVEI . The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at Page 10 of 10 |
More datasheets: AT-42000-GP4 | ATA5824-PLQW | ATA5823-PLQW | ATA5823-PLQW 80 | ATA5824-PLQW 80 | 15188-4RS | 15188-4 | 15188-3RS | 15188-4R | 15188-3 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived B57276K0123A028 Datasheet file may be downloaded here without warranties.