PDF Datasheet Preview
5mm x 20mm Fuses

S506 Series, Time Delay, Glass Tube

Description
• Time delay, low breaking capacity
• Optional axial leads available
• 5mm x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2 32mA-10A

RoHS 2002/95/EC

S506 ELECTRICAL CHARACTERISTICS
10 In
max min max min max min max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec 10 ms 300 ms
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
8A-15A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms

Agency Information
• UL Recognized Card 32mA-15A Guide JDYX2,

File E19180
• CSA Component Acceptance File 53787
• cURus Recognition Guide JDYX8, File E19180
• SEMKO Approval, 32mA-10A
• VDE Approval, 32mA-10A
• BSI Approval, 32mA-10A
• IMQ Approval, 32mA-10A
• MITI Approval, 32mA-6.3A
• CCC Approval, 32mA-6.3A
Ordering
• Specify packaging, product, and option code
• For -R option, drop mA or A from product code
i.e. S506-2-R

Dimensions

Drawing Not to Scale
• Ratings above 6.3A have a 0.8mm diameter lead
• With TR2 packaging code, lead wire length is 19.05mm

Product Code

S506-32mA S506-40mA S506-50mA S506-63mA S506-80mA S506-100mA S506-125mA S506-160mA S506-200mA S506-250mA S506-315mA S506-400mA S506-500mA S506-630mA S506-800mA S506-1A S506-1.25A S506-1.6A S506-2A S506-2.5A S506-3.15A S506-4A S506-5A S506-6.3A S506-8A S506-10A S506-12.5A S506-15A

Voltage Rating

AC 250V

SPECIFICATIONS

Interrupting Rating

Typical DC
at Rated Voltage 50Hz Cold Resistance
ohms *
100A
125A
125A
* DC Cold Resistance Measured at <10% of rated current † Minimum Pre-Arching I2t Measured at 10 In and rated voltage Typical Voltage Drop Voltage drop was measured at 20°C ambient temperature at rated current

Minimum Pre-Arching I2t

A2Sec AC† 15 25 51 88 150 214 192 420 812 1029

Typical Voltage Drop
1050 920 800 760 580 490 390 320 340 270 250 210 140 150 75 80 70 68 66 60 55 54 45 73
5mm x 20mm Fuses

S506 Series, Time Delay, Glass Tube

TIME CURRENT CURVE

Packaging Code BK BK1 TR2

Option Code V -R

PACKAGING CODE

Description 100 pieces of fuses packed into a cardboard carton 1,000 pieces of fuses packed into a poly bag 1,500 pieces of fuses packed into tape on a reel 19.05mm lead wire length

OPTION CODE

Description Axial leads - copper tinned wire with nickel plated brass overcaps RoHS compliant version

Visit us on the web at:

OC-2574 3/07

Cooper Electronic Technologies 2007

North America

Cooper Electronic Technologies Cooper Bussmann
1225 Broken Sound Parkway NW P.O. Box 14460

Suite F

St. Louis, MO 63178-4460
More datasheets: C9114-00 | C9116-00 | C9120-00 | C9122-00 | C9124-00 | C9128-00 | C8128-04 | C8108-04 | B39871B3573U310W3 | BK/S506-1.6A


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BK/S506-8A Datasheet file may be downloaded here without warranties.

Datasheet ID: BK/S506-8A 506387