7.2SDLSJ amp 7.2SDLSJ amp
Part | Datasheet |
---|---|
![]() |
7.2WKMSJ250 (pdf) |
Related Parts | Information |
---|---|
![]() |
3.6ADOSJ25 |
![]() |
27.6SFMSJ50 |
![]() |
27.6SDMSJ20 |
![]() |
27.6SDMSJ6.3 |
![]() |
27.6SDMSJ10 |
![]() |
27.6SFMSJ40 |
![]() |
17.5SFLSJ50 |
![]() |
27.6SFMSJ31.5 |
![]() |
25SFMSJ50 |
![]() |
12SFLSJ50 |
![]() |
3.6ADOSJ31.5 |
![]() |
25SFMSJ40 |
![]() |
3.6ADOSJ40 |
![]() |
3.6ADOSJ6.3 |
![]() |
17.5SDLSJ10 |
![]() |
7.2WKMSJ355 |
![]() |
27.6SDMSJ25 |
![]() |
7.2WKMSJ315 |
PDF Datasheet Preview |
---|
HIGH VOLTAGE DIN DISTRIBUTION kV 36 kV FUSES DIN Dimension Fuses To Spec. DIN This product group covers current limiting fuses with dimensions to DIN and performance in compliance with IEC Advantages of Edison High Voltage Current Limiting Fuse The low power dissipation of Edison fuses ensures low temperature rise of switchgear in which they are incorporated. The elements use the ‘M’ metallurgical effect, similar to that used in low voltage fuses. This ensures that, with melting on long time overloads, excessive temperatures are not reached and damage to switchgear components, such as epoxy encapsulating enclosures, is thus prevented. Fuses of Continental European manufacture which in general do not employ this feature are not only hotter running by comparison but also usually need to employ a higher current rating of fuse for the same service thus an Edison 40A fuse is equivalent in terms of thermal performance to many Continental European types of 63A rating. Edison fuses exhibit considerable limitation of current and I2t under short circuit conditions. The stress on circuit components is thereby minimized and the reduction of energy release at the fault reduces fire risks. Switching arc voltages are appreciably less than permitted values and fall with lower values of recovery voltage. The use of, for example, 12 kV fuse on kV systems is therefore permissible. Striker Characteristics The spring operated striker pin has a travel and energy output in compliance with the requirements of DIN 43625 and IEC Travel is approx. 26mm Energy Output is approx. joule Force/Travel Output Characteristics 60 FORCE N TRAVEL mm Current Ratings These are in accordance with the R10 and, in some cases, the R20 series of preferred numbers. Table of Ratings and Dimensions Catalog No. Rating Amps 3.6ADOSJ amp 3.6WDOSJ amp 10, 16, 20, 25, 40 50, 63, 80, 100, 125 3.6WFOSJ amp 3.6WFOSJ amp 3.6ADLSJ amp 3.6WDLSJ amp 10, 16, 20, 25, 40 50, 63, 80, 100, 125 3.6WFLSJ amp 3.6WKLSJ amp 160, 200 250, 315, 400 7.2SDLSJ amp 7.2SDLSJ amp 10, 16, 20, 25, 40, 50, 63 7.2SFLSJ amp 7.2SFLSJ amp 80, 100 125, 160 7.2WKMSJ amp 7.2WKMSJ amp 200, 225 250, 315, 355 12SDLSJ amp 12SDLSJ amp 10, 16, 20, 25, 40, 50, 63 12SFLSJ amp 12SKLSJ amp 12SKLSJ amp 50, 63, 80, 100 125 160, 200 17.5SDLSJ amp 17.5SDLSJ amp 17.5SFLSJ amp 17.5SFLSJ amp 17.5SDMSJ amp |
More datasheets: 25SFMSJ50 | 12SFLSJ50 | 3.6ADOSJ31.5 | 25SFMSJ40 | 3.6ADOSJ40 | 3.6ADOSJ6.3 | 17.5SDLSJ10 | 7.2WKMSJ355 | 27.6SDMSJ25 | 7.2WKMSJ315 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 7.2WKMSJ250 Datasheet file may be downloaded here without warranties.