3.6ADOSJ6.3

3.6ADOSJ6.3 Datasheet


3.6ADOSJ amp 3.6WDOSJ amp

Part Datasheet
3.6ADOSJ6.3 3.6ADOSJ6.3 3.6ADOSJ6.3 (pdf)
Related Parts Information
3.6ADOSJ25 3.6ADOSJ25 3.6ADOSJ25
27.6SFMSJ50 27.6SFMSJ50 27.6SFMSJ50
27.6SDMSJ20 27.6SDMSJ20 27.6SDMSJ20
27.6SDMSJ6.3 27.6SDMSJ6.3 27.6SDMSJ6.3
27.6SDMSJ10 27.6SDMSJ10 27.6SDMSJ10
27.6SFMSJ40 27.6SFMSJ40 27.6SFMSJ40
17.5SFLSJ50 17.5SFLSJ50 17.5SFLSJ50
27.6SFMSJ31.5 27.6SFMSJ31.5 27.6SFMSJ31.5
25SFMSJ50 25SFMSJ50 25SFMSJ50
12SFLSJ50 12SFLSJ50 12SFLSJ50
3.6ADOSJ31.5 3.6ADOSJ31.5 3.6ADOSJ31.5
25SFMSJ40 25SFMSJ40 25SFMSJ40
3.6ADOSJ40 3.6ADOSJ40 3.6ADOSJ40
17.5SDLSJ10 17.5SDLSJ10 17.5SDLSJ10
7.2WKMSJ355 7.2WKMSJ355 7.2WKMSJ355
27.6SDMSJ25 27.6SDMSJ25 27.6SDMSJ25
7.2WKMSJ315 7.2WKMSJ315 7.2WKMSJ315
7.2WKMSJ250 7.2WKMSJ250 7.2WKMSJ250
PDF Datasheet Preview
HIGH VOLTAGE DIN DISTRIBUTION kV 36 kV FUSES

DIN Dimension Fuses To Spec. DIN This product group covers current limiting fuses with dimensions to DIN and performance in compliance with IEC

Advantages of Edison High Voltage Current Limiting Fuse The low power dissipation of Edison fuses ensures low temperature rise of switchgear in which they are incorporated.

The elements use the ‘M’ metallurgical effect, similar to that used in low voltage fuses. This ensures that, with melting on long time overloads, excessive temperatures are not reached and damage to switchgear components, such as epoxy encapsulating enclosures, is thus prevented. Fuses of Continental European manufacture which in general do not employ this feature are not only hotter running by comparison but also usually need to employ a higher current rating of fuse for the same service thus an Edison 40A fuse is equivalent in terms of thermal performance to many Continental European types of 63A rating.

Edison fuses exhibit considerable limitation of current and I2t under short circuit conditions. The stress on circuit components is thereby minimized and the reduction of energy release at the fault reduces fire risks.

Switching arc voltages are appreciably less than permitted values and fall with lower values of recovery voltage. The use of, for example, 12 kV fuse on kV systems is therefore permissible.

Striker Characteristics The spring operated striker pin has a travel and energy output in compliance with the requirements of DIN 43625 and IEC

Travel is approx. 26mm Energy Output is approx. joule

Force/Travel Output Characteristics 60

FORCE N

TRAVEL mm

Current Ratings These are in accordance with the R10 and, in some cases, the R20 series of preferred numbers.

Table of Ratings and Dimensions

Catalog No.

Rating Amps
3.6ADOSJ amp 3.6WDOSJ amp
10, 16, 20, 25, 40 50, 63, 80, 100, 125
3.6WFOSJ amp
3.6WFOSJ amp
3.6ADLSJ amp 3.6WDLSJ amp
10, 16, 20, 25, 40 50, 63, 80, 100, 125
3.6WFLSJ amp 3.6WKLSJ amp
160, 200 250, 315, 400
7.2SDLSJ amp 7.2SDLSJ amp
10, 16, 20, 25, 40, 50, 63
7.2SFLSJ amp
7.2SFLSJ amp
80, 100 125, 160
7.2WKMSJ amp 7.2WKMSJ amp
200, 225 250, 315, 355
12SDLSJ amp 12SDLSJ amp
10, 16, 20, 25, 40, 50, 63
12SFLSJ amp
12SKLSJ amp
12SKLSJ amp
50, 63, 80, 100 125 160, 200
17.5SDLSJ amp
17.5SDLSJ amp
17.5SFLSJ amp
17.5SFLSJ amp
17.5SDMSJ amp
More datasheets: 27.6SDMSJ6.3 | 27.6SDMSJ10 | 27.6SFMSJ40 | 17.5SFLSJ50 | 27.6SFMSJ31.5 | 25SFMSJ50 | 12SFLSJ50 | 3.6ADOSJ31.5 | 25SFMSJ40 | 3.6ADOSJ40


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 3.6ADOSJ6.3 Datasheet file may be downloaded here without warranties.

Datasheet ID: 3.6ADOSJ6.3 506332