TD-110

TD-110 Datasheet


Figure 1 - TD-025 35

Part Datasheet
TD-110 TD-110 TD-110 (pdf)
Related Parts Information
TD-125 TD-125 TD-125
TD-085 TD-085 TD-085
TD-095 TD-095 TD-095
TD-105 TD-105 TD-105
TD-080 TD-080 TD-080
TD-120 TD-120 TD-120
TD-060 TD-060 TD-060
TD-115 TD-115 TD-115
TD-075 TD-075 TD-075
TD-065 TD-065 TD-065
TD-055 TD-055 TD-055
TD-050 TD-050 TD-050
TD-045 TD-045 TD-045
TD-040 TD-040 TD-040
TD-035 TD-035 TD-035
TD-030 TD-030 TD-030
TD-025 TD-025 TD-025
TD-020 TD-020 TD-020
TD-015 TD-015 TD-015
TD-100 TD-100 TD-100
TD-070 TD-070 TD-070
TD-090 TD-090 TD-090
PDF Datasheet Preview
TD Over Current Detector

Hall effect type current sensor with a single digital output factory programmed to go low when a given current threshold is exceeded. The TD Series is able to operate within a temperature range of -40o C to 125o C and has a fast response time of 1!s typical . The miniature package size allows the TD series to be mounted on printed circuit boards and is integrated with an open collector digital output which is ideal for interfacing to control circuitry.

Welding equipment, servo drives, treadmills, automotive power conversion, power supplies, home audio, MRI equipment

Series TD
Ordering Information

Type No

Over Current Detector

Trip Point
15 Amp
20 Amp
25 Amp
30 Amp
35 Amp
40 Amp
45 Amp
50 Amp
55 Amp
60 Amp
65 Amp
70 Amp
75 Amp
80 Amp
85 Amp
90 Amp
95 Amp
100 Amp
105 Amp
110 Amp
115 Amp
120 Amp
125 Amp
TD - 025 = ordering example

Technical Data

Absolute Maximum Ratings Supply Voltage Externally Applied to Output

Output ON current sink Operating Temp Range Sensed Current RMS voltage for AC isolation test, 50/60 Hz, 1 minute
to +25 VDC +25 VDC max Output high, current below Itrip VDC min Output high or low 50 mA -40o C to +125o C +/- 500 Amp peak kVac

Absolute maximum ratings are the extreme limits that the detector will withstand without damage. Electrical operation and characteristics are not guaranteed as the maximum limits are approached. Proper application of the detector must ensure that the detector operates within the operating characteristics below.

Operating Characteristics

Supply Voltage Supply Current Operating Temperature Output Trip Time Output ON Voltage Output ON Current

Symbol Vs Is Ttrip Vos Ios

Typ.

Note 1 Detector sensitive to unidirectional current as defined in mechanical dimension drawing

Max 125 20

Notes VDC mA oC !S, di/dt=Itrip/!S VDC sinking 20 mA
01/2009
1551 Bishop Ct. Mt. Prospect , IL 60056 P 847 827-7600 F 847 827-7655
!D 8ver Current Detector
!rip Currents 0Amps 2 34o C6
!rip Current
:a 28 56 84
!rip Current 80 85 90 95 100 105 110 115 120 125
:in 88 110
!rip Current vs. !emperature
:a 112 140

Trip Point Amps

Figure 1 - TD-025 35
0 40 20 0 20 40 60 80 100 120 Temperature C

Maximum Typical Minimum

Trip Point Amps

Figure 2 - TD-030 40
0 40 20 0 20 40 60 80 100 120 Temperature C

Maximum Typical Minimum

Trip Point Amps

Figure 3 - TD-035 50
0 40 20 0 20 40 60 80 100 120 Temperature C

Maximum Typical Minimum

Trip Point Amps

Figure 4 - TD-040 60
0 40 20 0 20 40 60 80 100 120 Temperature C

Maximum Typical Minimum
01/200%
1551 Bishop Ct.1 Mt. Prospect , IL 60056 P =47 =27-7600 F =47 =27-7655
More datasheets: AD7937BRZ | FIT0236 | ACW105 | 200 | BCM5345MKPB | 500-303T-W05 | TD-125 | TD-085 | TD-095 | TD-105


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived TD-110 Datasheet file may be downloaded here without warranties.

Datasheet ID: TD-110 510428