Thermal Overcurrent Circuit Breaker 3130
Part | Datasheet |
---|---|
![]() |
3130-F110-P7T1-W29AG2-15A (pdf) |
Related Parts | Information |
---|---|
![]() |
3130-F120-P7T1-W12QY7-7A |
![]() |
3130-F120-P7T1-W12QY7-5A |
![]() |
3130-F120-P7T1-W12QY7-3A |
![]() |
3130-F120-P7T1-W12QY7-15A |
![]() |
3130-F120-P7T1-W12QY7-10A |
![]() |
3130-F110-P7T1-W29AG3-10A |
![]() |
3130-F110-P7T1-W29AG2-5A |
![]() |
3130-F110-P7T1-W29AG2-4A |
![]() |
3130-F110-P7T1-W29AG2-10A |
![]() |
3130-F110-P7T1-W29A-2A |
![]() |
3130-F110-H7T1-W29AG3-2.5A |
![]() |
3130-F110-P7T1-W29AG2-3A |
![]() |
3130-F110-P7T1-W29AG2-2A |
![]() |
3130-F110-P7T1-W12QY6-5A |
![]() |
3130-F110-H7T1-W29AG3-10A |
![]() |
3130-F1B0-N7Q1-W19QG7-20A |
![]() |
3130-F311-P7T1-W12QY1-2.5A |
![]() |
3130-F311-P7T1-W12QY2-2.5A |
![]() |
3130-F311-P7T1-W12QY3-2.5A |
![]() |
3130-F120-P7T1-W29AB7-10A |
![]() |
3130-F120-P7T1-W29AB7-2.5A |
![]() |
3130-F130-P7T1-W12QY7-8A |
PDF Datasheet Preview |
---|
Thermal Overcurrent Circuit Breaker 3130 Single, two and three pole rocker switch/thermal trip free circuit breakers S-type TO CBE to EN 60934 of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double pole version, protection on one pole only. Illumination is optional and there is a choice of rocker colours. Approved to CBE standard EN 60934 IEC Motors, transformers, solenoids, household and office machines, electrical tools, mobile homes, boating, construction vehicles, medical equipment to EN 1 pole 3130 3 pole Standard current ratings and typical internal resistance values Technical data Current rating A 1 2 3 Internal resistance per pole 94 24 12 Current rating A 4 5 6 7 8 10 12 14 15 16 18 20 Internal resistance per pole < < < < < < < Illumination voltage/power consumption operating voltage 6V 12 V 24 V 48 V 115 V 230 V 415 V * single pole version only power consumption filament/neon B LED G, R, Y 60 mA 20 mA 20 mA 20 mA < 1 mA* < 1 mA* < 1 mA not available Approvals Authority VDE EN 60934 UL, CSA Voltage rating AC 240/415 V DC 50 V DC 28 V AC 250 V, DC 50 V 3 AC 250 V Current rating single pole multi pole single pole multi pole single pole A 1 and 2 pole A 3 pole All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. For further details please see chapter Technical Information Voltage rating AC 240 V 3 AC 415 V DC 50 V UL AC 250 V 3 AC 250 V DC 50 V Current ratings A 1 pole A 2 and 3 pole Typical life AC 240 V DC 50 V: DC 28 V: AC 240 V A DC 50 V A 3 AC 415 V A Ambient temperature 1 pole 30,000 operations at 1 x IN, inductive 30,000 operations at 1 x IN, inductive 30,000 operations at 1 x IN, resistive 30,000 operations at 1 x IN, inductive 2 pole 50,000 operations at 1 x IN, inductive 50,000 operations at 1 x IN, inductive 3 pole 30,000 operations at 1 x IN, inductive °C °F Insulation co-ordination IEC 60664 and 60664 A rated impulse pollution withstand voltage degree reinforced insulation in operating area Dielectric strength IEC 60664 and 60664A test voltage operating area AC 3,000 V current path/current path AC 1,500 V Insulation resistance >100 DC 500 V Interrupting capacity Icn A 14 + 16 A 10 x IN 150 A 250 A 150 A 130 A 1 pole 2 pole 3 pole 3 pole Interrupting capacity UL 1077 1 + 2 pole AC 250V/3500A AC 250V/3500A 3 pole 3AC 250V/5000A 1 + 2 pole DC 50V/2000A DC 50V/2000A Degree of protection IEC 60529/DIN 40050 operating area IP40 terminal area IP00 Vibration 5 g 57-500 Hz , mm 10-57 Hz to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 1 pole 25 g 11 ms 2 + 3 pole 20 g 11 ms to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity Ordering information - 1 pole Ordering information - multipole Type No. Type No. 3130 rocker switch/circuit breaker 3130 rocker switch/circuit breaker multipole Mounting Mounting F snap in frame F snap in frame Frame Frame 1 standard 1 standard 3 special single pole version Number of poles 1 single pole, thermally protected Number of poles 2 pole, thermally protected 3 pole, thermally protected A 1 pole, unprotected** 5 2 pole, thermally protected on one pole only Frame mounting 6 3 pole, thermally protected on two poles only 0 panel thickness mm in only 3130-F1..-... B 2 pole, unprotected** 1 panel thickness mm in only 3130-F3.1-... C 3 pole, unprotected** Terminal design Frame mounting P7 blade terminals DIN 46244-C-Ms-S QC 2x.110 0 panel thickness mm in only 3130-F1..-... H7 for terminals terminal screws M Terminal design for terminals blade terminals QC 2x.110 P7 blade terminals DIN 46244-C-Ms-S QC 2x.110 N7 blade terminals QC 2x.110 , with shunt terminal H7 for terminals terminal screws M Characteristic curve for terminals blade terminals T1 thermal, IN Q1 switch, only with terminal design -N7 QC 2x.110 N7 blade terminals DIN 46244-C-Ms-S QC 2x.110 , Switch style with shunt terminal 3130 - F 1 0 - P7 T1 - W 12 Q Y 7 - 5 A ordering example 8 320 - 450 V B Current ratings * N/A for non-illuminated version ** unprotected poles have to ordered with terminal design N7 *** without series resistor and diode, to be selected by customer. 3130 - F 1 3 0 - P7 T1 - W 12 Q B 7 - 5 A ordering example Recommendation: 4-7 V Rv * N/A for non-illuminated version 10-14 V Rv ** unprotected poles have to ordered with terminal design N7 20-28 V RV diode 1N4007 05/06 290405 Thermal Overcurrent Circuit Breaker 3130 Dimensions I.3 I.2 LINE I.I terminal for illumination conductor size mm2 AWG26 , length 180 mm in. switch only 20 34 LINE I.I blade terminals DIN 46244-C-Ms-S QC 2x.110 P7 or N7 Side view I.3 I.2 LINE I.I 20 34 LINE I.I unit blade terminals DIN 46244-C-Ms-S QC 2x.110 P7 or N7 Side view .118R3 flat head screw M3.5x5 -MS ISO 1580 H7 tightening torque max. Nm Panel cut-out panel thickness mm in. <<R.002.50 illuminated dot -.29AG.- min. min I.3 I.2 LINE I.I 20 34 LINE I.I unit blade terminals DIN 46244-C-Ms-S QC 2x.110 P7 or N7 Side view Ordering information - IP 66 Dimensions 3130-F212-... Type No. 3130 rocker switch/circuit breaker Mounting F snap in frame Frame 2 splash water protected Number of poles 1 single pole, thermally protected A 1 pole, unprotected ** Frame mounting GERMANY LINE I.I terminal for illumination flying lead conductor size mm2, length 180 mm in. 2 panel thickness mm Terminal design P7 blade terminals DIN 46244-C-Ms-S QC 2x.110 H7 for terminals terminal screws M for terminals 2 x blade terminals N7 blade terminals DIN 46244-C-Ms-S QC 2x.110 , with shunt terminal or for switch only 20 34 blade terminals DIN 46244-C-Ms-S QC 2x P7 or N7 Side view Characteristic curve T1 thermal, IN LINE I.I Q1 switch, only with terminal design -N7 Switch style S 00 without actuator rocker X 222 420 must be ordered separately. flat head screw M3.5x5 -MS ISO 1580 H7 tightening torque max. Nm Available symbols see following pages. S rocker P momentary switch Switch colour designation not S00 opaque translucent 01 black 12 white 02 white 14 red 04 red 19 green 3130 F 2 1 2 - P7 T1 - S 12 Q Y 7 - 5 A ordering example LINE I.I * N/A for non-illuminated version ** unprotected poles have to ordered with terminal design N7 *** without series resistor and diode, to be selected by customer. Recommendation 4-7 V Rv 0,43 10-14 V Rv 1,1 20-28 V RV 2,7 diode 1N4007 mounting area This metric design millimeter dimensions take precedence mm inch 05/06 290405 Thermal Overcurrent Circuit Breaker 3130 Internal connection diagrams 1 pole line I.I lamp load 1 pole switch line I.I 1 pole momentary switch line I.I lamp load lamp load Typical time/current characteristics 10000 1000 +60 °C +140 °F +23 °C °F -30 °C -22 °F Trip time in seconds 10000 4 6 8 10 times rated current 1000 +60 °C +140 °F +23 °C °F -30 °C -22 °F All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 05/06 290405 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 3130-F110-P7T1-W29AG2-15A Datasheet file may be downloaded here without warranties.