3120-F321-H7T1-W19LB3-10A

3120-F321-H7T1-W19LB3-10A Datasheet


3120-...-..T1-..

Part Datasheet
3120-F321-H7T1-W19LB3-10A 3120-F321-H7T1-W19LB3-10A 3120-F321-H7T1-W19LB3-10A (pdf)
Related Parts Information
3120-F30F-G7Q1-SGRXB3-X3120-U0000M-20A 3120-F30F-G7Q1-SGRXB3-X3120-U0000M-20A 3120-F30F-G7Q1-SGRXB3-X3120-U0000M-20A
3120-F30F-G7Q1-SGRXB3-X3120-U0001M-20A 3120-F30F-G7Q1-SGRXB3-X3120-U0001M-20A 3120-F30F-G7Q1-SGRXB3-X3120-U0001M-20A
3120-F321-P7T1-W15DB3-5A 3120-F321-P7T1-W15DB3-5A 3120-F321-P7T1-W15DB3-5A
3120-F323-P7T1-W19DG0-8A 3120-F323-P7T1-W19DG0-8A 3120-F323-P7T1-W19DG0-8A
3120-F621-P7T1-W02D-15A 3120-F621-P7T1-W02D-15A 3120-F621-P7T1-W02D-15A
3120-F324-H7T1-W01D-X3120-U0203-16A 3120-F324-H7T1-W01D-X3120-U0203-16A 3120-F324-H7T1-W01D-X3120-U0203-16A
3120-F321-P7T1-W14FB3-2.5A 3120-F321-P7T1-W14FB3-2.5A 3120-F321-P7T1-W14FB3-2.5A
3120-F323-P7T1-W12LB3-16A 3120-F323-P7T1-W12LB3-16A 3120-F323-P7T1-W12LB3-16A
3120-F32U-P7T1-W12FY0-15A 3120-F32U-P7T1-W12FY0-15A 3120-F32U-P7T1-W12FY0-15A
3120-F313-P7T1-W12FB3-20A 3120-F313-P7T1-W12FB3-20A 3120-F313-P7T1-W12FB3-20A
3120-F323-P7T1-W19LB1-16A 3120-F323-P7T1-W19LB1-16A 3120-F323-P7T1-W19LB1-16A
3120-F321-P7T1-W12DB4-10A 3120-F321-P7T1-W12DB4-10A 3120-F321-P7T1-W12DB4-10A
PDF Datasheet Preview
The information furnished is believed to be accurate and reliable. However, E-T-A assumes no responsibility for its use. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.

Technical data

Max.voltage rating Rated insulation voltage Current rating range

Current ratings

Reference ambient temperature

Effect of the ambient temperature on the tripping characteristics

Creepage resistance Method of operation Mode of tripping

Typical electrical operational values

Voltage
drop

Insulation coordination IEC 664 and 664A

Dielectric strength IEC 664 and 664A operating area reinforced insulation, sheet 23 mounting area sheet 23 pole / pole 2-pole Insulation resistance Minimum load main circuit

Overcurrent Circuit Breaker thermal trip
3120-...-..T1-..
one and two pole

Data Sheet
sheet 1 of 37

Replacing data sheet dated Oct. 1997
to EN 60 934

AC 240V / DC 50 V, AC 415V AC 415 V 20A 1 and 2 pole
-30°C +60°C T60

Temperature °C Factor Temperature °C Factor PTI 400 S-type TO / positively trip free
-30 -20 -10 -5 +10 +23 +30 +40 +50 +60

Rated impulse withstand voltage / Pollution degree

EN 60 934
4kV / 3
2.5KV /2
max.
4000 V
2000 V
2000 V
test voltage, AC

EN 60 934
3000 V
1500 V
1500 V
> 100 DC 500 V DC 10 V / 100 mA

The copying, distribution and utilization of this document as well as the communication of its contents to others without expressed authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or ornamental design registration. Protection mark according to DIN
075.367g /

Index ÄM Sheet

Date Name Index ÄM
Ordering number code

Overcurrent Circuit Breaker thermal trip
3120-...-..T1-..
one and two pole

Data Sheet
sheet 29 of 37
3 120-F 321 - N7
2 345 6

T1 -W12A B 4 - 10A
8 9 10 11 12

Type number
3120 Thermal or thermal-magnetic circuit breaker, single or double pole with ON / OFF switch only option

Mounting method F Snap-in frame or screw mounting

Configuration
1 for rocker
for 2 push buttons
2 and water splash
cover
for rocker or push buttons
4 for rocker
5 for rocker
6 for rocker
7 for rocker
panel cut-out x mm
x mm x mm x mm x mm x mm
panel thickness screw mounting x
- mm - mm - mm - mm 4.0mm
snap-in housing

Number of poles
0 2 pole, unprotected, switch only 1 pole, thermally protected 2 pole, thermally protected 5 2 pole, thermally protected on one only 6 1 pole, unprotected, switch only

The copying, distribution and utilization of this document as well as the communication of its contents to others without expressed authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or ornamental design registration. Protection mark according to DIN
075.367g /

Index

Date Name Index
17 866

K.Go

Date Name
3120 series datasheet.doc

The information furnished is believed to be accurate and reliable. However, E-T-A assumes no responsibility for its use. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.

Style, accessory

Overcurrent Circuit Breaker thermal trip
Note Boldface references are in conformance with the ordering informations shown in the E-T-A Catalogue

Index
17 866
3120 series datasheet.doc

Date Name Index

K.Go
thermal trip
3120-...-..T1-..
one and two pole

Date Name

Data Sheet
sheet 37 of 37
075.367g /
More datasheets: 1142 | 3120-F30F-G7Q1-SGRXB3-X3120-U0000M-20A | 3120-F30F-G7Q1-SGRXB3-X3120-U0001M-20A | 3120-F321-P7T1-W15DB3-5A | 3120-F323-P7T1-W19DG0-8A | 3120-F621-P7T1-W02D-15A | 3120-F324-H7T1-W01D-X3120-U0203-16A | 3120-F321-P7T1-W14FB3-2.5A | 3120-F323-P7T1-W12LB3-16A | 3120-F32U-P7T1-W12FY0-15A


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 3120-F321-H7T1-W19LB3-10A Datasheet file may be downloaded here without warranties.

Datasheet ID: 3120-F321-H7T1-W19LB3-10A 510414