1658 single pole thermal circuit breaker
Part | Datasheet |
---|---|
![]() |
1658-G41-00-S83-10A (pdf) |
Related Parts | Information |
---|---|
![]() |
1658-G41-00-P19-10A |
![]() |
1658-F01-00-P10-35A |
![]() |
1658-G41-02-P10-35A |
![]() |
1658-G41-02-P10-30A |
![]() |
1658-G41-04-S83-20A |
![]() |
1658-G41-04-S80-20A |
![]() |
1658-F01-00-S83-055800-15A |
![]() |
1658-G41-08-P13-20A |
![]() |
1658-G41-00-P10-30A |
![]() |
1658-F01-00-S83-055800-20A |
![]() |
1658-F01-00-P10-30A |
![]() |
1658-G21-08-S83-20A |
![]() |
1658-F01-00-S83-30A |
![]() |
1658-G41-02-S83-20A |
![]() |
1658-G41-04-S80-10A |
![]() |
1658-G41-02-S83-10A |
![]() |
1658-G41-00-P10-35A |
![]() |
1658-G41-02-S80-30A |
![]() |
1658-G41-09-P10-6A |
![]() |
1658-G21-06-P10-16A |
![]() |
1658-G21-06-P10-8A |
![]() |
1658-G41-02-P10-14A |
![]() |
1658-G41-07-P10-5A |
![]() |
1658-G41-02-S83-30A |
![]() |
1658-G41-06-P10-35A |
![]() |
1658-G41-04-S80-055843-25A |
![]() |
1658-G41-07-P10-30A |
![]() |
1658-F01-00-S83-055800-30A |
![]() |
1658-G41-00-S80-30A |
![]() |
1658-G41-00-S83-30A |
![]() |
1658-G41-04-P10-30A |
![]() |
1658-G21-03-S83-20A |
![]() |
1658-G41-02-P13-20A |
![]() |
1658-G41-09-S83-30A |
![]() |
1658-G41-08-P13-10A |
![]() |
1658-G41-07-P10-10A |
![]() |
1658-G41-02-P10-20A |
![]() |
1658-G41-02-P10-25A |
![]() |
1658-G41-06-P10-25A |
![]() |
1658-G21-06-P10-25A |
![]() |
1658-G41-06-P13-20A |
![]() |
1658-G41-06-P13-10A |
![]() |
1658-G41-10-P10-7A |
![]() |
1658-G41-04-P10-20A |
![]() |
1658-G41-02-P13-12A |
![]() |
1658-G41-04-P10-25A |
![]() |
1658-F01-00-S83-15A |
![]() |
1658-G41-00-S80-10A |
![]() |
1658-G41-00-P13-20A |
![]() |
1658-G21-02-S83-5A |
![]() |
1658-G41-09-P10-055800-10A |
![]() |
1658-F01-00-S83-20A |
![]() |
1658-G41-00-S83-25A |
![]() |
1658-G41-00-S80-25A |
![]() |
1658-G41-00-S80-20A |
![]() |
1658-G41-00-S83-20A |
![]() |
1658-G41-00-P13-12A |
![]() |
1658-G21-03-S80-15A |
![]() |
1658-G41-00-P13-10A |
![]() |
1658-G41-02-S83-15A |
![]() |
1658-G41-04-P10-15A |
![]() |
1658-G41-04-P10-5A |
![]() |
1658-G41-08-P10-20A |
![]() |
1658-G41-02-S80-15A |
![]() |
1658-G41-00-S80-15A |
![]() |
1658-G21-03-S83-15A |
![]() |
1658-G21-00-S83-055800-20A |
![]() |
1658-G41-00-P10-14A |
![]() |
1658-F01-00-P10-20A |
![]() |
1658-F01-00-P10-6A |
![]() |
1658-G41-00-P10-12A |
![]() |
1658-A21-00-P10-8A |
![]() |
1658-G41-00-P10-18A |
![]() |
1658-G41-00-P10-7A |
![]() |
1658-G41-00-P10-6A |
![]() |
1658-G41-00-P10-5A |
![]() |
1658-G41-00-P10-16A |
![]() |
1658-G41-00-P10-15A |
![]() |
1658-G41-00-P10-10A |
![]() |
1658-F01-00-P10-15A |
![]() |
1658-F01-00-P10-10A |
![]() |
1658-F01-00-P10-25A |
![]() |
1658-F01-00-P10-7A |
![]() |
1658-A21-00-P10-10A |
![]() |
1658-F01-00-P10-5A |
![]() |
1658-G41-01-P10-12A |
![]() |
1658-G41-01-P10-15A |
![]() |
1658-G41-01-P10-10A |
![]() |
1658-G41-01-P10-8A |
![]() |
1658-F01-00-P10-8A |
![]() |
1658-G41-06-P10-7A |
![]() |
1658-G41-00-P10-8A |
![]() |
1658-G41-06-P10-5A |
![]() |
1658-G41-02-P10-5A |
![]() |
1658-G41-08-P10-8A |
![]() |
1658-G41-08-P10-6A |
![]() |
1658-G41-06-P10-8A |
![]() |
1658-G41-01-P10-20A |
![]() |
1658-G41-00-P10-25A |
![]() |
1658-G41-00-P10-20A |
![]() |
1658-G41-09-P10-15A |
![]() |
1658-G41-02-P10-6A |
![]() |
1658-G41-02-P10-16A |
![]() |
1658-G41-02-P10-15A |
![]() |
1658-G41-02-P10-13A |
![]() |
1658-G41-02-P10-12A |
![]() |
1658-G41-02-P10-10A |
![]() |
1658-A21-00-P10-25A |
![]() |
1658-G41-02-P10-8A |
![]() |
1658-G41-02-P10-7A |
PDF Datasheet Preview |
---|
Thermal Overcurrent Circuit Breaker Very cost effective design to meet international requirements. No exposed metal parts which are, or could become, current-carrying except for terminals. R-type TO CBE to EN q Manual reset, cycling trip free mechanism q Extremely small and lightweight q UL, CSA, VDE and EN 60934 IEC 60934 approved Battery chargers, consumer products, power supplies, motors. Ordering information Type No. 1658 single pole thermal circuit breaker Threadneck design G21 manual reset type, 3/8"-27 threadneck G41 manual reset type, 7/16"-28 threadneck E00 manual reset without threadneck F01 snap-in type F02 press to reset, snap-in type A21 auto reset type, 3/8"-27 threadneck A41 auto reset type, 7/16"-28 threadneck A00 auto reset type, without threadneck A01 auto reset, snap-in type Hardware bulk mounted configuration hex nut knurled nut hex nut knurled nut 1 PAL 1 PAL 1 PAL 1 PAL 1 PAL 12 3/8-27 UNS 1 PAL 1 plastic 14 3/8-27 UNS 1 PAL 1 plastic 15 3/8-27 UNS 1 plastic 1 PAL 16 3/8-27 UNS 1 plastic 19 3/8-27 UNS 1 plastic 20 3/8-27 UNS 1 plastic Terminals P10 blade terminals A6.3-0.8 QC P13 blade terminals A6.3-0.8 QC 90° S80 straight screw terminals* S83 90° bent screw terminals* Current ratings 5 30 A 1658 - G21 - 02 - P10 - 5 A Ordering example * Screws and lock washers bulk shipped Standard current ratings and typical voltage drop values Current rating A 5 6 7 8 9 10 Voltage drop mV 150 140 Current rating A 12 15 16 20 25 30 Voltage drop mV 140 240 1658-F Technical data Voltage rating Current ratings Typical life Ambient temperature Insulation co-ordination IEC 60664 and 60664 A Dielectric strength IEC 60664 and 60664A operating area Insulation resistance Interrupting capacity Icn Interrupting capacity UL 1077/EN 60934 PC1 Degree of protection IEC 60529/DIN 40050 Vibration Shock Corrosion Humidity Mass AC 240 V DC 28 V 1,000 operations at 2 x IN °C °F , <8A max. +40 °C 104°F Rated impulse Pollution withstand voltage degree reinforced insulation in operating area Test voltage AC 3,000 V > 100 DC 500 V 200 A UN AC 240 V AC 120 V DC 28 V 2,000 A 2,000 A 2,000 A operating area IP 40 terminal area IP 00 8 g 57-500 Hz mm 10-57 Hz , to IEC 60068-2-6, Test Fc, 10 frequency cycles/axis 30 g 11 ms to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-3, test Ca approx. 16 g Approvals Authority VDE EN 60934 UL, CSA Voltage rating AC 240 V DC 28 V AC 250 V AC 240 V AC 120 V AC 125 V DC 28 V Current ratings 1658-G... 1658-G... All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. Issue D ¤ ¤ USA 847 827-7600 - - CANADA 905 764-9510 Thermal Overcurrent Circuit Breaker Dimensions Installation drawing operating area 3/8-27UNS-2A mounting hole 3/8-27UNS-2A Tightening Torque= Nm mounting hole mounting area Terminal design blade terminals DIN 46244-A6.3-0.8 QC terminal screw 6-32 UNC lock washer P10-S83 blade terminals DIN 46244-A6.3-0.8 QC angled 90° lock washer terminal screw 6-32 UNC blade terminals DIN 46244-A6.3-0.8 QC terminal screw 6-32 UNC lock washer 7/16-28UNS-2A double “D” See ordering information for mounting hardware This is a metric design and millimeter dimensions take precedence mincmh ¤ ¤ USA 847 827-7600 - - CANADA 905 764-9510 Issue D Thermal Overcurrent Circuit Breaker Internal connection diagram Typical time/current characteristics 10000 1000 +60 °C +140 °F +23 °C °F -20 °C -4 °F Trip time in seconds 4 6 8 10 times rated current The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 Technical information. Ambient temperature °F °C -4 +14 +32 +104 +122 +140 -20 -10 0 +23 +40 +50 +60 Multiplication factor Issue D ¤ ¤ USA 847 827-7600 - - CANADA 905 764-9510 Thermal Overcurrent Circuit Breaker Accessories Mounting nut 3/8", 27-thread Mounting nut 7/16", 28-thread Y306 671 01 Y303 200 01 Reset button seal for 3/8", 27-thread, short long X201 285 01 X200 799 01 3/8-27UNS-2B 7/16-28UNEF-2B Knurled nut 3/8", 27-thread nickel-plated brass Y300 190 03 Knurled nut 7/16", 28-thread nickel-plated brass Y302 294 03 3/8-27 UNS-2B 3/8-27 UNS-2B Reset button seal for 7/16", 28-thread, short long X222 119 01 X222 119 02 3/8-27UNS-2B |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 1658-G41-00-S83-10A Datasheet file may be downloaded here without warranties.