• 1 Introduction
• 2 Specification
• 3 Tutorial

Requirements Connection Diagram PC Control of POE Relay

Open the Software Select the network, and then select the network Control button, enter the network control interface Network Control of POE Relay Control the POE relay with RS485 BUS Reset and Restore Factory Settings Control

Introduction

The RLY-8 is a network relay controller with open source communication protocol. It integrates 8 channel relays and each relay could stand 277VAC-10A or 125VAC-12A power. Meanwhile most of the household appliances are under 250VAC, it means you could use it almost everywhere. The RLY-8 is using STM32 microcontroller. It supports 2 types of power supply Wall adapter or PoE Power over Ethernet power supply. You could reduce its connection cable via PoE power supply. In addition, you also could control it via RS485 port or TCP/IP protocol. And RS485 and JSON protocol has been opened on the website. This Ethernet relays are really great for IoT projects - with 8 relays, you have plenty of scope to try different things. Like a remote control light, a autoflowering greenhouse. With the open source protocol, you could add it in plenty of things you can do with this besides, just use your imagination!

Specification
• Operating Voltage DC:7-23V
• Relay number 8
• Data Communication Ethernet/RS485
• Network Configuration Supports DHCP and Static IP
• Power Consumption Max 3.5W
• Maximum Control 277VAC-10A/125VAC-12A
• Control Mode Ethernet/RS485
• Factory Settings IP port 2000
• Working Temperature -30~85
• Weight 530g
• Size 145mm * 90mm * 40mm 5.7in * 3.5in * 1.6in

Tutorial

Requirements
• Hardware POE relay x1 PC X1 USB to RS485 transfer line or ethernet cable POE Ethernet switch or ordinary Ethernet switch
• Software PC Software Windows Click to Download

Connection Diagram

RLY-8-PoE-RS485 supports 2 types of control mode Ethernet and RS485 In this section, we will introduce some typical connection:
• Ethernet

NOTE If you directly connect to the computer, you will need to set a static IP. Going by RLY factory settings, you can set your computer IP to 192.168.1.x is 0~254 except 10 , Subnetmask gateway
• RS485 BUS

PC Control of POE Relay Open the Software

Select the network, and then select the network Control button, enter the network control interface

NOTE It may take some time when the RLY-8 has just been powered on, please be patient waiting for the network list

Network Control of POE Relay

NOTE It is recommended to click the "Get Status" button to get the current state when you want to control the relay.

Control the POE relay with RS485 BUS

Reset and Restore Factory Settings

To reset the factory default settings, hold the reset button until the lights begin to flash.

Control