06AE2

06AE2 Datasheet


03AE1 06AE1 10AE1

Part Datasheet
06AE2 06AE2 06AE2 (pdf)
PDF Datasheet Preview
AESERIES POWER ENTRY MODULE EMI FILTERS

INTRODUCTIONS

Power module incorporates an IEC connector, a fuse holder with optional power on/off switch and voltage selector switch, plus an EMI filter all-in-one single, easy-to-install unit.

Fuse holder designed for one IEC 5x20mm fuse. Safety interlock prevents fuse removal with line plug inserted.

AE1/3/4/5 UL, CSA AE2 UL, CSA, VDE

MINIMUM INSERTION LOSS IN dB

COMMON MODE L-G IN 50 OHM SYSTEM

CURRENT

FREQUENCY-MHz

RATING
15 20
10 20 22
35 38
15 20
37 45

SPECIFICATIONS

Maximum leakage current each line-to-ground 115VAC 60Hz 0.25mA 250VAC 50Hz 0.45mA

Hipot rating one minute line-to-ground 2250VDC line-to-line 1450VDC

Operating frequency 50/60Hz Rated voltage 115/250VAC

TYPE & RATED CURRENT

DELTA PART NO.

IEC CONNECTOR FUSE HOLDER POWER SWITCH VOLTAGE SELECTOR SW ELECTRICAL SCHEMATIC
03AE1 06AE1 10AE1
03AE2 06AE2 10AE2
03AE3 06AE3
03AE4 06AE4
03AE5 06AE5

FIG. A

SP1 FIG. A

SP1 REAR2 FIG. A

REAR2 FIG. A

FRONT3 FIG. B

ELECTRICAL SCHEMATIC

FIG. A

AE1, AE4 without power SW L1 2.6mH 3A L1 0.5mH 6A L1 0.2mH 10A Cx 0.015uF Cy 3300pF

AE3, AE4 ONLY

L LF I N E

Cy Cx

FIG. B

L 110V O A 220V N' D
110V