QAS SERIES
Part | Datasheet |
---|---|
![]() |
QASP5M220A-L (pdf) |
Related Parts | Information |
---|---|
![]() |
QCS20S110AL |
![]() |
QASP100S110ADL |
![]() |
QASP100S24ADL |
![]() |
QASP60S220ADL |
![]() |
QAS2S110ADL |
![]() |
QASP10S110ADL |
![]() |
QASP5M220ADL |
![]() |
QASP10S24ADL |
![]() |
QAS1S110ADL |
![]() |
QCS20M110AL |
![]() |
QCS10S110AL |
![]() |
QCS20S220AL |
![]() |
QAS4M220ADL |
![]() |
QDS45S220A |
![]() |
QHS12H110A |
![]() |
QASP20M220A |
![]() |
QCS20S110A |
![]() |
QASP5M220AL |
![]() |
QAS120M220A |
![]() |
QDS45S110A |
PDF Datasheet Preview |
---|
TIMERS GENERAL DETAILS OF TYPE Q TIMERS Q series timers are compact, low cost, precision devices designed to the most demanding specifications. The small size, epoxy filled case is highly resistant against dust, vibrations, shock and humidity. Creep and strike distance according to VDE 0110 Group C 250V. Case protection IP66. Case material - Phenolic. 50.8mm 50.8mm TIMERS 250 DIA. MALE QUICK CONNECT TERMINALS QAS SERIES DELAY ON MAKE ELECTRONIC TIMER UL listed CSA recognized SPECIFICATIONS: Input Power 24 VAC/DC, 110 VAC/DC 220 VAC/DC ±15%, 50/60 Hz Output Rating max. A at 20°C min. 10 mA Voltage drop after timing VAC/DC Repetition accuracy at a constant ambient Temp rise derating 5 mA / °C Reset time SAS & SAS-D 25 ms after timing 50 ms during timing Leakage current during timing 5 mA max Peak surge current 20 A < 10 ms Peak surge voltage 1400 V, 10 µs Terminals 6.35mm quick connect Operating temperature -22°F to +140°F -30°C to +60°C Weight oz. 55g Peak Surge Current 100A 50A 20A 15A 10A Peak Surge Current vs Surge Current Duration 2A 1A 10ms 20ms 50ms 100ms 200ms 500ms 1s 2s 5s Surge Current Duration ORDERING INFORMATION 100 pcs. minimum P.S. Specify maximum time for “D” and “P” version. MOUNTING AS-D SERIES Input Power S1 Function A: Delay on Make Output Function A When input power is applied, timing t begins. At the end of the preselected time, the solid state SCR output turns on. The output turns off when the input power is removed, resetting the timer for the next cycle. WIRING DIAGRAM: QAS-D 470K +- +- LOAD LOAD INPUT INPUT Note Available with internal potentiometer in AS-P Series 100S TIME RANGE 220 AD INPUT POWER Q = Encapsulated AS = fixed time AS-D = remote potentiometer AS-P = internal potentiometer AS = Fixed sec - 120 min AS-D = sec - 60 min. 10:1 Ratio AS-P = sec - 10 sec 1-100 sec maintain 100:1 ratio 24AD = 24 VAC/DC 110AD = 110 VAC/DC 220AD = 220 VAC/DC 1 AMP 2/46a Products and specifications subject to change without notice. Order/Technical Support Tel 800 677-5311 / FAX 800 677-3865 / TIMERS QBS SERIES SINGLE SHOT TIMER QCS SERIES DELAY ON BREAK TIMER UL listed CSA recognized • CMOS Technology • Epoxy Encapsulated • x Compact Size • Quick Connect Terminals TIMERS Input Power S1 ORDERING INFORMATION 100 pcs. minimum DIMENSIONS See page 4-34 MOUNTING SERIES TIME RANGE 110A INPUT POWER Q = Encapsulated 2/46b CS = Fixed time BS = Fixed time CS-D = Remote potentiometer BS-D = Remote potentiometer CS-P = Internal potentiometer BS-P = Internal potentiometer CS/BS = Fixed time CS-D = sec. - 120 min BS-D = sec. - 120 min. maintain 10:1 ratio B or CSP = - 10 sec. or min 1 - 100 sec. or min. maintain 100:1 ratio 24A = 24 VAC 48A = 48 VAC 110A = 110 VAC 220A = 220 VAC Products and specifications subject to change without notice. Order/Technical Support Tel 800 677-5311 / FAX 800 677-3865 / 1 AMP TIMERS QDS SERIES REPEAT CYCLE QHS SERIES INTERVAL ELECTRONIC TIMER UL listed CSA recognized • Consistent Repeat Cycle • Multiple Voltage • Square Cases • Fixed and Variable Time Ranges TIMERS Function D: Function H: Function H The solid state output turns on when the input power Recycling Interval Timer S1 is applied. The output turns off at the end of time T . The timer Input is reset when the input power is removed. Power S1 Function D When input power S1 is applied, the sold state output Output turns on immediately for the time period specified. It then turns OFF T1 T2 t for that same time period and repeats continuously while power is applied. SPECIFICATIONS: Input 24 VAC, 48 VAC, 110 VAC 220 VAC, ±15%, 50/60 Hz Maximum power consumption 24 VAC VA 48 VAC VA 110 VAC VA 220 VAC VA ORDERING INFORMATION 100 pcs. minimum DIMENSIONS See page 4-34 MOUNTING SERIES 10 min TIME RANGE INPUT POWER Q = Encapsulated DS = Fixed time DS-D = Remote potentiometer HS = Fixed time HS-D = Remote potentiometer DS-P = Internal potentiometer HS-P = Internal potentiometer DS/HS = Fixed .1s - 120 min. DS-D/HS-D = sec - 120 min. maintaining 10:1 ratio DS-P/HS-P = sec or min 1-100 sec. or min. maintain 100:1 ratio 24A = 24 VAC 48A = 48 VAC 110A = 110 VAC 220A = 220 VAC 1 AMP 2/46c Products and specifications subject to change without notice. Order/Technical Support Tel 800 677-5311 / FAX 800 677-3865 / |
More datasheets: QCS10S110AL | QCS20S220AL | QAS4M220ADL | QDS45S220A | QHS12H110A | QASP20M220A | QCS20S110A | QASP5M220AL | QAS120M220A | QDS45S110A |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived QASP5M220A-L Datasheet file may be downloaded here without warranties.