QAS120M220A

QAS120M220A Datasheet


QAS SERIES

Part Datasheet
QAS120M220A QAS120M220A QAS120M220A (pdf)
Related Parts Information
QCS20S110AL QCS20S110AL QCS20S110AL
QASP100S110ADL QASP100S110ADL QASP100S110ADL
QASP100S24ADL QASP100S24ADL QASP100S24ADL
QASP60S220ADL QASP60S220ADL QASP60S220ADL
QAS2S110ADL QAS2S110ADL QAS2S110ADL
QASP10S110ADL QASP10S110ADL QASP10S110ADL
QASP5M220ADL QASP5M220ADL QASP5M220ADL
QASP10S24ADL QASP10S24ADL QASP10S24ADL
QAS1S110ADL QAS1S110ADL QAS1S110ADL
QCS20M110AL QCS20M110AL QCS20M110AL
QCS10S110AL QCS10S110AL QCS10S110AL
QCS20S220AL QCS20S220AL QCS20S220AL
QAS4M220ADL QAS4M220ADL QAS4M220ADL
QDS45S220A QDS45S220A QDS45S220A
QHS12H110A QHS12H110A QHS12H110A
QASP20M220A QASP20M220A QASP20M220A
QCS20S110A QCS20S110A QCS20S110A
QASP5M220AL QASP5M220AL QASP5M220AL
QDS45S110A QDS45S110A QDS45S110A
QASP5M220A-L QASP5M220A-L QASP5M220A-L
PDF Datasheet Preview
TIMERS

GENERAL DETAILS OF TYPE Q TIMERS

Q series timers are compact, low cost, precision devices designed to the most demanding specifications. The small size, epoxy filled case is highly resistant against dust, vibrations, shock and humidity. Creep and strike distance according to VDE 0110 Group C 250V. Case protection IP66. Case material - Phenolic.
50.8mm
50.8mm

TIMERS
250 DIA. MALE QUICK CONNECT TERMINALS

QAS SERIES

DELAY ON MAKE ELECTRONIC TIMER

UL listed CSA recognized

SPECIFICATIONS:

Input Power 24 VAC/DC, 110 VAC/DC 220 VAC/DC ±15%, 50/60 Hz

Output Rating max. A at 20°C min. 10 mA

Voltage drop after timing VAC/DC Repetition accuracy at a constant ambient Temp rise derating 5 mA / °C Reset time SAS & SAS-D 25 ms after timing
50 ms during timing Leakage current during timing 5 mA max Peak surge current 20 A < 10 ms Peak surge voltage 1400 V, 10 µs Terminals 6.35mm quick connect Operating temperature -22°F to +140°F -30°C to +60°C Weight oz. 55g

Peak Surge Current
100A 50A
20A 15A 10A

Peak Surge Current vs Surge Current Duration
2A 1A
10ms 20ms 50ms 100ms 200ms 500ms 1s 2s 5s Surge Current Duration
ORDERING INFORMATION 100 pcs. minimum

P.S. Specify maximum time for “D” and “P” version.

MOUNTING

AS-D

SERIES

Input Power S1

Function A:

Delay on Make

Output

Function A When input power is applied, timing t begins. At the end of the preselected time, the solid state SCR output turns on. The output turns off when the input power is removed, resetting the timer for the next cycle.

WIRING DIAGRAM:

QAS-D
470K
+- +-

LOAD

LOAD

INPUT

INPUT

Note Available with internal potentiometer in AS-P Series
100S

TIME RANGE
220 AD

INPUT POWER

Q = Encapsulated

AS = fixed time AS-D = remote potentiometer AS-P = internal potentiometer

AS = Fixed sec - 120 min AS-D = sec - 60 min. 10:1 Ratio AS-P = sec - 10 sec
1-100 sec maintain 100:1 ratio
24AD = 24 VAC/DC 110AD = 110 VAC/DC 220AD = 220 VAC/DC
1 AMP
2/46a

Products and specifications subject to change without notice.

Order/Technical Support Tel 800 677-5311 / FAX 800 677-3865 /

TIMERS

QBS SERIES

SINGLE SHOT TIMER

QCS SERIES

DELAY ON BREAK TIMER

UL listed CSA recognized
• CMOS Technology
• Epoxy Encapsulated
• x Compact Size
• Quick Connect Terminals

TIMERS

Input Power S1
ORDERING INFORMATION 100 pcs. minimum

DIMENSIONS See page 4-34

MOUNTING

SERIES

TIME RANGE
110A

INPUT POWER

Q = Encapsulated 2/46b

CS = Fixed time BS = Fixed time CS-D = Remote potentiometer BS-D = Remote potentiometer CS-P = Internal potentiometer BS-P = Internal potentiometer

CS/BS = Fixed time CS-D = sec. - 120 min BS-D = sec. - 120 min. maintain 10:1 ratio B or CSP = - 10 sec. or min
1 - 100 sec. or min. maintain 100:1 ratio
24A = 24 VAC 48A = 48 VAC 110A = 110 VAC 220A = 220 VAC

Products and specifications subject to change without notice.

Order/Technical Support Tel 800 677-5311 / FAX 800 677-3865 /
1 AMP

TIMERS

QDS SERIES

REPEAT CYCLE

QHS SERIES

INTERVAL ELECTRONIC TIMER

UL listed CSA recognized
• Consistent Repeat Cycle
• Multiple Voltage
• Square Cases
• Fixed and Variable Time Ranges

TIMERS

Function D:

Function H:

Function H The solid state output turns on when the input power

Recycling

Interval Timer

S1 is applied. The output turns off at the end of time T . The timer

Input
is reset when the input power is removed.

Power S1

Function D When input power S1 is applied, the sold state output

Output
turns on immediately for the time period specified. It then turns OFF

T1 T2
t for that same time period and repeats continuously while power is
applied.

SPECIFICATIONS:

Input 24 VAC, 48 VAC, 110 VAC 220 VAC, ±15%, 50/60 Hz

Maximum power consumption 24 VAC VA 48 VAC VA 110 VAC VA 220 VAC VA
ORDERING INFORMATION 100 pcs. minimum

DIMENSIONS See page 4-34

MOUNTING

SERIES
10 min

TIME RANGE

INPUT POWER

Q = Encapsulated

DS = Fixed time DS-D = Remote potentiometer

HS = Fixed time HS-D = Remote potentiometer DS-P = Internal potentiometer HS-P = Internal potentiometer

DS/HS = Fixed .1s - 120 min. DS-D/HS-D = sec - 120 min. maintaining 10:1 ratio DS-P/HS-P = sec or min
1-100 sec. or min. maintain 100:1 ratio
24A = 24 VAC 48A = 48 VAC 110A = 110 VAC 220A = 220 VAC
1 AMP
2/46c

Products and specifications subject to change without notice.

Order/Technical Support Tel 800 677-5311 / FAX 800 677-3865 /
More datasheets: QAS1S110ADL | QCS20M110AL | QCS10S110AL | QCS20S220AL | QAS4M220ADL | QDS45S220A | QHS12H110A | QASP20M220A | QCS20S110A | QASP5M220AL


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived QAS120M220A Datasheet file may be downloaded here without warranties.

Datasheet ID: QAS120M220A 507184