mm DIN rail mounting TUR1 Part number 88865105
Part | Datasheet |
---|---|
![]() |
88865385 (pdf) |
Related Parts | Information |
---|---|
![]() |
88865265 |
![]() |
88865115 |
![]() |
88865155 |
![]() |
88865185 |
![]() |
88865300 |
![]() |
88865215 |
![]() |
88865303 |
![]() |
88865103 |
![]() |
88865105 |
![]() |
88865125 |
![]() |
88865135 |
![]() |
88865145 |
![]() |
88865175 |
![]() |
88865305 |
PDF Datasheet Preview |
---|
22/10/2012 mm DIN rail mounting TUR1 Part number 88865105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply to the control input 3-wire sensor control option Part numbers Type Functions 88 865 105 TUR1 A - At - B - C - H - Ht - Di - D - Ac - Bw 88 865 115 TAR1 A - At 88 865 125 TBR1 B 88 865 135 TCR1 C 88 865 145 THR1 H - Ht 88 865 155 TLR1 Li - L 88 865 175 TQR1 Q 88 865 100 TUR4 A - At - B - C - H - Ht - Di - D - Ac - Bw 88 865 103 TUR3 A - At - B - C - H - Ht - Di - D - Ac - Bw 88 865 503 TURc3 A - At - B - C - H - Ht - Di - D - Ac - Bw 88 865 185 TXR1 Ad - Ah - N - O - P- Pt - TL - Tt - W 88 865 305 TU2R1 A - At - B - C - H - Ht - Di - D - Ac -Bw 88 865 215 TA2R1 A - At 88 865 265 TK2R1 K 88 865 300 TU2R4 A - At - B - C - H - Ht - Di - D - Ac - Bw 88 865 176 TQR6 Q Star / Delta 88 865 303 TU2R3 A, B, C, H, Di, Ac, BW + At, Ht, D 88 865 385 TX2R1 Ad - Ah - N - O - P - Pt - TL - Tt - W Timing s Output 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 changeover relay 1 change over relay 2 timed changeover relays 2 changeover relays 2 change over relays 2 timed relays changeover relays 1 change over relays 2 timed changeover relays 2 timed changeover relays Nominal rating 8A Connections Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Spring terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals Supply voltage 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 12 V AC / DC 12 V AC / DC 12 V AC / DC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 24 V DC / 24 V AC 12 V AC / DC 230 V AC 12 V AC/DC 24 V DC / 24 V AC Specifications Timing ranges 7 ranges Repetition accuracy with constant parameters Drift Temperature Drift Voltage Display accuracy according to IEC/EN 61812-1 Minimum pulse duration typically relay version Minimum pulse duration typically solid state version Minimum pulse duration typically relay version under load Maximum reset time by de-energisation typically relay version Maximum reset time by de-energisation typically solid state version Immunity from micro power cuts typical Supply Multi-voltage power supply Frequency Hz Operating range Operator factor Max. absorbed power Output specification 1 or 2 changeover relays, AgNi cadmium-free Rated power Maximum breaking current Minimum breaking current Voltage breaking capacity Electrical life operations 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h TK2R1 0.6s - 2.5s - 20s - 160 s ± % IEC/EN 1812-1 ± 0,05 % / °C ± % / V ± 10 % / 25 °C 30 ms 50 ms 100 ms 100 ms 350 ms > 10 ms Depending on version 50 / 60 85 to 110 % Un 85 to 120 % Un for 12V AC/DC 100 % 0,6 W 24 V AC/DC 1,5 W 230 V AC 32 VA 230 V AC 2000 VA/80 W 2000 VA/80 W 8 A AC 8A DC 10 mA / 5 V DC 250 V AC/ DC 10 5 operations 8 A 250 V resistive Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 Mechanical life operations Breakdown voltage acc. to IEC/EN 61812-1 Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1 5x106 kV /1 min / 1 mA / 50 Hz 5 kV, wave / 50 us Solid state output Rated power Derating Maximum admissible current Minimum breaking current Leakage current Voltage breaking capacity Maximum voltage drop at terminals Electrical life operations Mechanical life operations Breakdown voltage acc. to IEC/EN 60664-1, IEC 60255-5 Input type 0,7 A AC/DC 20 °C 0,5 A UL 5 mA / °C 20 A 10 ms 10 mA < 5 mA 250 V AC/ DC 3 wire 4V - 2 wire 8V 108 kV to 1 mA / 1 min Volt-free contact 3-wire PNP output control option residual voltage 0.4V whatever the timer power supply General characteristics Conformity to standards IEC/EN 61812-1 IEC/EN 61000-6-1 IEC/EN 61000-6-2 IEC/EN 61000-6-3 IEC/EN 61000-6-4 Certifications CE, UL, cUL, CSA, GL Temperature limits use °C Temperature limits stored °C Installation category acc. to IEC/EN 60664-1 |
More datasheets: ASA01A36-L | ASA01F18-L | ASA00CC18-L | ASA00AA18-L | FPN530A | FPN530 | 88865265 | 88865115 | 88865155 | 88865185 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 88865385 Datasheet file may be downloaded here without warranties.