EWS / EWS2 phase sequence and loss of phase EWS Part number 84892299

Part Datasheet
84892299 84892299 84892299 (pdf)
PDF Datasheet Preview
22/10/2012

EWS / EWS2 phase sequence and loss of phase EWS Part number 84892299

Space savings, accurate measurement and optimized functions all improve the efficiency of your electrical installation. Control You simply install your EWS phase control relay and without any adjustment you can monitor the loss or inversion of one of the phases. Safety The EWs range enables you to choose the level of safety for your installation by using versions with 1, 2 or 3 output changeovers. Self-powered Simple to install, EWS control relays use the controlled mains supply for their own power supply voltage.

Part numbers

Type 84 892 299 EWS 84 873 004 EWS2

Specifications

Operating range Operating range Frequency Maximum consumption Output relay Type of contacts Nominal rating Maximum breaking voltage Max. voltage Nominal breaking capacity Min. breaking current Electrical life number of operations Maximum rate at full load Mechanical life operations Pick-up delay T1 Turn-off delay T2 Connection capacity - without ferrule

Connection capacity - with ferrule Max. tightening torque Operating temperature range oC Storage temperature 0C Housing material Protection IEC 60529 - Casing Protection IEC 60529 - Term. block Dielectric strength IEC 60255-5 Insulation coordination IEC/EN 60664-1 Weight g

Principles

Output relay 1 changeover 2 changeovers
3 AC V 50 / 60 Hz +/- 1 Hz 25 VA

No cadmium 8A 250 V AC 440 V AC 2000 VA 10 mA / 5 V AC 12 105 at 8A/250 VAC 360 operations / hour 2 x 107 200 ms 300 ms in the event of phase failure 2 x 2,5 mm2 1 x 4 mm2 2 x 1,5 mm2 1 Nm screw M3 / IEC 947-1
-30 Self-extinguishing IP40 IP20 2,5 KV / 1 mn / 1 mA / 50 Hz Overvoltage category III, degree of pollution 3 110

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
22/10/2012

Operating principle EWS/EWS2 relays monitor the correct sequencing of phases L1, L2 and L3 as well as the loss of one of these phases. When the phase sequence is correct, the output relay is energised, indicated by a yellow LED. The relay de-energises LED off if one of the following faults occurs Incorrect sequence of phases at terminals L1, L2 and L3 Total loss of one phase or all three phases loss of phase detection threshold < 50 VAC

Legend

Phase L1

Phase L2

Phase L3

Relay

Dimensions mm EWS / EWS2

Connections EWS

Connections EWS Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
22/10/2012

Legend

Isolating switch

Contactor

Alarm

Auxiliary power supply for contactor coil and signalling

Connections EWS Monitoring of three-phase motor. Manual re-engage after disappearance of the fault.

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
22/10/2012

Surveillance moteur triphasé Réenclenchement manuel après disparition du défaut. defecto

Legend

Isolating switch

Contactor

Alarm

Auxiliary power supply for contactor coil and signalling

Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected