BXRA-27E3500-F-00

BXRA-27E3500-F-00 Datasheet


BXRA-27X-3500-F, BXRA-27X4000-H, BXRA-27x7000-J, BXRA-30X3500-F, BXRA-30X4000-H, BXRA-30X7000-J, BXRA-35X3500-F, BXRA-35X4000 -H, BXRA-35X7000-J, BXRA-40X4000-F, BXRA-40E4500-H, BXRA-40E7500-J, BXRA-5XC4500-F, BXRA-5XC5300-H, BXRA-5XC9000-J

Part Datasheet
BXRA-27E3500-F-00 BXRA-27E3500-F-00 BXRA-27E3500-F-00 (pdf)
Related Parts Information
BXRA-30G3500-F-00 BXRA-30G3500-F-00 BXRA-30G3500-F-00
BXRA-35E3500-F-00 BXRA-35E3500-F-00 BXRA-35E3500-F-00
BXRA-40E4000-F-00 BXRA-40E4000-F-00 BXRA-40E4000-F-00
BXRA-30E3500-F-00 BXRA-30E3500-F-00 BXRA-30E3500-F-00
BXRA-27G3500-F-00 BXRA-27G3500-F-00 BXRA-27G3500-F-00
PDF Datasheet Preview
Bridgelux RS Array Series

Product Data Sheet DS25

BXRA-27X-3500-F, BXRA-27X4000-H, BXRA-27x7000-J, BXRA-30X3500-F, BXRA-30X4000-H, BXRA-30X7000-J, BXRA-35X3500-F, BXRA-35X4000 -H, BXRA-35X7000-J, BXRA-40X4000-F, BXRA-40E4500-H, BXRA-40E7500-J, BXRA-5XC4500-F, BXRA-5XC5300-H, BXRA-5XC9000-J

Introduction

The Bridgelux family of LED Array products delivers high performance, compact and cost-effective solidstate lighting solutions to serve the general lighting market. These products combine the higher efficacy, lifetime, and reliability benefits of LEDs with the light output levels of many conventional lighting sources. The Bridgelux RS Array Series has been specified to enable lamp and luminaire designs with comparable performance to existing high wattage CFL and HID conventional light sources for retail, commercial, industrial and outdoor/street lighting applications. Bridgelux Arrays are ideal for all types of light-on-demand applications, where they can be instantaneously and smoothly dimmed up or down without any effect on lifetime, unlike traditional CFL and HID light sources.

Bridgelux RS Array series are a high performance alternative to conventional solid state solutions, delivering between 3,000 and 10,000 lumens under application conditions in warm, neutral and cool white color temperatures. These compact high flux density light sources deliver uniform high quality illumination without pixilation or the multiple shadow effect caused by LED component based solutions, enabling excellent beam control for precision lighting.

LED array solutions reduce system complexity and enable miniaturized cost-effective designs. Luminaire designs incorporating these LED Arrays deliver system level performance comparable to 42-55 Watt CFL, 35-90 Watt low pressure sodium, 70-150 Watt high pressure sodium or 70-200 Watt metal halide based luminaires and feature increased system level and service life. Typical applications include retail lighting, commercial down lights, high bay, outdoor and street lights, and entertainment lighting.
• Compact high flux density light source
• Uniform high quality illumination
• Minimum 70, 80 and 90 CRI options
• Streamlined thermal path
• Energy Star / ANSI compliant color
binning structure with 3SDCM options
• More energy efficient than incandescent,
halogen and fluorescent lamps
• Low voltage DC operation
• Instant light with unlimited dimming
• 5-Year warranty
• RoHS compliant and Pb free
• Enhanced optical control
• Clean white light without pixilation
• High quality true color reproduction
• Significantly reduced thermal resistance
and increased operating temperatures
• Uniform consistent white light
• Lower operating costs
• Increased safety
• Easy to use with daylight and motion
detectors to enable increased energy savings
• Reduced maintenance costs
• Environmentally friendly, no disposal issue
101 Portola Avenue, Livermore, CA 94551
• Tel 925 583-8400
• Fax 925 583-8401


Table of Contents

Product Nomenclature Average Lumen Maintenance Characteristics IES LM-80 Test Data Environmental Compliance UL Recognition Minor Product Change Policy Cautionary Statements Selection Guide Color Control Options Flux Characteristics Optical Characteristics Electrical Characteristics Absolute Minimum and Maximum Ratings Typical Performance at Alternative Drive Currents Typical Performance at Alternative Drive Currents continued Mechanical Dimensions Typical Radiation Pattern Wavelength Characteristics at Rated Test Current, Tj=25°C Typical Relative Luminous Flux vs. Current, Tj=25°C Typical Light Output Characteristics vs. Temperature Forward Current Characteristics Color Binning Information Design Resources
3 4 6 7 8 9 10 11 12 13 15 16 17 18 20 22 24 27

Bridgelux RS Array Series Product Data Sheet DS25 10/17/2012

Page 2 of 28

Product Nomenclature

The part number designation for Bridgelux LED Arrays is explained as follows:

BXRA AB C DEFG H IJ - KLM

Where:

BXRA Designates product family

AB Designates the nominal ANSI color temperature 27 = 2700K 30 = 3000K, etc.

C - Designates minimum CRI C = 70, E = 80, G = 90

DEFG - Designates Nominal Flux 4000 = 4000lm, 7000 = 7000lm, 9000 = 9000lm, etc.

H Designates array configuration

IJ Designates CCT Bin options 3000K as an example 00 = Full ANSI Q3, Q4, R3, R4 03 = 3 SDCM

KLM Designates wire option if available

Average Lumen Maintenance Characteristics

Bridgelux projects that its family of LED Array products will deliver, on average, greater than 70% lumen maintenance after 50,000 hours of operation at the rated forward test current. This performance assumes constant current operation with case temperature maintained at or below 85°C. For use beyond these typical operating conditions please consult your Bridgelux sales representative for further assistance.

These projections are based on a combination of package test data, semiconductor chip reliability data, a fundamental understanding of package related degradation mechanisms, and performance observed from products installed in the field using Bridgelux die technology. Bridgelux conducts lumen maintenance tests per LM80. Observation of design limits is required in order to achieve this projected lumen maintenance.

IES LM-80 Test Data

Bridgelux has carried out extensive testing on multiple LED arrays according to the IES LM-80 test protocols. LM80 data is available to support all BXRA LED array products.

The IES LM-80 qualification test method is required for an LED light source. The LM-80 test method does not apply to an LED luminaire light fixture. LM-80 is a rigorous test procedure that has been designed to provide LED light source test data to support an ENERGY STAR rating for a luminaire light fixture.

When a manufacturer requires an ENERGY STAR rating for a fixture, the manufacture must have the luminaire light fixture tested to LM-79 by an accredited test facility. This test ensures that the fixture meets the photometric performance required for the ENERGY STAR rating under the specified operating conditions of the fixture.

Bridgelux RS Array Series Product Data Sheet DS25 10/17/2012
More datasheets: FAN3850TUC15X35 | M39131 SL002 | M39131 SL005 | M39131 SL001 | B32529D5335J000 | 19210-11 | 17000208A | BXRA-30G3500-F-00 | BXRA-35E3500-F-00 | BXRA-40E4000-F-00


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BXRA-27E3500-F-00 Datasheet file may be downloaded here without warranties.

Datasheet ID: BXRA-27E3500-F-00 522349