BXRA-N0400-00000

BXRA-N0400-00000 Datasheet


The base product part number BXRA-ABCDE is indicated on each individual unit, printed on the bottom of the array.

Part Datasheet
BXRA-N0400-00000 BXRA-N0400-00000 BXRA-N0400-00000 (pdf)
Related Parts Information
BXRA-W0800-00000 BXRA-W0800-00000 BXRA-W0800-00000
BXRA-W0400-00000 BXRA-W0400-00000 BXRA-W0400-00000
BXRA-C0400-00000 BXRA-C0400-00000 BXRA-C0400-00000
BXRA-C0800-00000 BXRA-C0800-00000 BXRA-C0800-00000
BXRA-N0800-00000 BXRA-N0800-00000 BXRA-N0800-00000
BXRA-C1200-00000 BXRA-C1200-00000 BXRA-C1200-00000
BXRA-W1200-00000 BXRA-W1200-00000 BXRA-W1200-00000
BXRA-N1200-00000 BXRA-N1200-00000 BXRA-N1200-00000
BXRA-C2000-00000 BXRA-C2000-00000 BXRA-C2000-00000
PDF Datasheet Preview
Bridgelux LED Arrays

Introduction

The Bridgelux family of LED Array products delivers high performance, compact and cost-effective solidstate lighting solutions to serve the general lighting market. These products combine the higher efficiency, lifetime, and reliability benefits of LEDs with the light output levels of many conventional lighting sources.

Product options are tailored to match light output levels of conventional light sources, delivering between 400 and 2000 lumens under application conditions in cool, neutral and warm white colors. In order to satisfy system design requirements, the Bridgelux LED Arrays are specified to deliver these values hot, or under assumed typical use conditions, eliminating the need of incorporating additional sources to account for thermal degradation.

Various configurations are available allowing the product to be optimized on efficacy, CRI, light output, cost, or a combination of these attributes. These high lumen output integrated sources reduce system design complexity, enabling miniaturized cost-effective lamp and luminaire designs. Typical applications include task, accent, spot, track, down light, wide area and security lighting.
• Compact high flux density light source
• Uniform high quality illumination
• Streamlined thermal path
• Energy Star / ANSI compliant binning
structure
• More energy efficient than
incandescent, halogen and some fluorescent lamps
• Low voltage DC operation
• Instant light with unlimited dimming
• Long operating life
• RoHS compliant and Pb free
• Enhanced optical control
• Clean white light
• Significantly reduced thermal resistance
and increased operating temperatures
• Uniform consistent white light
• Lower operating costs
• Increased safety
• Easy to use with daylight and motion
detectors to enable increased energy savings
• Reduced maintenance costs
• Environmentally friendly, no disposal issues
1170 Sonora Ct, Sunnyvale, CA 94086
• Tel 408 990-7500
• Fax 408 990-7501


Table of Contents Product Nomenclature Average Lumen Maintenance Characteristics Environmental Compliance Minor Product Change Policy Cautionary Statements Case Temperature Measurement Point Flux Characteristics Optical Characteristics Electrical Characteristics Absolute Minimum and Maximum Ratings Mechanical Dimensions Typical Radiation Pattern Wavelength Characteristics Typical Relative Luminous Flux vs. Current Typical Light Output Characteristics Over Temperature Typical Chromaticity Characteristics Over Temperature Typical Forward Current Characteristics Current Derating Curves Product Binning Luminous Flux Binning Information Color Binning Information Mechanical Assembly and Handling Product Packaging and Labeling Packaging Tube Design

Bridgelux LED Array Data Sheet DS10 3/12/09

Page 3 4 5 6 7 8 9 11 12 14 16 17 18 21 26 27 30 31 33

Page 2 of 34

Product Nomenclature

The part number designation for Bridgelux LED Arrays is explained as follows:

Where:

B X R A designates product family

A designates color, C for Cool White, N for Neutral White, and W for Warm White

B C designates array product flux, 04 for a 400 lumen array, 08 for a 800 lumen array, 12 for a 1200 lumen array, and 20 for a 2000 lumen array

D E reserved for future product designations
0 designates the standard product option, reserved for future product designations

The base product part number BXRA-ABCDE is indicated on each individual unit, printed on the bottom of the array.

Average Lumen Maintenance Characteristics

Bridgelux projects that its family of LED Array products will deliver, on average, greater than 70% lumen maintenance after 50,000 hours of operation at the rated forward test current. This performance assumes constant current operation with case temperature maintained at or below 70°C. For use beyond these typical operating conditions please consult your Bridgelux sales representative for further assistance.

These projections are based on a combination of package test data, semiconductor chip reliability data, a fundamental understanding of package related degradation mechanisms, and performance observed from products installed in the field using Bridgelux die technology. Bridgelux conducts lumen maintenance tests per LM80. Observation of design limits is required in order to achieve this projected lumen maintenance.

Environmental Compliance

Bridgelux is committed to providing environmentally friendly products to the solid-state lighting market. Bridgelux LED Arrays are compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the RoHS directive. Bridgelux will not intentionally add the following restricted materials to array products lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls PBB or polybrominated diphenyl ethers PBDE .

Bridgelux LED Array Data Sheet DS10 3/12/09

Page 3 of 34

Minor Product Change Policy

The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization.

CAUTION CONTACT WITH OPTICAL AREA

Contact with the resin area should be avoided. Applying stress to the resin area can result in damage to the product.

CAUTION EYE SAFETY

Eye safety classification for the use of Bridgelux LED Arrays is contained in the CIE S 009/E2002 Photobiological Safety of Lamps and Lamp Systems specification. Bridgelux LED Arrays are classified under section 6 lamp classification as Risk Group 2 Moderate Risk . Please use appropriate precautions. It is important that employees working with LEDs are trained to use them safely. Luminaire manufacturers should refer to CIE S 009/E2002 to establish the classification of their product.

CAUTION RISK OF BURN

Do not touch the LED Array or resin area during operation. Allow the LED Array to cool for a sufficient period of time before handling. The LED Array may reach elevated temperatures such that it can burn skin when touched.

Case Temperature Measurement Point
More datasheets: TIPL770-S | BXRA-W0800-00000 | BXRA-W0400-00000 | BXRA-C0400-00000 | BXRA-C0800-00000 | BXRA-N0800-00000 | BXRA-C1200-00000 | BXRA-W1200-00000 | BXRA-N1200-00000 | BXRA-C2000-00000


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BXRA-N0400-00000 Datasheet file may be downloaded here without warranties.

Datasheet ID: BXRA-N0400-00000 522345