2015-15-SMC-RPLF

2015-15-SMC-RPLF Datasheet


This series is obsolete and not recommended for new designs. The 2017 Series is the suggested alternative.

Part Datasheet
2015-15-SMC-RPLF 2015-15-SMC-RPLF 2015-15-SMC-RPLF (pdf)
Related Parts Information
2015-42-SMC-RPLF 2015-42-SMC-RPLF 2015-42-SMC-RPLF
2015-15-A-RPLF 2015-15-A-RPLF 2015-15-A-RPLF
2015-15-SMH-RPLF 2015-15-SMH-RPLF 2015-15-SMH-RPLF
2015-23-A-RPLF 2015-23-A-RPLF 2015-23-A-RPLF
2015-23-SMC-RPLF 2015-23-SMC-RPLF 2015-23-SMC-RPLF
2015-35-A-RPLF 2015-35-A-RPLF 2015-35-A-RPLF
2015-50-A-RPLF 2015-50-A-RPLF 2015-50-A-RPLF
2015-42-A-RPLF 2015-42-A-RPLF 2015-42-A-RPLF
2015-60-A-RPLF 2015-60-A-RPLF 2015-60-A-RPLF
2015-09-SMC-RPLF 2015-09-SMC-RPLF 2015-09-SMC-RPLF
2015-60-SMH-RPLF 2015-60-SMH-RPLF 2015-60-SMH-RPLF
2015-60-SMC-RPLF 2015-60-SMC-RPLF 2015-60-SMC-RPLF
2015-42-SMH-RPLF 2015-42-SMH-RPLF 2015-42-SMH-RPLF
2015-50-SMC-RPLF 2015-50-SMC-RPLF 2015-50-SMC-RPLF
2015-50-SMH-RPLF 2015-50-SMH-RPLF 2015-50-SMH-RPLF
2015-35-SMC-RPLF 2015-35-SMC-RPLF 2015-35-SMC-RPLF
2015-09-A-RPLF 2015-09-A-RPLF 2015-09-A-RPLF
2015-35-SMH-RPLF 2015-35-SMH-RPLF 2015-35-SMH-RPLF
2015-23-SMH-RPLF 2015-23-SMH-RPLF 2015-23-SMH-RPLF
2015-09-SMH-RPLF 2015-09-SMH-RPLF 2015-09-SMH-RPLF
PDF Datasheet Preview
*RoHS COMPLIANT

LEAD FREE
n GDT technology n Flexible mounting options n Volume- and space-saving design n Improved impulse performance n 5 kA 8/20 µs rated n UL Recognized n RoHS compliant*

This series is obsolete and not recommended for new designs. The 2017 Series is the suggested alternative.
2015 Series Gas Discharge Tube Surge Arrestor with Technology

Characteristics

Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.

Characteristic
2015-09

Model No.
2015-15
2015-23

DC Sparkover ±20 % 100 V/s 1
150 V
230 V

DC Sparkover End-of-Life Values 2

OBSOLETE Maximum 99 % of values

Minimum 99 % of values Impulse Sparkover Voltage 3
100 V/µs Typical 1 kV/µs Typical

Characteristic DC Sparkover ±20 % 100 V/s 1 DC Sparkover End-of-Life Values 2

Maximum 99 % of values Minimum 99 % of values Impulse Sparkover Voltage 3 100 V/µs Typical 1 kV/µs Typical
<120 V > 65 V
400 V 700 V
2015-42 420 V
<550 V >360 V 650 V 850 V
<195 V >110 V
400 V 650 V

Model No. 2015-50 500 V
<650 V >400 V
700 V 900 V
<300 V >170 V
450 V 650 V
2015-60 600 V
<780 V >450 V 750 V 950 V

Insulation Resistance IR ...................100 V 50 V for Model > 1 GΩ Glow ~ 70 V Arc ~ 10 V

Impulse Discharge Current.................10000 A, 8/20 1 operation
5000 A, 8/20 > 10 operations
1000 A, 10/350 1 operation
100 A, 10/1000 µs > 300 operations
10 A, 10/1000 µs >1500 operations

Glow-Arc Transition Current < A