This series is obsolete and not recommended for new designs. The 2017 Series is the suggested alternative.
Part | Datasheet |
---|---|
![]() |
2015-09-A-RPLF (pdf) |
Related Parts | Information |
---|---|
![]() |
2015-42-SMC-RPLF |
![]() |
2015-15-A-RPLF |
![]() |
2015-15-SMC-RPLF |
![]() |
2015-15-SMH-RPLF |
![]() |
2015-23-A-RPLF |
![]() |
2015-23-SMC-RPLF |
![]() |
2015-35-A-RPLF |
![]() |
2015-50-A-RPLF |
![]() |
2015-42-A-RPLF |
![]() |
2015-60-A-RPLF |
![]() |
2015-09-SMC-RPLF |
![]() |
2015-60-SMH-RPLF |
![]() |
2015-60-SMC-RPLF |
![]() |
2015-42-SMH-RPLF |
![]() |
2015-50-SMC-RPLF |
![]() |
2015-50-SMH-RPLF |
![]() |
2015-35-SMC-RPLF |
![]() |
2015-35-SMH-RPLF |
![]() |
2015-23-SMH-RPLF |
![]() |
2015-09-SMH-RPLF |
PDF Datasheet Preview |
---|
*RoHS COMPLIANT LEAD FREE n GDT technology n Flexible mounting options n Volume- and space-saving design n Improved impulse performance n 5 kA 8/20 µs rated n UL Recognized n RoHS compliant* This series is obsolete and not recommended for new designs. The 2017 Series is the suggested alternative. 2015 Series Gas Discharge Tube Surge Arrestor with Technology Characteristics Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards. Characteristic 2015-09 Model No. 2015-15 2015-23 DC Sparkover ±20 % 100 V/s 1 150 V 230 V DC Sparkover End-of-Life Values 2 OBSOLETE Maximum 99 % of values Minimum 99 % of values Impulse Sparkover Voltage 3 100 V/µs Typical 1 kV/µs Typical Characteristic DC Sparkover ±20 % 100 V/s 1 DC Sparkover End-of-Life Values 2 Maximum 99 % of values Minimum 99 % of values Impulse Sparkover Voltage 3 100 V/µs Typical 1 kV/µs Typical <120 V > 65 V 400 V 700 V 2015-42 420 V <550 V >360 V 650 V 850 V <195 V >110 V 400 V 650 V Model No. 2015-50 500 V <650 V >400 V 700 V 900 V <300 V >170 V 450 V 650 V 2015-60 600 V <780 V >450 V 750 V 950 V Insulation Resistance IR ...................100 V 50 V for Model > 1 GΩ Glow ~ 70 V Arc ~ 10 V Impulse Discharge Current.................10000 A, 8/20 1 operation 5000 A, 8/20 > 10 operations 1000 A, 10/350 1 operation 100 A, 10/1000 µs > 300 operations 10 A, 10/1000 µs >1500 operations Glow-Arc Transition Current < A |
More datasheets: 2015-50-A-RPLF | 2015-42-A-RPLF | 2015-60-A-RPLF | 2015-09-SMC-RPLF | 2015-60-SMH-RPLF | 2015-60-SMC-RPLF | 2015-42-SMH-RPLF | 2015-50-SMC-RPLF | 2015-50-SMH-RPLF | 2015-35-SMC-RPLF |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 2015-09-A-RPLF Datasheet file may be downloaded here without warranties.