Models H100 Light Meter
Part | Datasheet |
---|---|
![]() |
H100 (pdf) |
PDF Datasheet Preview |
---|
INSTRUCTION MANUAL Models H100 Light Meter Table of Content Product Introduction 3 1-1 Features 3 1-2 Applications 3 Safety Information 4 2-1 Cautions 4 2-2 Safety Symbols 4 5 Operation Instructions 7 4-1 Unit Diagram 7 4-2 Measuring Procedure 8 4-3 Zero Adjust 8 4-4 Data Hold 8 4-5 Peak Hold 8 4-6 Data Record 9 Auto Power Off Disable 9 RS232 PC Serial Interface Information 10 Battery Replacement 11 Service Information 12 Warranty Information 13 To see all available accessories and downloadable software, please visit Product Introduction 1-1 Features Two year warranty Large LCD display with bar graph Wide measurement ranges 40.00/400.0/4,000/40,000/400,000lux Display resolution 0.04lux to 100lux, 0.01ft-cd to 10ft-cd lux or foot-candle unit selection 4 light type select Tungsten, Fluorescent, Sodium or Mercury Sensor meet C.I.E. spectrum, 2 filters Data hold, Record max., min. DC 1.5V battery UM-4, AAA x 6 Longer battery life compared to 9V 1-2 Applications Science Experiments Photography Manufacturing Agriculture Artistry Safety Information Read the following safety information carefully before attempting to operate or service the meter. Only qualified personnel should perform repairs or servicing not covered in this manual. 2-1 Cautions! DO NOT submerge the products mentioned in this manual in water or any other types of liquids. This product is not designed for use in medical applications. The product can only be used to measure body temperature simply for reference. 2-2 Safety Symbols Dangerous, refer to this manual before using the meter. Conforms to requirements of European Union and European Fare Trade Association EFTA . Battery level is low. Don’t dispose this product as unsorted municipal waste. This instrument conforms to the following standards EN61326 Electrical equipment for measurement, control and laboratory use. IEC61000-4-2 Electrostatic discharge immunity test. IEC61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test. IEC61000-4-8 Power frequency magnetic field immunity test. Specifications Display Measurement Ranges Unit of Measurement Measurable Lighting Sources Sensor Display values: Unit fc foot-candle Accuracies: fc foot-candle 5 Digit LCD with bar graph indicator 40.00/400.0/4,000/40,000/400,000lux lux or Foot-Candle fc Tungsten, Fluorescent, Sodium or Mercury Lamps Photo diode & color correction filter, spectrum meets C.I.E. Cosine correction factor standards Range 40 400 4,000 40,000 400,000 4 40 400 4,000 40,000 In Range Display 0 to Lux to Lux 360 to 4,000 Lux 3,600 to 40,000 Lux 10,000 to 400,000 Lux 0 to Fc to Fc to Fc 335 to 3,720 Fc 930 to 37,200 Fc Resolution Lux 1 Lux 1 Lux 10 Lux 100 Lux Fc 1 Fc 1 Fc 10 Fc Range 40 400 4,000 40,000 400,000 4 40 400 4,000 40,000 Accuracy** ± 3% rdg + % F.S. < 100,000 Lux ± 3% rdg + % F.S. * ± 3% rdg + % F.S. < 9,300 Fc ± 3% rdg + % F.S. * Zero Adjust Peak Hold Data Hold Memory Power Off Over and Under Range Indicator 40.00lux range only Displays peak value Display freeze Saves MAX. or MIN values with recall Auto or manual control Over range indicator " _ " top of the display Under range indicator "_" bottom of the display Data Output RS-232 Serial data output Operating Environment 32° to 122°F 0° to 50°C , <80% R.H. Power Supply 6 Pieces of DC 1.5V Batteries UM4, AAA or equivalent Weight approx. 0.79lbs. 357g Dimensions approx. Main instrument x 174 x 68 x 42mm |
More datasheets: GPMP600-28 | GPMP700-48 | GPMP600-24 | GPMP600-24G | EPMHH32E | 12-21SURC/S530-A3/TR8 | 19039646A | 17523 | 4310-018LF | 16-000010 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived H100 Datasheet file may be downloaded here without warranties.