CUSTOMER DESCRIPTION MODEL NO. DAVID NO. ISSUE DATE ISSUE EDITON

AC ADAPTOR DP48-1201000 C169-75 2010/04/08

FOR APPROVAL SHEET
1.According to our ISO-9002 system, We cannot process your P.O before you
approve this specification by signing, stamping and returning the“Declaration of
approval”Section of this page.
2.This document is property of System Connection Inc is prepared for the use

Disclosure or distribution of part or whole of this documemt without
the written permission of System Connection Inc is strictly prohibited.

The whole specification including this and the Client’s Declaration of Approval
following pages have been carefully studied and
accepted andapproved by us with no query.

Page 2 Electrical Specification Page 3 Mechanical drawing Page 4 Construction Drawing

Authorized Signature & Company

Page 5 Materials List Page 6 Label specification

Page 7 Package Page 8 Sample test report

System Connection Inc.
441 EAST BAY BLVD. PROVO, UT 84606 USA TEL +001 801-765-9849

MODEL NO. DP48-1201000

System Connection Inc.

DAVID NO.

AC ADAPTOR

C169-75

Part EI-48 Current Diagram:
120VAC 60Hz

ISSUE DATE 2010/04/08
12VDC 1000mA
130℃ Construction:

Surface Damage. Rusting. Foam Flow or Air not Permitted. Lead tension test Lead must be withstand a pull kg for 30 seconds. Characteristics Primary rated voltage and frequency 120 VAC 60 Hz Secondary rating :with Tolerance ,At Input Voltage 120 VAC, 60 Hz

TEST POINT 3-4

Rated Voltage 12VDC ±5%

Rated Current DC 1000mA

Voltage Regulation No Load Voltage 17.5VDC MAX

Exciting Current Input Primary 120 V 60 Hz 80 mA MAX. No Load Hi-Pot test Apply 1500 VAC 3 mA 60 Seconds between the

Primary to Secondary and between Primary to Core. Apply 500 VAC , 3 mA 60 Seconds between Secondary to core. Insulation test 500 V DC 100 MΩ min, between winding to winding and core.

Humidity test Temp 25 ±5 ℃ relative humidity 91~95 % RH for 6 hours. After

Keeping 30 minutes following insulation must be larger than MΩ.

Temperature test Less than 75 ℃ for rated test with Resistance method. Adequate Standard UL/CUL

APPROVED BY RECHECKED BY

CHECKED BY REPORTED BY
2/10/4