RS-232 To RS-422 Converter

Model 422CON

This RS-232 to RS-422 converter converts unbalanced RS-232 signals to balanced RS-422 signals. The RS-422 Standard uses a balanced voltage digital interface to allow communications of 90K bits per second on cable lengths of 4000 feet. Ten receivers can be connected to any one driver for use in multi-drop systems.

The RS-232 port uses a male DB25 type of connector with pins 2 TD input and 3 RD output supported. Protective ground pin 1 and Signal Ground pin 7 are also connected. The RS-422 port uses a female DB-25 type of connector with the Send Data outputs on pins 2 and 14, and the Receive Data inputs on pins 5 and Protective Ground pin 1 and Signal Ground pin 7 are connected through to the RS-232 connector.

Interconnection of the converter with another RS-422 device:

The polarity of the two RS-422 lines must be correct. With no data being sent the RS-232 line should be
negative and the RS-422 "A"terminal should be negative with respect to the "B" terminal. If your equipment uses a
+ and - naming scheme, in most cases the A line will be connected to the "-", and the B line will be connected to

The wire recommended in the RS-422 Standard is number 24 AWG copper conductor, twisted-pair
telephone cable with a shunt capacitance of 16 pF per foot.

For long runs and/or high data rates it is recommended that the wires be terminated with a resistor at the
receive end. The twisted pair usually used has an impedance of about 100 ohms, therefore a 100 ohm resistor is
normally
used for the termination. The RS-422 side of the converter requires more power as the
transmission line is increased and as the termination resistor value is reduced, therefore it may be necessary to
use a termination resistor that is larger than 100 ohms.

The RS-422 driver has the ability to drive 10 RS-422 receivers connected in parallel. A system of multiple
receivers may require some experimentation with location and size of termination resistors, line lengths,
grounding, etc.

The RS-422 Standard recommends that Protective Ground pin 1 be connected to a good "green wire" ground. This may be already connected in your RS-232 equipment. Protective Ground and Signal Ground should be connected through to each end of the system and be connected to each other using a 100 ohm 1/2 watt resistor at one end only. If a shielded twisted pair is used the shield should be connected to Protective Ground.

DECLARATION OF CONFORMITY

Manufacturer’s Name:

B&B Electronics Manufacturing Company

Manufacturer’s Address:

P.O. Box 1040 707 Dayton Road Ottawa, IL 61350 USA

Model Numbers:
422CON

Description:

RS-422 Converter

Type:

Light industrial ITE equipment

Application of Council Directive 89/336/EEC

Standards:

EN 50082-1 IEC 801-2, IEC 801-3, IEC 801-4 EN 50081-1 EN 55022, IEC 1000-4-2 EN 61000 -4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11 ENV 50204 EN 55024

Robert M. Paratore, Director of Engineering

PRODUCT INFORMATION

International Office 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104 European Office Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445

B&B ELECTRONICS

Document No. 422CON0812 - pg. 2/2
More datasheets: 5851111 | 15006 | 32-01/T4C-4PRB | 74F64PC | 2303 | A8739EEETR-T | FDMS2508SDC | M5509 SL005 | M5509 SL002 | M5509 SL001


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 422CON Datasheet file may be downloaded here without warranties.

Datasheet ID: 422CON 521484