NFS110-7624J

NFS110-7624J Datasheet


NFS110 Series

Part Datasheet
NFS110-7624J NFS110-7624J NFS110-7624J (pdf)
Related Parts Information
NFS110-7602J NFS110-7602J NFS110-7602J
NFS110-7604PJ NFS110-7604PJ NFS110-7604PJ
NFS40-7615J NFS40-7615J NFS40-7615J
NFS110-7612J NFS110-7612J NFS110-7612J
NFS110-7601J NFS110-7601J NFS110-7601J
PDF Datasheet Preview
Embedded Power for Business-Critical Continuity

NFS110 Series

Single & Quad output
1 of 5

Total Power 80 - 110 W Input Voltage 85 - 264 Vac
120 - 370 Vdc # of Outputs Single, quad

Special Features
• x inch package
• Overvoltage and short circuit
protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011 conducted
emissions level B
• UL, VDE and CSA safety
approvals
• CE mark
• Available RoHS compliant
• 2 year warranty

Safety
• VDE0805/EN60950/
• IEC950/IEC1010

File No. 10401-3336-0213
• Licence No. 4001467 7
• UL1950 File No. E132002
• CSA C22.2 No. 950

File No. LR41062C

Electrical Specifications

Output Voltage adjustability:

Line regulation Overshoot/undershoot Temperature coefficient Overvoltage protection:

Output power limit Minimum output current Short circuit protection:

V o/p on multi’s V single output 12 V single output 15 V single output 24 V single output

LL to HL, FL All outputs on all units At turn-on

All outputs

Multi o/p V only V single output 12 V single output 15 V single output 24 V single output

Primary power limited

See Note 13

Burst mode operation
12 - 14 V 15 - 18 V 24 - 30 V
max.
±0.02%/°C

V ± V ± V ± V 22 V ± V 33 V ± V

Pin max. 160 W Pout min. 110 W 0A

Input voltage range:

Input frequency range Input surge current Safety ground leakage current:
230 Vac
110 Vac, 50 Hz 230 Vac, 50 Hz
85 - 264 Vac 120 - 370 Vdc
47 - 440 Hz 35 A
mA, max. mA, max.

All specifications are typical at nominal input, full load at 25 °C unless otherwise stated

Embedded Power for Business-Critical Continuity

EMC Characteristics Conducted emissions Radiated emissions ESD  air ESD contact Surge Fast transients Radiated immunity Conducted immunity General Specifications Hold-up time:
Ordering Information

Output Voltage

Max 1
+12 V

V IA +24 V IB 6
+12 V
-15 V

Output Currents Peak 2 20 A 9A A 20 A 9A A 20 A 9A A

Fan 3 10 A 5A 1A 10 A 5A 1A 10 A 5A 1A 9A A
3 of 5

Ripple 4
50 mV 120 mV 120 mV 50 mV 50 mV 240 mV 120 mV 120 mV 50 mV 150 mV 150 mV 50 mV 120 mV 150 mV 240 mV

Total Regulation 5
± ± ± ± ± ± ± ± ± ± ± ± ± ±

Model Numbers 13, 15, F NFS110-7601PJ 14

NFS110-7602PJ 6, 14

NFS110-7604PJ 14

NFS110-7612J 7,8 NFS110-7615J 7,8 NFS110-7624J 7,8

Notes 1 Convection cooled, 80 W maximum. 2 Peak outputs lasting less than 60 seconds with duty cycle less than Total
peak power must not exceed 110 W. 3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum. 4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor. 5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. 6 To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the following load condition must be true IA / IB 5, where IA = V output current, and IB = +24 V output current The +24 V output will maintain regulation under the following additional condition IA 5 A. 7 Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts natural convection or 110 Watts forced air . 8 Power fail detect not available on single output models. 9 Derating curve is application specific for ambient temperatures >50 °C, for optimum reliability no part of the heatsink should exceed 90 ºC and no semiconductor case temperature should exceed 100 ºC. 10 Caution Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 11 Three orthogonal axes, random vibration, 10 minute test for each axis. 12 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 13 Recommend a minimum load of 11 W to achieve the design MTBF. See the derating curve on page 14 Power failure detec is optional by including the suffix “P” to the model number. 15 The ‘J’ suffix indicates that these parts are Pb-free RoHS 6/6 compliant. 16 NOTICE Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at to find a suitable alternative.

Transient Response

NFS110-7601PJ V A to 10 A +12 V A to 5 A -12 V A to 1 A -5 V A to 1 A

NFS110-7602PJ

V A to 10 A +24 V A to 3 A +12 V A to 5 A -12 V A to 1 A

NFS110-7604PJ

V A to 10 A +15 V A to 5 A -15 V A to 1 A -5 V A to 1 A

NFS110-7605J V 10 A to 20 A

NFS110-7612J +12 V A to 9 A NFS110-7615J +15 V A to A

NFS110-7624J +24 V A to A
150 mV peak, 1 ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery
150 mV peak, 1 ms recovery 300 mV peak, 1 ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery
150 mV peak, 1 ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery
250 mV peak, 1 ms recovery
360 mV peak, 1 ms recovery
450 mV peak, 1 ms recovery
720 mV peak, 1 ms recovery

Embedded Power for Business-Critical Continuity

AC  J1 mating connector

Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478 or equivalent crimp terminals.
More datasheets: M3436 SL002 | M3436 SL005 | M3436 SL001 | A8295SESTR-T | 572 | NFS110-7602J | NFS110-7604PJ | NFS40-7615J | NFS110-7612J | NFS110-7601J


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NFS110-7624J Datasheet file may be downloaded here without warranties.

Datasheet ID: NFS110-7624J 518837