NFS110 Series
Part | Datasheet |
---|---|
![]() |
NFS110-7602J (pdf) |
Related Parts | Information |
---|---|
![]() |
NFS110-7604PJ |
![]() |
NFS40-7615J |
![]() |
NFS110-7612J |
![]() |
NFS110-7601J |
![]() |
NFS110-7624J |
PDF Datasheet Preview |
---|
Embedded Power for Business-Critical Continuity NFS110 Series Single & Quad output 1 of 5 Total Power 80 - 110 W Input Voltage 85 - 264 Vac 120 - 370 Vdc # of Outputs Single, quad Special Features • x inch package • Overvoltage and short circuit protection • 110 W with 20 CFM • Adjustable outputs • EN55022, EN55011 conducted emissions level B • UL, VDE and CSA safety approvals • CE mark • Available RoHS compliant • 2 year warranty Safety • VDE0805/EN60950/ • IEC950/IEC1010 File No. 10401-3336-0213 • Licence No. 4001467 7 • UL1950 File No. E132002 • CSA C22.2 No. 950 File No. LR41062C Electrical Specifications Output Voltage adjustability: Line regulation Overshoot/undershoot Temperature coefficient Overvoltage protection: Output power limit Minimum output current Short circuit protection: V o/p on multi’s V single output 12 V single output 15 V single output 24 V single output LL to HL, FL All outputs on all units At turn-on All outputs Multi o/p V only V single output 12 V single output 15 V single output 24 V single output Primary power limited See Note 13 Burst mode operation 12 - 14 V 15 - 18 V 24 - 30 V max. ±0.02%/°C V ± V ± V ± V 22 V ± V 33 V ± V Pin max. 160 W Pout min. 110 W 0A Input voltage range: Input frequency range Input surge current Safety ground leakage current: 230 Vac 110 Vac, 50 Hz 230 Vac, 50 Hz 85 - 264 Vac 120 - 370 Vdc 47 - 440 Hz 35 A mA, max. mA, max. All specifications are typical at nominal input, full load at 25 °C unless otherwise stated Embedded Power for Business-Critical Continuity EMC Characteristics Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity General Specifications Hold-up time: Ordering Information Output Voltage Max 1 +12 V V IA +24 V IB 6 +12 V -15 V Output Currents Peak 2 20 A 9A A 20 A 9A A 20 A 9A A Fan 3 10 A 5A 1A 10 A 5A 1A 10 A 5A 1A 9A A 3 of 5 Ripple 4 50 mV 120 mV 120 mV 50 mV 50 mV 240 mV 120 mV 120 mV 50 mV 150 mV 150 mV 50 mV 120 mV 150 mV 240 mV Total Regulation 5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± Model Numbers 13, 15, F NFS110-7601PJ 14 NFS110-7602PJ 6, 14 NFS110-7604PJ 14 NFS110-7612J 7,8 NFS110-7615J 7,8 NFS110-7624J 7,8 Notes 1 Convection cooled, 80 W maximum. 2 Peak outputs lasting less than 60 seconds with duty cycle less than Total peak power must not exceed 110 W. 3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum. 4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth using a 12 inch twisted pair terminated with a 47 µF capacitor. 5 Total regulation is defined as the static output regulation at 25 °C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. 6 To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the following load condition must be true IA / IB 5, where IA = V output current, and IB = +24 V output current The +24 V output will maintain regulation under the following additional condition IA 5 A. 7 Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts natural convection or 110 Watts forced air . 8 Power fail detect not available on single output models. 9 Derating curve is application specific for ambient temperatures >50 °C, for optimum reliability no part of the heatsink should exceed 90 ºC and no semiconductor case temperature should exceed 100 ºC. 10 Caution Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 11 Three orthogonal axes, random vibration, 10 minute test for each axis. 12 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 13 Recommend a minimum load of 11 W to achieve the design MTBF. See the derating curve on page 14 Power failure detec is optional by including the suffix “P” to the model number. 15 The ‘J’ suffix indicates that these parts are Pb-free RoHS 6/6 compliant. 16 NOTICE Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at to find a suitable alternative. Transient Response NFS110-7601PJ V A to 10 A +12 V A to 5 A -12 V A to 1 A -5 V A to 1 A NFS110-7602PJ V A to 10 A +24 V A to 3 A +12 V A to 5 A -12 V A to 1 A NFS110-7604PJ V A to 10 A +15 V A to 5 A -15 V A to 1 A -5 V A to 1 A NFS110-7605J V 10 A to 20 A NFS110-7612J +12 V A to 9 A NFS110-7615J +15 V A to A NFS110-7624J +24 V A to A 150 mV peak, 1 ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery 150 mV peak, 1 ms recovery 300 mV peak, 1 ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery 150 mV peak, 1 ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery 100 mV peak, ms recovery 250 mV peak, 1 ms recovery 360 mV peak, 1 ms recovery 450 mV peak, 1 ms recovery 720 mV peak, 1 ms recovery Embedded Power for Business-Critical Continuity AC J1 mating connector Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478 or equivalent crimp terminals. |
More datasheets: 3385-20-1-0500-010-1-TS | 3385-20-1-0500-011-1-TS | 3385-20-1-0500-004-1-TS | 3385-20-1-0500-001-1-TS | 3385-20-1-0500-006-1-TS | M3436 SL002 | M3436 SL005 | M3436 SL001 | A8295SESTR-T | 572 |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived NFS110-7602J Datasheet file may be downloaded here without warranties.