09-91-0500 UK PINS 08-58-0111 DC Outputs Molex 09-50-8121 USA 09-91-1200 UK PINS 08-58-0111 Remote sense/Power fail Molex 22-01-1022 USA 22-01-1023 UK PINS 08-50-0114 Astec Connector Kit #70-841-008, includes all of the above.
Part | Datasheet |
---|---|
![]() |
70-841-008 (pdf) |
PDF Datasheet Preview |
---|
110 Watts LPQ110 Series Total Power 80-110 Watts Input Voltage 85-264 VAC 120-300 VDC # of Outputs Quad Special Features • Universal input • High efficiency • Remote sense on main output • Built-in EMI filter • Low output ripple • Adjustable 5 V output • Overvoltage protection • Overload protection • Adjustable floating 4th output On LPQ112 and LPQ113 • Power fail • Optional L bracket -B suffix • Cover kit available LPX110-C Environmental Operating temperature 0° to 50°C ambient derate each output at per degree from 50° to 70°C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances G peak 5 Hz to 500 Hz, operational Storage temperature -40° to 85°C Temperature coefficient per °C MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions Electrical Specs Input Input range Frequency Inrush current Input current Efficiency EMI filter Safety ground leakage current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak 115 VAC <36 A peak 230 VAC, cold start 25°C A max. RMS 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted mA 50/60 Hz, 264 VAC input Output Maximum power Adjustment range Cross regulation Hold-up time Overload protection Overvoltage protection 80 W for convection 110 W with 30 CFM forced air ±5% min. on main 5-25 V on 4th output on LPQ112 and LPQ113 ±2% on output 1 ±3% on outputs 2, 3 & 4 20 ms 80 W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected 110-145% above peak rating VDC on main output. Latching type, recycle AC to reset. Logic Control Power Failure Remote sense Electrical Specs VDE UL CSA NEMKO BABT CB CE 0805/EN60950 IEC950 UL1950 CSA Level 3 EN 60950/EMKO-TUE 74-sec 203 EN60950/BS7002 Certificate and report Mark LVD 11774-3336-1245 LC #84997 E132002 LR53982C P94102464 PS/605823 1423, 1424, 1425 102 America’s USA 1-888-41-ASTEC Europe UK 44 1384 842-211 Asia HK 852-2437-9662 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone 760-930-4600 Facsimile 760-930-0698 Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load1 Regulation2 LPQ112 -12 V ±5-25 V 11 A 5A A 3A ±2% ±3% ±5% ±3% LPQ113 -15 V ±5-25 V 11 A 5A A 3A ±2% ±3% ±5% ±3% LPQ114 5V 12 V -12 V 24 V 2A 0A A 11 A 5A A 15 A 9A A 5A ±2% ±3% ±5% +10 / -5% Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a µF capacitor at rated line voltage and load ranges. 4th O/P adjustable 5 to 25 V, factory set at 5 V. Minimum loads are required. Note -B suffix added to model number indicates L bracket option. -B Bracket Ripple P/P PARD 3 50 mV 120 mV 120 mV 240 mV, max. 50 mV 150 mV 150 mV 240 mV, max. 50 mV 120 mV 120 mV 240 mV Pin Assignments |
More datasheets: PM1210-221J-RC | AS1927L-BTDT12M | AS1927L-BTDT-33S | AS1927L-BTDT33X | AS1927L-BTDTR4S | AOD526 | AOD526_DELTA | B88069X2010S102 | B88069X2010T502 | FFPF04S60STU |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived 70-841-008 Datasheet file may be downloaded here without warranties.