Single and dual output

Total Power Input Voltage:
# of Outputs:
30W 9 - 18VDC 36 - 75VDC Single, dual

Special Features
• Designed to meet telecom power supply interface standard ETS300-132-2
• UL, VDE and CSA safety approvals
• VDE0878 and EN55022 conducted emissions level A
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• Fixed frequency operation at 350 kHz
• MTBF in excess of 7,005,000 hours demonstrated
• Basic insulation system
• Available RoHS compliant
• 2 year warranty

The BXA30 series, comprising 9 different models, has been conceived as an applications-specific range of dc-dc converters, specifically addressing telecommunications, industrial electronics, test equipment, mobile telecommunications and distributed power applications. The series offers three wide input voltage ranges, 9 Vdc to 18 Vdc and 36 Vdc to 75 Vdc, and is available in single and dual output versions. Designed to meet ETSI telecoms interface standards ETS300-132-2 and BTR2511, together with internal filtering to EN55022 level A, safety approval to EN60950 and UL1950, and isolation of 1500 Vdc, the 48 Vdc models are ideal for telecommunications applications. The 12 V models are particularly suited to industrial, mobile telecom and test equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity compliant. Other features include low output ripple, overvoltage protection, continuous short circuit protection, remote enable and remote sense.

Safety

VDE0805/EN60950/IEC950 File No. 14501-3336-7006 Licence No. 6231

UL1950 File No. E174104 CSA C22.2 No. 950 File No. LR41062C

Embedded Power for Business-Critical Continuity

Specifications

All specifications are typical at nominal input, full load at 25°C unless otherwise stated.

OUTPUT SPECIFICATIONS

Voltage adjustability

Singles
±10%

Line regulation

LL to HL single/dual

Load regulation

FL to NL single/dual

Ripple and noise 20 MHz bandwidth

V All others All models
60 mV pk-pk 50 mV pk-pk 100 mV pk-pk
20 mV rms

Temperature coefficient
±0.02%/°C

Overvoltage protection Transient
135% Vout

Short circuit protection

Singles Duals single short

Duals dual short

Continuous See BXA15/30 Design Note 100
Ordering Information

INPUT VOLTAGE 9-18 Vdc 36-75 Vdc 36-75 Vdc 36-75 Vdc 36-75 Vdc 36-75 Vdc 36-75 Vdc 36-75 Vdc 36-75 Vdc

OUTPUT VOLTAGE

OUTPUT CURRENT MAX.

INPUT CURRENT 1
100 mA 30 mA 30 mA 30 mA 30 mA 30 mA 30 mA 30 mA 30 mA

TYPICAL EFFICIENCY
80% 75% 81% 80% 85% 87% 80% 84% 86%

REGULATION

LINE 2

LOAD 3

MODEL NUMBER 4,6,14,15 BXA30-12S05J BXA30-48S3V3J BXA30-48S3V3/8J 11 BXA30-48S05J BXA30-48S12J BXA30-48S15J BXA30-48D05J BXA30-48D12J BXA30-48D15J

Notes
1 Nominal, at no load. 2 Low line to high line. 3 Full load to no-load. For duals, the value stated is for balanced loads. 4 An optional internal filter is available, which will meet VDE0871 level A,

Specifications Contd.

Embedded Power for Business-Critical Continuity

BOTTOM

VIEW
Ø 8 Places

Case/Metal Inserts M3.0 Typ. 4 Places

ALL DIMENSIONS IN INCHES mm

Tolerance .XX .XXX

SIDE VIEW

PIN NUMBER 1 2 3 4 5 6 7 8

PIN CONNECTIONS SINGLE OUTPUT
+ Vin + Sense 13 Trim Sense + Vout Remote ON/OFF

DUAL OUTPUT + Vin + Vout

Common Vout No Pin No Pin

Remote ON/OFF

EXTERNAL OUTPUT TRIMMING

Single output models can be 5
externally trimmed by ±10%

TRIM
using either method shown.

TRIM DOWN
10K TRIMPOT

Embedded Power for Business-Critical Continuity

Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone +1 760 930 4600 Facsimile +1 760 930 0698

Europe UK

Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone +44 0 1384 842 211 Facsimile +44 0 1384 843 355
More datasheets: L6R12-070 | L6R12H-070 | L6R12-360 | L6R12H-059 | L6R12H-050 | L6R12H-090 | L6R12H-120 | HFW11R-2STBE1LF | 40370 | AOWF12T60


Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived BXA30-48D05-FJ Datasheet file may be downloaded here without warranties.

Datasheet ID: BXA30-48D05-FJ 518823