SXE15 Series Dual positive output
Part | Datasheet |
---|---|
![]() |
SXE15-48D3V3-2V5R (pdf) |
Related Parts | Information |
---|---|
![]() |
SXE15-48D3V3-2V5 |
![]() |
SXE15-48D05-3V3 |
![]() |
SXE15-48D05-3V3R |
![]() |
SXE15-48D05-3V3J |
PDF Datasheet Preview |
---|
SXE15 Series Dual positive output DC/DC CONVERTERS 15W High Efficiency DC/DC Converters • Two positive outputs • Output voltage tracking • High efficiency • Approved to EN60950, UL/cUL1950 • Wide operating temperature, up to and exceeding 65ºC natural convection • Up to 100% load imbalance • Trim function • No minimum load • Complies with ETS 300 019-1-3/2-3 • Fully compliant with ETS 300 386-1 The SXE15 is a new high efficiency open frame isolated 15 Watt converter series. The first two models in the series feature an input voltage range of 33 to 75VDC and are available in output voltages of 5V/3.3V and 3.3V/2.5V. The output voltage on each model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the models are 86% for the 5V/3.3V and 85% for the 3.3V/2.5V version. The SXE15 series also has a remote on/off capability, with active high or active low logic. Overcurrent and overvoltage protection features are included as standard. With full international safety approval including EN60950 and cUL1950, the SXE15 reduces compliance costs and time to market. All specifications are typical at nominal input, full load at 25°C unless otherwise stated TÜV 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage adjustability Both outputs ±10% min. Voltage setpoint Both outputs ±2% typ. Voltage accuracy See Note 8 Both outputs ±4% max. Output voltage over all line and load conditions Minimum load 5V/3.3V 3.3V/2.5V 4.931V < Vo1 < 5.133V 3.236V < Vo2 < 3.368V 3.297V < Vo1 < 3.431V 2.431V < Vo2 < 2.531V Ripple and noise 20MHz bandwidth 140mV pk-pk max. 50mV rms max. Transient response 50% to 75% to 50% Peak dev. settling time D05-3V3, V01 D05-3V3, V02 D3V3-2V5, V01 D3V3-2V5, V02 To no external cap. 180mV max. 100mVmax. 150mV max. 100mV max. 100µs Short circuit protection 10A rms Isc Continuous automatic recovery Tracking Max. differential 0.7V during start-up INPUT SPECIFICATIONS Input voltage range 48Vin nominal 33 to 75VDC Input current No load Remote OFF 35mA max. 25mA max. |
More datasheets: AWP2-34-7241-T-R | A-MO 6/4 SR | HCPL-800J-500E | HCPL-800J-500 | 59-146UWD/TR8 | FQP3N80 | H-3RV-C | 3125 | 2612 | FFA20U40DNTU |
Notice: we do not provide any warranties that information, datasheets, application notes, circuit diagrams, or software stored on this website are up-to-date or error free. The archived SXE15-48D3V3-2V5R Datasheet file may be downloaded here without warranties.